Description
TOMLIN INSTRUMENTS TMI-MP-504 laminated flux indicator strips confirm field direction and that the field, particles, technique and viewing conditions can produce an indication.
Type G suits general industrial work; Type A is a finer, more sensitive version for aerospace and critical parts.
Features
- Pack of 5 strips
- About 50 × 12 × 0.15 mm per strip
- Three-layer laminate with soft magnetic core
- Three parallel artificial indications
- Wet fluorescent, wet visible and dry methods
- Reusable with care
Specifications
| Model | TMI-MP-504 |
| Pack size | 5 strips |
| Strip size | Approx. 50 × 12 × 0.15 mm |
| Indications | Three parallel |
| Types | Type G (general purpose), Type A (aerospace) |
| Indication | Qualitative |
Ordering: TMI-MP-504-01 – Flux indicator strips, Type G, pack of 5; TMI-MP-504-02 – Flux indicator strips, Type A, pack of 5
Strips give a qualitative indication only. They do not measure field strength and do not replace a calibrated field meter.
Industries Used In
- Checking field direction during MPI
- Confirming adequate magnetisation
- Procedure set-up and operator training
- Weld, casting and forging inspection