DESCRIPTION
Clamp meter with Bluetooth 4.0 interface / Measuring range 0 ... 1500 V AC/DC /
Expandable with additional flexible current clamp for measurements up to 3000 A AC /
Inrush current measurement / VFD function / Incl. ISO calibration certificate
Expandable with additional flexible current clamp for measurements up to 3000 A AC /
Inrush current measurement / VFD function / Incl. ISO calibration certificate
The clamp meter is the ideal measuring device for measuring voltages up to 1500 V AC/DC and currents up to 1000 A AC/DC. The current measurement with the clamp meter is inductive. To do this, the supply line is placed in the clamp meter. This has the particular advantage that the current can be measured during operation. This means that the clamp meter is used, for example, for maintenance work on a photovoltaic system. Photovoltaic systems consist of many different solar cells that are connected in series with one another. Here, the current clamps can be used to measure the individual currents of individual rows in order to limit possible errors.
In addition to normal voltage and current measurements, the clamp meter can also measure the inrush current. Inrush currents are currents that are particularly high when the device is switched on. These currents arise when motors start up for ventilation systems, for example, or when stadium lighting is switched on. This measurement with the clamp meter is particularly important for dimensioning the supply line and fuses. Frequency converters are converters that output the voltage on the primary side with a changed frequency and amplitude on the secondary side. With the clamp meter and the VFD measurement function, measurements can be carried out up to a frequency of 45 Hz ... 1 kHz.
The clamp meter also has a Bluetooth 4.0 interface. With this interface on the clamp meter, a connection to an Android and iOS device can be established. With the free “Meterbox Pro” app, the values measured by the clamp meter can be displayed and saved for later analysis.
With the data logging function, the clamp meter can save all measured values at any set interval. After a measurement, the values can be graphically displayed using the clamp meter. Each individual measuring point can also be read individually from the clamp meter. The storage capacity of the clamp meter has a size of 16 groups and a total storage capacity of 100,000 measured values. With the clamp meter, the measured value is saved with the date and time.
The clamp meter can be expanded with an optional current clamp. The additional current clamp to the clamp meter is flexible and can therefore be adapted to the measuring task. With the extended clamp-on ammeter, current measurements of up to 3000 A AC can be carried out. The flexible current clamp is connected to the voltage input of the clamp meter. The current clamp converts the voltage value into a usable current value and shows it on the display.
Because of its many different functions and the high measuring range, the clamp meter is used, for example, for checking photovoltaic systems, hydroelectric power plants, wind power plants or for installing immovable electrical machines. The clamp meter is equipped with an ISO calibration certificate.
In addition to normal voltage and current measurements, the clamp meter can also measure the inrush current. Inrush currents are currents that are particularly high when the device is switched on. These currents arise when motors start up for ventilation systems, for example, or when stadium lighting is switched on. This measurement with the clamp meter is particularly important for dimensioning the supply line and fuses. Frequency converters are converters that output the voltage on the primary side with a changed frequency and amplitude on the secondary side. With the clamp meter and the VFD measurement function, measurements can be carried out up to a frequency of 45 Hz ... 1 kHz.
The clamp meter also has a Bluetooth 4.0 interface. With this interface on the clamp meter, a connection to an Android and iOS device can be established. With the free “Meterbox Pro” app, the values measured by the clamp meter can be displayed and saved for later analysis.
With the data logging function, the clamp meter can save all measured values at any set interval. After a measurement, the values can be graphically displayed using the clamp meter. Each individual measuring point can also be read individually from the clamp meter. The storage capacity of the clamp meter has a size of 16 groups and a total storage capacity of 100,000 measured values. With the clamp meter, the measured value is saved with the date and time.
The clamp meter can be expanded with an optional current clamp. The additional current clamp to the clamp meter is flexible and can therefore be adapted to the measuring task. With the extended clamp-on ammeter, current measurements of up to 3000 A AC can be carried out. The flexible current clamp is connected to the voltage input of the clamp meter. The current clamp converts the voltage value into a usable current value and shows it on the display.
Because of its many different functions and the high measuring range, the clamp meter is used, for example, for checking photovoltaic systems, hydroelectric power plants, wind power plants or for installing immovable electrical machines. The clamp meter is equipped with an ISO calibration certificate.
HIGHLIGHTS
- Free app for Android and iOS
- Measuring range 0 ... 1500 V AC/DC
- Data logging for up to 100,000 measured values
- Inrush current measurement
- Additionally with LowZ voltage measurement
- 2.36" TFT display
- With voltage and temperature measurement
- Incl. calibration certificate
- Measuring range 0 ... 1500 V AC/DC
- Data logging for up to 100,000 measured values
- Inrush current measurement
- Additionally with LowZ voltage measurement
- 2.36" TFT display
- With voltage and temperature measurement
- Incl. calibration certificate
SPECIFICATION
DC voltage | |
Measuring range | ±600.0 mV |
Resolution | 0.1 mV |
Accuracy | ±(0.8 % of measured value + 8 digits) |
Measuring range | ±6.000 V |
Resolution | 0.001 V |
Accuracy | ±(0.5 % of measured value + 5 digits) |
Measuring range | ±60.00 V |
Resolution | 0.01 V |
Accuracy | ±(0.5 % of measured value + 5 digits) |
Measuring range | ± 600.0 V |
Resolution | 0.1 V |
Accuracy | ±(0.8 % of measured value + 5 digits) |
Measuring range | ±1500 V |
Resolution | 1 V |
Accuracy | ±(0.8 % of measured value + 5 digits) |
Input impedance: >10 MΩ; Overvoltage protection: 1500 VDC / 1000 VAC rms | |
AC voltage | |
Measuring range | 0.000 ... 6.000 V |
Resolution | 0.001 V |
Accuracy | 50 ... 60 Hz: ±(1.2 % of measured value + 5 digits) |
61 ... 1 kHz: ±(2.5 % of measured value + 5 digits) | |
Measuring range | 0.00 ... 60.00 V |
Resolution | 0.01 V |
Accuracy | 50 ... 60 Hz: ±(1.2 % of measured value + 5 digits) |
61 ... 1 kHz: ±(2.5 % of measured value + 5 digits) | |
Measuring range | 0.0 ... 600.0 V |
Resolution | 0.1 V |
Accuracy | 50 ... 60 Hz: ±(1.2 % of measured value + 5 digits) |
61 ... 1 kHz: ±(2.5 % of measured value + 5 digits) | |
Measuring range | 0 ... 1500 V |
Resolution | 1 V |
Accuracy | 50 ... 60 Hz: ±(1.2 % of measured value + 5 digits) |
61 ... 1 kHz: ±(2.5 % of measured value + 5 digits) | |
The accuracy relates to 10 ... 100% of the respective measuring range and a sine wave input impedance: >9 MΩ; Overvoltage protection: 1000 V DC/AC RMS The accuracy of the "PEAK" function is: ±10 % of measured value The response time of the "PEAK" function is: 1 ms |
|
AC voltage with low input impedance (LowZ) | |
Measuring range | 0.000 ... 6.000 V |
Resolution | 0.001 V |
Accuracy | ±(3.0 % of measured value + 40 digits) |
Measuring range | 0.00 ... 60.00 V |
Resolution | 0.01 V |
Accuracy | ±(3.0 % of measured value + 40 digits) |
Measuring range | 0.0 ... 300.0 V |
Resolution | 0.1 V |
Accuracy | ±(3.0 % of measured value + 40 digits) |
Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS The accuracy relates to 10 ... 100% of the respective measuring range and a sine wave |
|
DC and AC voltage (50 ... 1 kHz) | |
Measuring range | 0.000 ... 6.000 V |
Resolution | 0.001 V |
Accuracy | ±(2.5 % of measured value + 40 digits) |
Measuring range | 0.00 ... 60.00 V |
Resolution | 0.01 V |
Accuracy | ±(2.5 % of measured value + 40 digits) |
Measuring range | 0.0 ... 600.0 V |
Resolution | 0.1 V |
Accuracy | ±(2.5 % of measured value + 40 digits) |
Measuring range | 0 ... 1000 V |
Resolution | 1 V |
Accuracy | ±(2.5 % of measured value + 40 digits) |
Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS | |
DC and AC voltage with low input impedance (LowZ) | |
Measuring range | 0.000 ... 6.000 V |
Resolution | 0.001 V |
Accuracy | ±(3.5 % of measured value + 40 digits) |
Measuring range | 0.00 ... 60.00 V |
Resolution | 0.01 V |
Accuracy | ±(3.5 % of measured value + 40 digits) |
Measuring range | 0.0 ... 300.0 V |
Resolution | 0.1 V |
Accuracy | ±(3.5 % of measured value + 40 digits) |
Input impedance: 300 kΩ; Overvoltage protection: 1000 VDC / VAC RMS | |
Non-Contacting Voltage Verification (NCV) | |
Detection range | 100 ... 1000 AC/DC |
Direct current | |
Measuring range | ±60.00 A |
Resolution | 0.01 A |
Accuracy | ±(3.0 % of measured value + 8 digits) |
Measuring range | ±600.0 A |
Resolution | 0.1 A |
Accuracy | ±(3.0 % of measured value + 8 digits) |
Measuring range | ±1000 A |
Resolution | 1 A |
Accuracy | ±(3.0 % of measured value + 8 digits) |
Overload protection: 1000 A AC/DC | |
Alternating current (50 ... 60 Hz) | |
Measuring range | 0.00 ... 60.00 A |
Resolution | 0.01 A |
Accuracy | ±(2.5 % of measured value + 5 digits) |
Measuring range | 0.0 ... 600.0 A |
Resolution | 0.1 A |
Accuracy | ±(2.5 % of measured value + 5 digits) |
Measuring range | 0 ... 1000 A |
Resolution | 1 A |
Accuracy | ±(2.5 % of measured value + 5 digits) |
Overload protection: 1000 A AC/DC The accuracy relates to 10 ... 100 % of the respective measuring range and a sine wave The inrush current measurement is for reference only |
|
AC current measurement with flexible clamp meter (50 ... 400 Hz) | |
Measuring range | 0.00 ... 30.00 A |
Resolution | 0.01 A |
Accuracy | ±(3.0 % of measured value + 5 digits) |
Measuring range | 0.0 ... 300.0 A |
Resolution | 0.1 A |
Accuracy | ±(3.0 % of measured value + 5 digits) |
Measuring range | 0 ... 3000 A |
Resolution | 1 A |
Accuracy | ±(3.0 % of measured value + 5 digits) |
Overload protection: 1000 A AC/DC The accuracy relates to 10 ... 100% of the respective measuring range and a sine wave |
|
Resistance and continuity measurement | |
Measuring range | 0.0 ... 600.0 Ω |
Resolution | 0.1 Ω |
Accuracy | ±(1.0 % of measured value + 10 digits) |
Measuring range | 0.000 ... 6.000 kΩ |
Resolution | 0.001 kΩ |
Accuracy | ±(0.8 % of measured value + 5 digits) |
Measuring range | 0.00 ... 60.00 kΩ |
Resolution | 0.01 kΩ |
Accuracy | ±(0.8 % of measured value + 5 digits) |
Measuring range | 0.0 ... 600.0 kΩ |
Resolution | 0.1 kΩ |
Accuracy | ±(0.8 % of measured value + 5 digits) |
Measuring range | 0.000 ... 6.000 MΩ |
Resolution | 0.001 MΩ |
Accuracy | ±(0.8 % of measured value + 5 digits) |
Measuring range | 0.00 ... 60.00 MΩ |
Resolution | 0.01 MΩ |
Accuracy | ±(2.5 % of measured value + 10 digits) |
Continuity test acoustic signal at: <50 Ω Overvoltage protection: 1000 V AC/DC |
|
Frequency measurement | |
Measuring range | 0.00 ... 60.00 Hz |
Resolution | 0.01 Hz |
Accuracy | ±(0.2 % of measured value + 5 digits) |
Measuring range | 0.0 ... 600.0 Hz |
Resolution | 0.1 Hz |
Accuracy | ±(0.2 % of measured value + 5 digits) |
Measuring range | 0.000 ... 6.000 kHz |
Resolution | 0.001 kHz |
Accuracy | ±(0.2 % of measured value + 5 digits) |
Measuring range | 0.00 ... 60.00 kHz |
Resolution | 0.01 kHz |
Accuracy | ±(0.2 % of measured value + 5 digits) |
Measuring range | 0.0 ... 600.0 kHz |
Resolution | 0.1 kHz |
Accuracy | ±(0.2 % of measured value + 5 digits) |
Measuring range | 0.000 ... 6.000 MHz |
Resolution | 0.001 MHz |
Accuracy | ±(0.2 % of measured value + 5 digits) |
Overvoltage protection: 1000 V AC/DC Sensitivity: >2 Vrms with a duty cycle between 20 ... 80 % and a frequency of <100 kHz >5 Vrms with a duty cycle between 20 ... 80 % and a frequency of >100 kHz |
|
Duty cycle | |
Measuring range | 10.0 ... 90.0 % |
Resolution | 0.1 % |
Accuracy | ±(1.2 % of measured value + 8 digits) |
Frequency range: 40 ... 10 kHz; Pulse amplitude ±5 V with a duration between 100 µs ... 100 mS |
|
Capacity | |
Measuring range | 0.00 ... 60.00 nF |
Resolution | 0.01 nF |
Accuracy | ±(3.0 % of measured value + 20 digits) |
Measuring range | 0.0 ... 600.0 nF |
Resolution | 0.1 nF |
Accuracy | ±(3.0 % of measured value + 8 digits) |
Measuring range | 0.000 ... 6.000 µF |
Resolution | 0.001 µF |
Accuracy | ±(3.0 % of measured value + 8 digits) |
Measuring range | 0.00 ... 60.00 µF |
Resolution | 0.01 µF |
Accuracy | ±(3.0 % of measured value + 8 digits) |
Measuring range | 0.0 ... 600.0 nF |
Resolution | 0.1 nF |
Accuracy | ±(3.0 % of measured value + 8 digits) |
Measuring range | 0 ... 6000 µF |
Resolution | 1 µF |
Accuracy | ±(3.5 % of measured value + 20 digits) |
Measuring range | 0.00 ... 60.00 mF |
Resolution | 0.01 mF |
Accuracy | for reference only |
Measuring range | 0.0 ... 600.0 mF |
Resolution | 0.1 mF |
Accuracy | for reference only |
Overvoltage protection: 1000 A AC/DC | |
Temperature measurement thermocouple Type K (connection) | |
Measuring range | -40.0 ... 600.0 °C |
Resolution | 0.1 °C |
Accuracy | ±(1.5 % of measured value + 3 °C) |
Measuring range | 600 ... 1000 °C |
Resolution | 1 °C |
Accuracy | ±(1.5 % of measured value + 3 °C) |
Measuring range | -40.0 ... 600.0 °F |
Resolution | 0.1 °F |
Accuracy | ±(1.5 % of measured value + 5.4 °F) |
Measuring range | 600 ... 1800 °F |
Resolution | 1 °F |
Accuracy | ±(1.5 % of measured value + 5.4 °F) |
Measuring range | 245.0 ... 600.0 K |
Resolution | 0.1 K |
Accuracy | ±(1.5 % of measured value + 3 K) |
Measuring range | 600 ... 1273 K |
Resolution | 1 K |
Accuracy | ±(1.5 % of measured value + 3 K) |
Overvoltage protection: 1000 A AC/DC | |
Diode test | |
Test current | <1.5 mA |
Maximum voltage | 3.3 VDC |
Further specifications | |
Storage space | 16 groups with a total storage space |
of 100,000 measured values | |
Clamp diameter horizontal | 38 mm / 1.49" |
Clamp diameter vertical | 63 mm / 2.48" |
Clamp opening | 45 mm / 1.77" |
Protection class | IP65 |
Interface | Bluetooth 4.0 |
Pollution degree | 2 |
Insulation categories | CAT IV 600 V, CAT III 1000 V, CAT II 1500 V |
Maximum working height | 2000 m / 6562 ft |
Power supply battery | 7.4 V, 1200 mAh Li-ion battery |
Power supply charger | Primary: 100 ... 240 V AC, 50 ... 60 Hz |
Secondary: 12 V DC, 2 A | |
Plug connection charger | Europa, USA, England, China |
Battery status display | available |
Automatic switch-off | switched off, 15, 30 or 60 minutes |
Display | 2.36" TFT |
Display frequency | 3 Hz |
Reference conditions | 18 ... 28 °C, 64 ... 82 °F; <80 % RH, |
non-condensing | |
Dimensions | 275 x 100 x 45 mm / 10.8 x 3.9 x 1.7" |
Weight | 481 g / 16.9 oz |
DELIVERY SCOPE
1 x Clamp meter PCE-CTI 10-ICA
1 x Thermocouple Type-K with adapter
1 x Pair of measuring leads
1 x Carrying case
1 x Battery charging station
1 x Rechargeable battery
1 x Instruction manual
1 x ISO Calibration Certificate
1 x Thermocouple Type-K with adapter
1 x Pair of measuring leads
1 x Carrying case
1 x Battery charging station
1 x Rechargeable battery
1 x Instruction manual
1 x ISO Calibration Certificate