Class 1 Sound Level Meter Kit with Calibrator AWA5662 media thumbnails
Class 1 Sound Level Meter Kit with Calibrator AWA5662-1
Class 1 Sound Level Meter Kit with Calibrator AWA5662-2
Class 1 Sound Level Meter Kit with Calibrator AWA5662-3
Class 1 Sound Level Meter Kit with Calibrator AWA5662-4
Class 1 Sound Level Meter Kit with Calibrator AWA5662-5
Class 1 Sound Level Meter Kit with Calibrator AWA5662-6
Class 1 Sound Level Meter Kit with Calibrator AWA5662-7

Class 1 Sound Level Meter Kit with Calibrator AWA5662

R 35,350.00

Tax includedShipping calculated at checkout

AIHUA SKU: AWA5662 - Kit

Shipping
Ships in 5-10 business days

Warranty
1 year standard warranty

AWA5662 Class 1 Professional Noise Measurement Kit

The AWA5662 Class 1 Professional Noise Measurement Kit provides a complete system for professional environmental, workplace, industrial and consulting noise surveys.

Built around the AWA5662 Statistical Class 1 Sound Level Meter, the kit combines integrating sound level measurement, statistical Ln analysis, time-history data logging and audio recording with an AWA6021A Class 1 Sound Calibrator and AWA8814 professional tripod.

This makes it an excellent choice for users who require Class 1 accuracy and professional statistical noise measurement without the additional cost or complexity of advanced frequency-analysis equipment.

Complete Class 1 Measurement Kit

Included Equipment Purpose
AWA5662 Statistical Class 1 Sound Level Meter Integrating and statistical environmental noise measurement
Statistical Ln Analysis Percentile noise analysis for environmental and variable noise
Time-History Data Logging Records how measured noise changes throughout the survey
Audio Recording Provides recorded audio for later review and investigation
AWA6021A Class 1 Sound Calibrator Class 1 field calibration and verification at 94 / 114 dB
AWA8814 Professional Tripod Stable and repeatable positioning during field measurements
Windscreen Reduces wind influence during outdoor measurements
Carrying Case Protects equipment during storage and transport
USB Data Connection Measurement transfer to a computer

Why Choose the Professional Class 1 Kit?

This kit is designed for users who require more than a basic sound level reading.

The AWA5662 Statistical configuration measures conventional integrating parameters such as Leq while also providing statistical Ln measurements, time-history logging and audio recording.

Statistical analysis is particularly valuable when noise varies over time and a single average level does not provide the complete picture.

The included Class 1 calibrator allows field verification before and after a survey, while the tripod provides consistent positioning during professional measurements.

Suitable for:

  • Environmental consultants
  • Acoustic consultants
  • Occupational hygienists
  • Health and safety professionals
  • Industrial facilities
  • Engineering companies
  • Environmental officers
  • Universities and research facilities
  • Professional testing organisations

AWA5662 Statistical Class 1 Sound Level Meter

The AWA5662 is a professional IEC Class 1 sound level meter designed for environmental, workplace and industrial noise measurement.

The Statistical configuration supplied in this kit includes:

  • Integrating Leq / Peak measurement
  • Statistical Ln analysis
  • Time-history data logging
  • Audio recording
  • 4 GB internal memory
  • Support for up to 64 GB TF card
  • Bluetooth communication
  • USB data connection

Main Measurements

Measurement capabilities include:

  • Lp
  • Leq
  • Lmax
  • Lmin
  • SEL
  • Peak sound levels
  • Statistical Ln values
  • Time-history measurement data

Statistical Noise Analysis

Environmental noise often changes considerably throughout a measurement period.

Statistical Ln measurements show the sound level exceeded for a specified percentage of the measurement period and provide additional information beyond a single Leq value.

Common statistical parameters such as L10, L50 and L90 can help characterise:

  • Background noise
  • Typical ambient noise
  • Intermittent noise events
  • Traffic noise
  • Community noise
  • Industrial noise
  • Changing environmental noise conditions

This makes the AWA5662 Statistical configuration particularly suitable for professional environmental and community noise surveys.

Time-History Data Logging

The AWA5662 records measurement data over time, allowing the user to review how noise conditions changed during the survey.

This is useful for:

  • Long-duration environmental measurements
  • Traffic noise surveys
  • Industrial boundary measurements
  • Machinery operating cycles
  • Construction noise
  • Intermittent noise events
  • Workplace investigations

Stored measurement data can be transferred to a computer for further review and analysis.

Audio Recording

The Statistical configuration also provides audio recording capability.

Audio recording is useful when measurement data shows a significant noise event and the user needs additional information to identify its likely source.

Typical applications include:

  • Noise complaint investigations
  • Environmental surveys
  • Construction noise
  • Community noise
  • Machinery investigations
  • Intermittent industrial noise

Key Specifications

Specification Details
Instrument Type Class 1 Multifunction Sound Level Meter
Accuracy IEC 61672-1:2013 Class 1
Configuration Integrating + Statistical
Standard Measurement Range 25–140 dB(A)
Frequency Range 10 Hz–20 kHz
Standard Microphone AWA14425
Frequency Weighting A, C, Z
Time Weighting F, S, I, I10
Statistical Analysis Ln percentile analysis
Time-History Logging Included
Audio Recording Included
Internal Storage 4 GB
Expandable Storage Supports up to 64 GB TF card
Display 2.4" colour display
Communication USB, Bluetooth
Power Supply Battery or external power

AWA6021A Class 1 Sound Calibrator

The included AWA6021A provides Class 1 field calibration and verification of the sound level meter.

The calibrator complies with IEC 60942:2017 Class 1 and provides two selectable calibration levels:

  • 94 dB @ 1 kHz
  • 114 dB @ 1 kHz

Sound pressure level accuracy is ±0.25 dB.

The AWA6021A also incorporates automatic atmospheric pressure compensation to help maintain stable output under changing field conditions.

A field calibration check can be performed before and after a professional noise survey to verify that the measurement system has remained stable.

AWA8814 Professional Tripod

The included AWA8814 professional tripod provides stable and repeatable positioning during noise measurements.

Using a tripod helps:

  • Maintain consistent measurement height and position
  • Reduce movement during measurements
  • Reduce handling of the instrument
  • Improve repeatability between surveys
  • Support longer-duration measurements
  • Provide a stable setup for environmental field work

Data Storage & Transfer

The AWA5662 Statistical configuration provides substantial storage for professional measurements.

  • 4 GB internal memory
  • Support for up to 64 GB TF card
  • Time-history measurement storage
  • Audio recording
  • USB data transfer
  • Bluetooth communication

This allows large amounts of measurement information to be stored in the field and transferred for later analysis.

Typical Applications

  • Environmental noise surveys
  • Community noise assessment
  • Traffic noise
  • Industrial boundary noise
  • Factory noise
  • Construction noise
  • Workplace noise surveys
  • Machinery and equipment noise
  • Occupational hygiene
  • Noise complaint investigations
  • Long-duration noise measurements
  • Professional acoustic consulting
  • Engineering noise investigations
  • Environmental compliance surveys
  • Research and education

Need Frequency Analysis?

This kit is designed primarily for Class 1 integrating and statistical noise measurement.

If you also need to determine which frequency bands are contributing to the measured noise, consider the AWA6228+ Advanced Class 1 Noise Analysis Kit, which adds real-time 1/1 octave frequency analysis and a remote microphone measurement system.

The AWA5662 itself can also be supplied in configurations with 1/1 and 1/3 octave analysis where a more compact frequency-analysis solution is preferred.

Help Me Choose

Professional Noise Measurement Kits

Kit Accuracy Main Measurement Capability Best For
AWA5636 Professional Kit Class 2 Integrating / Leq + calibrator + tripod Workplace, machinery and general noise surveys
AWA5662 Professional Kit Class 1 Integrating + Statistical Ln + Logging + Recording + calibrator + tripod Environmental, consulting and professional Class 1 surveys
AWA6228+ Advanced Kit Class 1 Statistical + 24-Hour Monitoring + Logging + 1/1 Octave + calibrator + remote microphone system Engineering and advanced environmental noise analysis

Class 2 or Class 1?

Choose the AWA5636 Professional Kit when Class 2 accuracy is appropriate and keeping the overall system cost low is important.

Choose the AWA5662 Professional Kit when you require Class 1 accuracy, statistical Ln analysis and professional environmental noise measurement.

Choose the AWA6228+ Advanced Kit when you also require octave frequency analysis for identifying and investigating noise sources.

Not sure which kit you need? Send us your application, required measurement parameters or applicable standard and our applications team can recommend the most suitable system.

Shipping: 5-10 business days