Personal Noise Dosimeter Badge AWA5920 media thumbnails
Personal Noise Dosimeter Badge AWA5920-1
Personal Noise Dosimeter Badge AWA5920-2

Personal Noise Dosimeter Badge AWA5920

R 26,650.00

Tax includedShipping calculated at checkout

AIHUA SKU: AWA5920-1

Model Variants: Option 1 – Single Kit

Shipping
Ships in 5-10 business days

Warranty
1 year standard warranty

AWA5920 Wearable Personal Noise Dosimeter

The AWA5920 is a compact wearable noise dosimeter designed for professional occupational and personal noise exposure assessment.

Worn directly by the worker, the AWA5920 measures noise exposure throughout a shift and calculates key parameters including TWA, LEX,8h, LAVG, Dose, SEL and Leq. It also provides statistical analysis, data logging and audio recording, with optional 1/1 and 1/3 octave analysis for more detailed investigation of workplace noise.

With up to 64 GB storage, more than 41 hours battery life and IP65 protection, the AWA5920 is suited to occupational hygienists, health and safety professionals and organisations carrying out workplace noise exposure surveys.

Key Features

  • IEC 61252:2025 personal noise dosimeter
  • IEC 61672-1:2013 Class 2 sound level meter performance
  • IEC 61260-1:2014 Class 2 octave filters
  • Measures TWA, LEX,8h, LAVG, Dose and sound exposure
  • Leq, Peak and statistical Ln measurements
  • 51–142 dBA measurement range
  • Up to 145 dBC Peak
  • A, C and Z frequency weighting
  • Fast, Slow and Impulse time weighting
  • Statistical noise analysis
  • Data logging / time history
  • 64 GB data storage
  • High-quality WAV audio recording
  • Optional 1/1 octave analysis
  • Optional 1/3 octave analysis
  • Multiple measurement modules can operate simultaneously
  • 1.3" 240 × 240 TFT display
  • USB Type-C charging and data transfer
  • Optional Bluetooth and 4G
  • IP65 dust and water resistance
  • More than 41 hours continuous operation
  • Compact 119 g wearable design

Choose Your AWA5920 Configuration

Configuration Best For Main Capability
Option 1 – Single Kit Standard personal and occupational noise exposure surveys TWA/Dose • Leq/Peak • Statistical Ln • Logging • Recording
Option 2 – Single Kit + Octave Analysis Detailed individual exposure and frequency investigation Standard functions + 1/1 & 1/3 Octave
Option 3 – 5-Pack Monitoring multiple workers during the same survey Five-dosimeter professional monitoring package
Option 4 – 5-Pack + Class 2 Calibrator Multi-worker surveys with field calibration capability Five-dosimeter package + Class 2 acoustic calibrator
Option 5 – 5-Pack + Octave Analysis + Calibrator Advanced multi-worker occupational noise surveys Five dosimeters + 1/1 & 1/3 Octave + Class 2 calibrator

These five configurations correspond directly to the packages in Aihua's current 2026 price list. All include Leq/Peak, Ln statistics, TWA/Dose, logging, storage and recording; octave analysis is included in Options 2 and 5, while a sound calibrator is included in Options 4 and 5.

Option 1 – Single Kit

The standard choice for individual workplace noise exposure measurement.

The worker wears the compact AWA5920 throughout the measurement period while the instrument continuously records and calculates occupational noise exposure.

Measurements include:

  • TWA
  • LEX,8h
  • LAVG
  • Noise Dose
  • Personal sound exposure
  • Leq
  • Peak levels
  • Statistical Ln values
  • Data logging
  • Audio recording

Ideal for routine occupational hygiene and workplace noise surveys.

Option 2 – Single Kit + Octave Analysis

Adds real-time 1/1 and 1/3 octave frequency analysis to the standard dosimeter functions.

This is useful where it is not enough to establish how much noise a worker is exposed to — you also need to determine which frequencies are responsible for that exposure.

Ideal for:

  • Engineering noise control
  • Hearing-protection investigations
  • Machinery noise
  • Noise-source identification
  • Detailed occupational hygiene surveys

Option 3 – 5-Pack

Designed for surveys where multiple employees or work positions need to be monitored simultaneously.

A five-dosimeter system allows exposure measurements to be collected from multiple workers during the same shift, making it particularly useful for larger occupational hygiene programmes.

Option 4 – 5-Pack + Class 2 Calibrator

Adds a Class 2 acoustic calibrator to the multi-instrument system, allowing the dosimeters to be field checked before and after measurements.

The supplier's five-pack calibrator kit includes five AWA5920 dosimeters, one sound calibrator and a five-unit charging dock with power supply.

Option 5 – 5-Pack + Octave Analysis + Calibrator

The most comprehensive AWA5920 package.

It combines:

  • Five wearable dosimeters
  • Leq / Peak and statistical analysis
  • TWA / Dose measurement
  • Data logging
  • Audio recording
  • 1/1 octave analysis
  • 1/3 octave analysis
  • Class 2 sound calibrator

Ideal for professional occupational hygiene teams carrying out advanced multi-worker exposure surveys.

Occupational Noise Measurement

The AWA5920 measures the key parameters required for personal noise exposure assessment.

Parameter Measurement
TWA Time-weighted average sound pressure level
LEX,8h 8-hour equivalent sound pressure level
LAVG Average sound pressure level
DOSE Noise dose percentage
E Personal sound exposure
SEL Sound Exposure Level
Leq,T Equivalent continuous sound level
Lpeak Peak sound pressure level
Ln Statistical percentile noise levels

Exchange rate can be selected from 2, 3, 4, 5 or 6, with selectable threshold levels from 40–90 dB and criterion levels from 70–90 dB.

Octave Analysis

Optional Class 2 frequency analysis provides both:

1/1 Octave

Nine bands from:

31.5 Hz to 8 kHz

1/3 Octave

Detailed frequency analysis from:

20 Hz to 12.5 kHz

Both modes provide real-time Lp, Lmax, Lmin and Leq,T measurements with simultaneous A, C and Z weighted analysis.

Data Logging & Audio Recording

The AWA5920 includes 64 GB storage and can save measurement results for later PC analysis.

Audio recording is stored in WAV format with selectable recording quality up to 48 kHz / 32 bit, allowing recorded noise events to be reviewed after the survey.

Measurement data can be transferred directly to a computer using the USB Type-C interface.

Optional Accessories & Add-ons

Accessory / Option Purpose
AWA6022A Class 2 Sound Calibrator Field calibration and verification
1/1 Octave Analysis Real-time octave frequency analysis
1/3 Octave Analysis Detailed real-time frequency analysis
5-Unit Charging Dock Simultaneous charging for multi-dosimeter systems
USB Type-C Cable Charging and measurement-data transfer
Bluetooth Module Optional wireless communication
4G Module Optional mobile data communication
Replacement Windscreen Reduces wind influence on measurements
Carrying Case Instrument protection and transport

Standard Single Kit

The standard single-instrument package includes:

  • AWA5920 noise dosimeter
  • Charger
  • USB cable
  • Carrying case


Technical Specifications

Specification Details
Instrument Type Personal / Occupational Noise Dosimeter
Dosimeter Standard IEC 61252:2025
Sound Level Standard IEC 61672-1:2013 Class 2
Octave Filter Standard IEC 61260-1:2014 Class 2
A-Weighted Measurement Range 51–142 dBA
C-Weighted Measurement Range 51–142 dBC
Z-Weighted Measurement Range 56–142 dBZ
C-Weighted Peak Range 68–145 dBC
Frequency Range 20 Hz–12.5 kHz
Sound Exposure Range 0.01–999.99 Pa²h
Noise Dose Range 0–99,999%
Frequency Weighting A, C, Z
Time Weighting F, S, I
A/D Resolution 24 bit
Sampling Frequency 48 kHz
Display 1.3" TFT-LCD, 240 × 240
Storage 64 GB
Interface USB Type-C
Wireless Communication Optional 4G and Bluetooth
Battery 3.7 V, 2000 mAh lithium
Battery Life More than 41 hours under specified conditions
Charging Time Approx. 8 hours
Measurement Duration 1 second to 99 hours
Protection Rating IP65
Dimensions 90 × 49 × 64 mm
Weight Approx. 119 g
Operating Temperature -10°C to +40°C
Operating Humidity 20–90% RH
Atmospheric Pressure 65–108 kPa

The measurement ranges, battery, environmental limits and physical specifications above are taken from the current June 2026 manual.

Typical Applications

  • Occupational noise exposure assessment
  • Personal noise dosimetry
  • Full-shift workplace noise monitoring
  • Industrial hygiene
  • Health and safety surveys
  • Hearing conservation programmes
  • Manufacturing environments
  • Construction sites
  • Machinery and equipment noise
  • Mining and heavy industry
  • Transport and vehicle noise
  • Impulse noise assessment
  • Multi-worker exposure surveys
  • Engineering noise-control investigations

Sound Level Meters

Model Accuracy Variants / Analysis Available Best For / Why Choose It
AWA5636 Class 2 Basic • Integrating / Leq • Online Monitoring • Statistical + TWA/Dose General workplace, machinery and environmental noise. Lowest-cost professional option.
AWA5662 Class 1 Integrating • Statistical • TWA/Dose • 1/1 + 1/3 Octave • Low/High SPL versions Professional Class 1 noise measurement. Best-value Class 1 option.
AWA6228+ Class 1 Integrating • Statistical • 1/1 Octave • 1/3 Octave • FFT • Reverberation • Logger • Recording • Dosimeter • GPS Professional and advanced noise measurement. Configure only the functions you need.
AWA6292 Class 1 Integrating • Statistical • TWA/Dose • 1/1 Octave • 1/3 Octave • Reverberation • STI Advanced environmental and architectural acoustics. Highest acoustic capability.


The AWA5636 is the best starting point where Class 2 accuracy is suitable.

Step up to the AWA5662 when Class 1 accuracy is required while keeping the instrument straightforward and cost-effective.

Choose the AWA6228+ where greater configuration flexibility or advanced functions such as FFT, reverberation, detailed frequency analysis or GPS are required.

The AWA6292 is intended for more specialised acoustic applications including advanced frequency analysis, reverberation and STI measurement.

Specialist Instruments

Model Type Versions / Configurations Best For Why Choose It
AWA5920 Noise Dosimeter Single • Multi-unit kits Personal and occupational noise exposure Wearable shift monitoring
YT2001 Acoustic Imager Standard Leak detection, partial discharge and sound-source location Visually locate sound sources

Not sure which model you need? Send us your application, required measurement parameters or applicable standard and our applications team can recommend the most suitable instrument and configuration.

Shipping: 5-10 business days