Class 1 Professional Sound Level Meter AWA5662 media thumbnails
Class 1 Professional Sound Level Meter AWA5662-1
Class 1 Professional Sound Level Meter AWA5662-2
Class 1 Professional Sound Level Meter AWA5662-3

Class 1 Professional Sound Level Meter AWA5662

R 18,460.00

Tax includedShipping calculated at checkout

AIHUA SKU: AWA5662-1

Model Variants: Option 1 – Integrating

Shipping
Ships in 5-10 business days

Warranty
1 year standard warranty

AWA5662 Class 1 Multifunction Sound Level Meter

The AWA5662 is a professional Class 1 multifunction sound level meter designed for environmental, workplace, industrial and machinery noise measurement.

It provides a cost-effective step up from Class 2 instruments for users who require Class 1 accuracy without necessarily needing the broader modular capabilities of higher-end acoustic analysers.

Choose from integrating, statistical and real-time octave-analysis configurations, with specialist versions also available for occupational noise exposure and unusually low or high sound pressure levels.

Key Features

  • IEC 61672 Class 1 sound level meter
  • Standard measurement range: 25–140 dB(A)
  • Integrating Leq / Peak measurement
  • Statistical Ln analysis available
  • TWA / Noise Dose measurement available
  • Real-time 1/1 and 1/3 octave analysis available
  • Time-history data logging
  • Audio recording
  • 4 GB internal memory
  • Supports up to 64 GB TF card
  • Bluetooth on selected configurations
  • Optional mini printer on selected configurations
  • Specialist low and high sound pressure versions available
  • Professional Class 1 performance in a compact handheld instrument

Choose Your AWA5662 Configuration

Configuration Best For Included Functions
Option 1 – Integrating General professional Class 1 noise measurement Integrating + Time-History Logging + Recording + Bluetooth
Option 3 – Statistical Environmental, community and industrial noise surveys Integrating + Statistical Ln + Logging + Recording + Bluetooth
Option 7 – RTA + Statistical Advanced environmental and noise-source investigation Integrating + Statistical + 1/1 & 1/3 Octave + Logging + Recording

All three configurations include measurement storage with 4 GB internal memory and support for a 64 GB TF card.

Option 1 – Integrating

The most cost-effective entry into the AWA5662 platform.

Designed for professional users requiring Class 1 integrating sound level measurement for general noise surveys.

Includes:

  • Integrating Leq / Peak measurement
  • Time-history data logging
  • Audio recording
  • 4 GB internal memory
  • Support for 64 GB TF card
  • Bluetooth

Suitable for:

  • Machinery and equipment noise
  • Workplace measurements
  • Factory and industrial noise
  • Environmental surveys
  • Boundary noise measurement
  • General professional Class 1 sound level surveys

Integrating measurement allows average sound levels such as Leq to be measured over a defined period rather than relying only on instantaneous sound pressure levels.

Option 3 – Statistical

Recommended for environmental and community noise applications where the distribution of sound levels over time is important.

This configuration includes:

  • Integrating Leq / Peak measurement
  • Statistical Ln analysis
  • Time-history data logging
  • Audio recording
  • 4 GB internal memory
  • Support for 64 GB TF card
  • Bluetooth

Suitable for:

  • Environmental noise surveys
  • Community noise
  • Traffic noise
  • Construction noise
  • Industrial boundary measurements
  • Long-duration noise assessment
  • Workplace noise investigations

Statistical Ln measurements are particularly useful where percentile noise levels are required in addition to Leq.

Option 7 – RTA + Statistical

The most capable of our standard AWA5662 configurations.

This version combines:

  • Integrating measurement
  • Statistical Ln analysis
  • Real-time 1/1 octave analysis
  • Real-time 1/3 octave analysis
  • Time-history data logging
  • Audio recording
  • 4 GB internal memory
  • Support for 64 GB TF card

The octave analyzers allow the user to identify which frequency bands are contributing to the measured noise.

Suitable for:

  • Noise-source identification
  • Machinery noise investigation
  • Engineering noise control
  • Environmental acoustic investigations
  • Industrial noise troubleshooting
  • Frequency spectrum analysis
  • Advanced environmental surveys

Other AWA5662 Configurations Available

The AWA5662 can also be supplied in other factory configurations for more specialised applications.

Configuration Main Functions Best For
Option 1 – Integrating Integrating + Logging / Recording + Bluetooth General Class 1 measurements
Option 2 – Integrating + Printer Integrating + Logging / Recording + Bluetooth + Mini Printer Field measurements requiring printed results
Option 3 – Statistical Integrating + Statistical + Logging / Recording + Bluetooth Environmental and community noise
Option 4 – TWA / Dose TWA / Dose + Logging / Recording Occupational noise exposure
Option 5 – Statistical + Printer Integrating + Statistical + Logging / Recording + Bluetooth + Mini Printer Environmental surveys requiring printed results
Option 6 – RTA Integrating + 1/1 & 1/3 Octave + Logging / Recording Frequency and noise-source analysis
Option 7 – RTA + Statistical Integrating + Statistical + 1/1 & 1/3 Octave + Logging / Recording Advanced environmental and frequency analysis
Option 8 – High SPL Integrating + Logging / Recording with specialist high-level microphone High and ultra-high sound pressure measurement
Option 9 – Low SPL Integrating + Logging / Recording with low-noise microphone Quiet environments and low-level acoustics

Occupational Noise / TWA & Dose

Option 4 is designed specifically for occupational and workplace noise exposure measurement.

This configuration provides TWA / Dose measurement together with time-history logging and recording.

Suitable for:

  • Occupational hygiene
  • Workplace noise exposure assessment
  • Industrial health and safety
  • Shift-based exposure measurements
  • Professional occupational noise surveys

1/1 & 1/3 Octave Analysis

Options 6 and 7 provide real-time spectrum analysis using both:

  • 1/1 octave bands
  • 1/3 octave bands

These functions allow the frequency content of a noise source to be investigated rather than measuring only its overall sound level.

Typical applications include:

  • Machinery noise
  • Industrial acoustics
  • Noise-source identification
  • Engineering noise control
  • Environmental investigations
  • Acoustic troubleshooting

Option 6 provides octave analysis without statistical analysis.

Option 7 combines octave analysis with statistical Ln measurements and is therefore the better choice for advanced environmental noise work.

High Sound Pressure Measurement

The AWA5662 can be supplied with specialist microphone configurations for measurements beyond the standard 25–140 dB(A) range.

High SPL

Measurement range:

48–163 dB(A)

Suitable for:

  • Heavy industrial equipment
  • Engines and turbines
  • High-output machinery
  • Motorsport
  • High-level product testing
  • Very loud acoustic sources

Ultra-High SPL

Measurement range:

62–174 dB(A)

Designed for exceptionally high sound pressure applications where conventional sound level meter microphones would exceed their measurement range.

Suitable for:

  • Extreme industrial noise
  • High-energy acoustic testing
  • Explosive or impulse-type noise investigations
  • Very high-output machinery
  • Specialist engineering applications

Low Sound Pressure Measurement

The specialist low-level AWA5662 configuration extends the measurement capability down to:

16–131 dB(A)

Suitable for:

  • Quiet rooms
  • Low-noise machinery
  • Product noise testing
  • Laboratory acoustics
  • Building services noise
  • Background noise investigations
  • Low-level environmental sound measurement

A specialist low-noise microphone is used to achieve the lower measurement range.

Time-History Logging & Recording

AWA5662 configurations include time-history data logging and recording functionality.

This allows measurement results to be stored over time rather than recording only a final result.

Suitable for:

  • Long-duration noise measurements
  • Machinery investigations
  • Environmental surveys
  • Noise-event investigation
  • Workplace noise monitoring

Measurement storage includes:

  • 4 GB internal memory
  • Support for up to 64 GB TF card

Data Storage & Connectivity

Depending on configuration, the AWA5662 provides:

  • 4 GB internal memory
  • Up to 64 GB TF card support
  • Time-history measurement storage
  • Audio recording
  • USB communication
  • Signal outputs
  • Bluetooth on selected configurations
  • Optional mini printer

Optional Accessories & Add-ons

Accessory / Option Purpose
Class 1 Sound Calibrator Professional field calibration and verification
Tripod Stable hands-free and longer-duration measurements
Microphone Extension Cable Remote positioning of the measurement microphone
64 GB TF Card Expanded measurement and recording storage
Mini Printer Immediate printing of field measurement results on compatible configurations
Replacement Windscreen Reduces wind interference during outdoor measurement
Low-Level Microphone Configuration Extends measurement down to 16 dB(A)
High-Level Microphone Configuration Extends measurement up to 163 dB(A)
Ultra-High-Level Microphone Configuration Extends measurement up to 174 dB(A)

Technical Specifications

Specification Details
Instrument Type Class 1 Multifunction Sound Level Meter
Accuracy Class IEC 61672 Class 1
Standard Measurement Range 25–140 dB(A)
Low-Level Configuration 16–131 dB(A)
High-Level Configuration 48–163 dB(A)
Ultra-High-Level Configuration 62–174 dB(A)
Standard Microphone AWA14425
Frequency Weighting A, C, Z
Integrating Measurement Leq / Peak
Statistical Analysis Available depending on configuration
Frequency Analysis Optional real-time 1/1 and 1/3 octave
Time-History Logging Included
Audio Recording Included
Internal Storage 4 GB
Expandable Storage Supports up to 64 GB TF card
Bluetooth Included on selected configurations
Mini Printer Available on selected configurations

Typical Applications

  • Environmental noise measurement
  • Workplace noise surveys
  • Occupational noise assessment
  • Machinery and equipment noise
  • Factory and industrial noise
  • Industrial hygiene
  • Community noise
  • Traffic noise
  • Construction noise
  • Boundary noise surveys
  • Long-duration noise monitoring
  • Noise-source identification
  • 1/1 octave analysis
  • 1/3 octave analysis
  • Engineering noise control
  • High sound pressure measurement
  • Ultra-high sound pressure measurement
  • Low-level acoustic measurement
  • Acoustic consultancy

Sound Level Meters

Model Accuracy Main Capability Best For
AWA5636 Class 2 General and integrating sound level measurement Lowest-cost professional option where Class 2 is sufficient
AWA5662 Class 1 Integrating, statistical, TWA / Dose, octave and specialist SPL configurations Best-value professional Class 1 platform
AWA6228+ Class 1 Highly configurable with octave, FFT, recording, GPS and specialist analysis Advanced users who need greater configuration flexibility
AWA6292 Class 1 New-generation environmental and acoustic analysis platform with modern connectivity, audio, reverberation and STI Advanced environmental consultants and architectural acoustics

Choose the AWA5636 where Class 2 accuracy is sufficient and cost is the primary consideration.

Choose the AWA5662 when Class 1 accuracy is required and you want a straightforward, cost-effective professional instrument.

Choose the AWA6228+ where advanced configurable functions such as FFT, GPS or specialist analysis are required.

Choose the AWA6292 for the latest Aihua platform and advanced environmental monitoring, architectural acoustics, modern connectivity and STI applications.

Specialist Instruments

Model Type Best For
AWA5920 Noise Dosimeter Personal and occupational noise exposure monitoring
YT2001 Acoustic Imager Leak detection, partial discharge and sound-source location

Not sure which model you need? Send us your application, required measurement parameters or applicable standard and our applications team can recommend the most suitable instrument and configuration.

Shipping: 5-10 business days