TOMLIN INSTRUMENTS TMI-HY-101 ATP fluorescence detector (hygiene luminometer)
TOMLIN INSTRUMENTS TMI-HY-101 photo 2
TOMLIN INSTRUMENTS TMI-HY-101 photo 3
TOMLIN INSTRUMENTS TMI-HY-101 photo 4
ATP Fluorescence Detector (Hygiene Luminometer) – TMI-HY-101-5
TOMLIN INSTRUMENTS TMI-HY-101 photo 6
ATP Fluorescence Detector (Hygiene Luminometer) – TMI-HY-101-7

ATP Fluorescence Detector (Hygiene Luminometer) – TMI-HY-101

R 13,560.00

Tax includedShipping calculated at checkout

TOMLIN Instruments SKU: TMI-HY-101-01

Model: TMI-HY-101-01 – standard precision

Delivery
8–14 working days

Warranty
1 year standard warranty

Ask us about this product

Send your question to our team. Your selected product details are included automatically.

ATP Fluorescence Detector (Hygiene Luminometer) – TMI-HY-101 TMI-HY-101-01 – standard precision TMI-HY-101-01

Description

The TOMLIN INSTRUMENTS TMI-HY-101 measures ATP on surfaces and in liquids as a fast check of cleaning effectiveness. It is used in food and beverage plants, pharmaceutical and medical settings, water treatment, papermaking, and inspection and quarantine work.

Two models share the 0 – 9,999 RLU range and ≤ 1.0 CFU/ml detection limit. TMI-HY-101-01 offers standard precision (1 × 10⁻¹⁵ mol ATP). TMI-HY-101-02 offers ten times higher precision (1 × 10⁻¹⁶ mol ATP), with a sealed bottom-reading chamber, ≤ 1 RLU background and storage for more than 3,000 results.


Features

  • Detection range 0 – 9,999 RLU (both models)
  • Detection limit ≤ 1.0 CFU/ml (both models)
  • Fecal coliform ≥ 1 × 10⁻⁶ CFU (both models)
  • TMI-HY-101-02: sealed chamber with bottom detection
  • TMI-HY-101-02: background ≤ 1 RLU for trace ATP
  • TMI-HY-101-02: RLU or coliform screening mode
  • TMI-HY-101-02: stores more than 3,000 results
  • TMI-HY-101-02: results transferable to a PC

Specifications

Testing time 1 – 60 s
Testing interference ±2 % or ±2 RLU
Background value ≤ 1 RLU
Storage More than 3,000 results
Operating temperature 0 – 40 °C
Relative humidity 20 – 85 %
Power supply 2 × 1.5 V AA batteries
Size (W × H × D) 199 × 76 × 37 mm
Weight 265 g with batteries

Model comparison

Parameter TMI-HY-101-01 TMI-HY-101-02
Precision 1 × 10⁻¹⁵ mol ATP 1 × 10⁻¹⁶ mol ATP
Detection limit ≤ 1.0 CFU/ml ≤ 1.0 CFU/ml
Detection range 0 – 9,999 RLU 0 – 9,999 RLU
Fecal coliform ≥ 1 × 10⁻⁶ CFU ≥ 1 × 10⁻⁶ CFU

The specifications table describes TMI-HY-101-02; for TMI-HY-101-01 the model comparison values apply. TMI-HY-101-02 reference levels: below 30 RLU pass, above 100 RLU fail, 30 – 100 RLU in between.

Industries Used In

  • Food and beverage hygiene monitoring
  • Pharmaceutical and medical cleaning verification
  • Water treatment checks
  • Inspection and quarantine

TMI-HY-101-02 is supplied with main unit and carrying case; test swabs and a data cable with software are optional.

Delivery: 8–14 working days