Voltmeter PCE-DC 25

R 6,610.00

Tax includedShipping calculated at checkout

PCE SKU: PCE-DC 25

Add R 2,000.00 more for FREE shipping!

Shipping
Ships in 5-10 business days

Warranty
2 year standard warranty

DESCRIPTION

Voltmeter with Bluetooth interface / Current measurement 0 ... 1000 A AC/DC / Temperature measurement / NCV test / Clamp opening 34 mm (1.3") / Measuring rate of 3 Hz /
Optionally expandable with Rogowski coil for 3000 A AC / Automatic switch-off

The voltmeter has a measuring range of 0… 1000 A AC/DC. The current is measured inductively using the clamp on the measuring device. Live supply lines with a diameter of up to 32 mm (1.2") can be connected to the clamp meter. With the optional Rogowski coil, the measuring range of the clamp meter can be extended to up to 3000 A AC. The clamp meter has sub-functions for current measurement. The inrush current can be measured with the clamp meter. This is a particularly important function, as motors such as those installed in ventilation systems or hall lighting require a particularly high current when switched on.

In addition to current measurement, the voltmeter can also measure voltages from 0… 1000 V AC/DC, resistances, frequencies and capacitances. The functions can be set using the rotary selector switch on the clamp meter. With the NCV function, the clamp meter can be used to determine the absence of voltage without contact. As soon as a voltage of 150 V AC is applied, this is indicated by an additional red LED. This function is active for every measuring function selected using the rotary selector switch. An LED lamp is integrated in the clamp meter for optimal illumination of the measuring point.

The voltmeter can be connected to an Android or iOS device via the Bluetooth interface. With the free app for the clamp meter, the measured values ​​can be displayed, saved and further processed. The clamp meter thus covers a wide range of measuring tasks due to the multitude of functions.

HIGHLIGHTS

- Measuring range 0 ... 1000 A AC/DC
- Bluetooth interface
- Inrush current measurement
- Not Connected Voltage function
- LC colour display
- Optionally with ISO certificate

SPECIFICATION

DC voltage  
Measuring range 600.0 mV DC
Resolution 0.1 mV DC
Accuracy ±(0.5 % + 8 digits)
   
Measuring range 6.000 V DC
Resolution 0.001 V DC
Accuracy ±(1.5 % + 5 digits)
   
Measuring range 60.00 V DC
Resolution 0.01 V DC
Accuracy ±(1.5 % + 5 digits)
   
Measuring range 600.0 V DC
Resolution 0.1 V DC
Accuracy ±(1.5 % + 5 digits)
   
Measuring range 1000 V DC
Resolution 1 V
Accuracy ±(1.5 % + 5 digits)
   
Input impedance >10 MΩ
Overvoltage protection 1000 V AC/DC
   
AC voltage
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(1.5 % + 5 digits)
   
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(1.5 % + 5 digits)
   
Measuring range 600.0 V AC
Resolution 0.1 V AC
Accuracy ±(1.5 % + 5 digits)
   
Measuring range 1000 V AC
Resolution 1 V AC
Accuracy ±(1.5 % + 5 digits)
   
Peak value (PEAK) accuracy ±10 %
Peak value (PEAK) response time 1 ms
Input impedance >10 MΩ
Overvoltage protection 1000 V AC/DC
   
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Low pass filter (LowZ)
(50 ... 400 Hz)
 
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(3.0 % + 40 digits)
   
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(3.0 % + 40 digits)
   
Measuring range 300.0 V AC
Resolution 0.1 V
Accuracy ±(3.0 % + 40 digits)
   
Input impedance <300 kΩ
Overvoltage protection 1000 V AC/DC
   
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
AC with DC voltage
(50 ... 400 Hz)
 
Measuring range 6.000 V AC
Resolution 0.001 V AC
Accuracy ±(2.5 % + 20 digits)
   
Measuring range 60.00 V AC
Resolution 0.01 V AC
Accuracy ±(2.5 % + 20 digits)
   
Measuring range 600.0 V AC
Resolution 0.1 V AC
Accuracy ±(2.5 % + 20 digits)
   
Measuring range 1000 V AC
Resolution 1 V AC
Accuracy ±(2.5 % + 20 digits)
   
Input impedance >10 MΩ
   
Direct current  
Measuring range 600.0 A DC
Resolution 0.1 A DC
Accuracy ±(2.5 % + 5 digits)
   
Measuring range 1000 A DC
Resolution 1 A DC
Accuracy ±(2.8 % + 5 digits)
   
Overvoltage protection 1000 A DC
   
Alternating current
(50 ... 60 Hz)
 
Measuring range 600.0 A AC
Resolution 0.1 A AC
Accuracy ±(2.5 % + 5 digits)
   
Measuring range 1000 A AC
Resolution 1 A AC
Accuracy ±(2.8 % + 5 digits)
   
Overload protection 1000 A AC/DC
   
Flexible clamp meter
(50 ... 400 Hz)
 
Measuring range 30.00 A AC
Resolution 0.01 A AC
Accuracy ±(3.0 % + 5 digits)
   
Measuring range 300.0 A AC
Resolution 0.1 A AC
Accuracy ±(3.0 % + 5 digits)
   
Measuring range 3000 A AC
Resolution 1 A AC
Accuracy ±(3.0 % + 5 digits)
   
Overload protection 3000 A AC/DC
   
The accuracy relates to a measuring range of 10 ... 100 %
with a sine wave.
Resistance  
Measuring range 600.0 Ω
Resolution 0.1 Ω
Accuracy ±(1.0 % + 10 digits)
   
Measuring range 6.000 kΩ
Resolution 0.001 kΩ
Accuracy ±(1.5 % + 5 digits)
   
Measuring range 60.00 kΩ
Resolution 0.01 kΩ
Accuracy ±(1.5 % + 5 digits)


Measuring range 600.0 kΩ
Resolution 0.1 kΩ
Accuracy ±(1.5 % + 5 digits)
   
Measuring range 6.000 MΩ
Resolution 0.001 MΩ
Accuracy ±(2.5 % + 5 digits)
   
Measuring range 60.00 MΩ
Resolution 0.01 MΩ
Accuracy ±(3.5 % + 10 digits)
   
Overvoltage protection 1000 V AC/DC


Continuity test  
Signal <50 Ω
Overvoltage protection 1000 V AC/DC
   
Diode test
Test current <1.5 mA
Maximum tension when open
circuit
3.3 V DC
   
Frequency measurement  
Measuring range 9.999 Hz ... 99.99 kHz
Resolution 0.01 ... 10 Hz
Accuracy ±(1.2 % + 5 digits)
   
Overvoltage protection 1000 V AC/DC
   
Sensitivity >5 Vrms with one duty cycle
   from 20 ... 80 %
Duty cycle  
Measuring range 10.0 ... 90.0 %
Resolution 0.1 %
Accuracy ±(1.2 % + 8 digits)
   
Pulse range 40 Hz ... 10 kHz
Pulse amplitude ±5 V (0.1 ... 100 ms)
   
Capacity  
Measuring range 60.00 nF
Resolution 0.01 nF
Accuracy ±(4.0 % + 20 digits)
   
Measuring range 600.0 nF
Resolution 0.1 nF
Accuracy ±(3.0 % + 8 digits)
   
Measuring range 6.000 µF
Resolution 0.001 µF
Accuracy ±(3.0 % + 8 digits)


Measuring range 60.00 µF
Resolution 0.01 µF
Accuracy ±(3.0 % + 8 digits)
   
Measuring range 600.0 µF
Resolution 0.1 µF
Accuracy ±(3.0 % + 8 digits)
   
Measuring range 6000 µF
Resolution 1 µF
Accuracy ±(5.0 % + 8 digits)
   
Measuring range 60.00 mF
Resolution 0.01 mF
Accuracy ±(5.0 % + 20 digits)
   
Measuring range 100.0 mF
Resolution 0.1 mF
Accuracy ±(5.0 % + 20 digits)
   
Overvoltage protection 1000 V AC/DC
   
Temperature measurement
(Thermocouple Type K)
 
Measuring range -40 ... 600.0 °C
Resolution 0.1 °C
Accuracy ±(1.5 % + 5 digits)
   
Measuring range 600 ... 1000 °C
Resolution 1 °C
Accuracy ±(1.5 % + 5 digits)
   
Measuring range -40 ... 600.0 °F
Resolution 0.1 °F
Accuracy ±(1.5 % + 9 digits)
   
Measuring range 600 ... 1800 °F
Resolution 1 °F
Accuracy ±(1.5 % + 9 digits)
   
Overvoltage protection 1000 V AC/DC
   
The accuracy refers to the measuring device without temperature probe.
Specifications refer to a stable ambient condition of ±1 °C.
If the measurement lasts for a long time, the measured value increases by 2 °C
   
Further specifications  
Clamp opening
34 mm / 1.3"
NCV >150 V AC
Display LC colour display
Display when measuring range exceeded   "OL" (overload)
Measuring rate 3 measured values per second
Interface Bluetooth
Operating conditions 5 ... 40 °C / 41 ... 104 °F
  <80 % RH non-condensing at
  31 °C / 87 °F linearly decreasing to 50 % RH
  non-condensing at 40 °C / 104 °F
Storage conditions -20 ... 40 °C / -4 ... 140 °F <80 % RH
   non-condensing
Maximum working height 2000 m / 7000 ft
Power supply 3 x 1.5 V AAA batteries
Auto power off Switched off, 15, 30, 45, 60 minutes
Dimensions 250 x 80 x 40 mm / 9.8 x 3.1 x 1.5"
Weight 365 g / 12.8 oz

DELIVERY SCOPE

1 x Voltmeter PCE-DC 25
1 x Pair of test leads
1 x Type K thermocouple
1 x Thermocouple adapter
3 x 1.5 V AAA batteries
1 x Transport bag
1 x Instruction manual

PDF Specification Sheet - Download Here

Shipping: 5-10 business days