Overview
The GWD200-10t is a wireless tension dynamometer for crane, rigging, pull-test and suspended-load measurement up to 10 tonnes. A separate handheld indicator lets the operator read and control the load link from a safer working position.
Key Features
- Supplier-published accuracy: ±0.05% of full scale
- Wireless working distance: at least 80 m; optional configuration up to 200 m
- Zero, tare, peak hold, overload warning, setpoints and gravity adjustment
- Selectable kg, t, lb, N and kN units
- 125% safe overload and 400% ultimate load rating
- RS-232 output and supplied handheld display
Applications
- Crane and hoist load checks
- Rigging and lifting-equipment verification
- Pull testing and structural load measurement
- Industrial maintenance and commissioning
Specifications
| Model | GWD200-10t |
|---|---|
| Capacity | 0–10,000 kg / 0–100 kN |
| Division | 5 kg / 50 N |
| Accuracy | ±0.05% FS (supplier published) |
| Material | Alloy steel |
| Display | 25 mm LCD on load link; 12 mm LCD on handheld indicator |
| Wireless range | ≥80 m standard; up to 200 m optional |
| Wireless frequency | 2.4 GHz standard; 433 MHz or 868 MHz optional |
| Stabilisation time | ≤5 seconds |
| Safe / ultimate load | 125% / 400% of rated capacity |
| Operating conditions | -20 to +50 °C; ≤85% RH at 20 °C |
| Battery | 3 × AA (load link); 4 × AA (indicator) |
| Battery life | ≥50 hours |
| Dimensions | A 320 × B 120 × C 57 × D 230 mm; Ø 92 mm; H 535 mm |
| Load-link weight | 10.4 kg |
| Weight with shackles | 24.8 kg |
Standards and Compliance
Performance values above are supplier published. A model-specific declaration of conformity and serial-numbered calibration evidence should be confirmed for the supplied unit. This instrument is for load measurement and is not approved for lifting people. All lifting and rigging work remains subject to the applicable site procedures and statutory requirements.
Included Accessories
- Wireless handheld indicator
- G2130 shackles
- Remote control
- Carry case
Optional Accessories
- Extended wireless-range configuration
- 433 MHz or 868 MHz wireless configuration
- Traceable calibration service, subject to capacity and laboratory confirmation