{"product_id":"semi-automatic-kjeldahl-nitrogen-analyzer-protein-nitrogen-testing-system-akn-01","title":"Semi Automatic Kjeldahl Nitrogen Analyzer – Protein \u0026 Nitrogen Testing System AKN-01","description":"\u003ch2 data-start=\"128\" data-end=\"152\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"154\" data-end=\"536\"\u003eThe \u003cstrong data-start=\"158\" data-end=\"228\"\u003eBIOBASE Semi Automatic Kjeldahl Nitrogen Analyzer AKN-01 \/ AKN-01S\u003c\/strong\u003e is a reliable and efficient solution for nitrogen and protein determination using the classical Kjeldahl method. Designed for laboratory precision and operational safety, this system combines automated distillation, intelligent monitoring, and dual operating modes to streamline nitrogen analysis workflows.\u003c\/p\u003e\n\u003cp data-start=\"538\" data-end=\"909\"\u003eWith a 7-inch high-resolution LCD display, users can monitor the entire experimental process in real time. The instrument supports both manual and automatic modes, allowing flexible operation depending on laboratory requirements. The AKN-01S model offers enhanced automation, including automatic drainage and reagent bottle liquid level detection for improved efficiency.\u003c\/p\u003e\n\u003cp data-start=\"911\" data-end=\"1100\"\u003eSuitable for laboratories in food, agriculture, environmental monitoring, and quality control, this factory-direct BIOBASE analyzer ensures accurate, repeatable, and safe nitrogen analysis.\u003c\/p\u003e\n\u003cp data-start=\"1102\" data-end=\"1125\"\u003eDelivery within 7 days.\u003c\/p\u003e\n\u003chr data-start=\"1127\" data-end=\"1130\"\u003e\n\u003ch2 data-start=\"1132\" data-end=\"1149\"\u003eKey Features\u003c\/h2\u003e\n\u003cul data-start=\"1151\" data-end=\"2067\"\u003e\n\u003cli data-start=\"1151\" data-end=\"1238\"\u003e\n\u003cp data-start=\"1153\" data-end=\"1238\"\u003e\u003cstrong data-start=\"1153\" data-end=\"1191\"\u003e7-inch High-Resolution LCD Display\u003c\/strong\u003e – Real-time monitoring and intuitive control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1239\" data-end=\"1316\"\u003e\n\u003cp data-start=\"1241\" data-end=\"1316\"\u003e\u003cstrong data-start=\"1241\" data-end=\"1274\"\u003eManual \u0026amp; Automatic Dual Modes\u003c\/strong\u003e – Flexible operation based on lab needs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1317\" data-end=\"1428\"\u003e\n\u003cp data-start=\"1319\" data-end=\"1428\"\u003e\u003cstrong data-start=\"1319\" data-end=\"1361\"\u003eAutomatic Reagent Addition (Auto Mode)\u003c\/strong\u003e – Precise dosing of lye, boric acid solution, and dilution water\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1429\" data-end=\"1524\"\u003e\n\u003cp data-start=\"1431\" data-end=\"1524\"\u003e\u003cstrong data-start=\"1431\" data-end=\"1465\"\u003eProgrammable Distillation Time\u003c\/strong\u003e – Adjustable from 0–60 minutes with end-of-process alarm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1525\" data-end=\"1629\"\u003e\n\u003cp data-start=\"1527\" data-end=\"1629\"\u003e\u003cstrong data-start=\"1527\" data-end=\"1560\"\u003eWater-Saving Condenser Design\u003c\/strong\u003e – Low water consumption (1.5 L\/min) with real-time flow monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1630\" data-end=\"1777\"\u003e\n\u003cp data-start=\"1632\" data-end=\"1777\"\u003e\u003cstrong data-start=\"1632\" data-end=\"1662\"\u003eAdvanced Safety Protection\u003c\/strong\u003e – Safety door protection, flow rate detection, liquid level alarm, over-temperature and over-pressure protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1778\" data-end=\"1874\"\u003e\n\u003cp data-start=\"1780\" data-end=\"1874\"\u003e\u003cstrong data-start=\"1780\" data-end=\"1816\"\u003eEmergency Stop \u0026amp; Fault Detection\u003c\/strong\u003e – Sound and light alarm with intelligent display system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1875\" data-end=\"1977\"\u003e\n\u003cp data-start=\"1877\" data-end=\"1977\"\u003e\u003cstrong data-start=\"1877\" data-end=\"1907\"\u003eHigh-Performance PTFE Pump\u003c\/strong\u003e – Corrosion-resistant, anti-crystallization, stable liquid handling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1978\" data-end=\"2067\"\u003e\n\u003cp data-start=\"1980\" data-end=\"2067\"\u003e\u003cstrong data-start=\"1980\" data-end=\"2008\"\u003eDurable ABS Construction\u003c\/strong\u003e – Corrosion-resistant, waterproof, and leak-proof design\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2069\" data-end=\"2072\"\u003e\n\u003ch2 data-start=\"2074\" data-end=\"2091\"\u003eApplications\u003c\/h2\u003e\n\u003cp data-start=\"2093\" data-end=\"2149\"\u003eWidely used for nitrogen and protein determination in:\u003c\/p\u003e\n\u003cul data-start=\"2151\" data-end=\"2442\"\u003e\n\u003cli data-start=\"2151\" data-end=\"2183\"\u003e\n\u003cp data-start=\"2153\" data-end=\"2183\"\u003eFood processing laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2184\" data-end=\"2214\"\u003e\n\u003cp data-start=\"2186\" data-end=\"2214\"\u003eFeed production facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2215\" data-end=\"2235\"\u003e\n\u003cp data-start=\"2217\" data-end=\"2235\"\u003eTobacco industry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2236\" data-end=\"2256\"\u003e\n\u003cp data-start=\"2238\" data-end=\"2256\"\u003eAnimal husbandry\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2257\" data-end=\"2288\"\u003e\n\u003cp data-start=\"2259\" data-end=\"2288\"\u003eSoil and fertilizer testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2289\" data-end=\"2317\"\u003e\n\u003cp data-start=\"2291\" data-end=\"2317\"\u003eEnvironmental monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2318\" data-end=\"2343\"\u003e\n\u003cp data-start=\"2320\" data-end=\"2343\"\u003eAgricultural research\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2344\" data-end=\"2380\"\u003e\n\u003cp data-start=\"2346\" data-end=\"2380\"\u003eScientific research institutions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2381\" data-end=\"2406\"\u003e\n\u003cp data-start=\"2383\" data-end=\"2406\"\u003eTeaching laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2407\" data-end=\"2442\"\u003e\n\u003cp data-start=\"2409\" data-end=\"2442\"\u003eQuality supervision departments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2444\" data-end=\"2464\"\u003eAlso suitable for:\u003c\/p\u003e\n\u003cul data-start=\"2466\" data-end=\"2575\"\u003e\n\u003cli data-start=\"2466\" data-end=\"2493\"\u003e\n\u003cp data-start=\"2468\" data-end=\"2493\"\u003eAmmonium salt detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2494\" data-end=\"2533\"\u003e\n\u003cp data-start=\"2496\" data-end=\"2533\"\u003eVolatile fatty acid\/alkali analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2534\" data-end=\"2575\"\u003e\n\u003cp data-start=\"2536\" data-end=\"2575\"\u003eSoil cation exchange capacity testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2577\" data-end=\"2580\"\u003e\n\u003ch2 data-start=\"2582\" data-end=\"2611\"\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2613\" data-end=\"3632\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2613\" data-end=\"2641\"\u003e\n\u003ctr data-start=\"2613\" data-end=\"2641\"\u003e\n\u003cth data-start=\"2613\" data-end=\"2621\" data-col-size=\"sm\" class=\"\"\u003eModel\u003c\/th\u003e\n\u003cth data-start=\"2621\" data-end=\"2630\" data-col-size=\"md\" class=\"\"\u003eAKN-01\u003c\/th\u003e\n\u003cth data-start=\"2630\" data-end=\"2641\" data-col-size=\"md\" class=\"\"\u003eAKN-01S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2674\" data-end=\"3632\"\u003e\n\u003ctr data-start=\"2674\" data-end=\"2733\"\u003e\n\u003ctd data-start=\"2674\" data-end=\"2692\" data-col-size=\"sm\"\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd data-start=\"2692\" data-end=\"2712\" data-col-size=\"md\"\u003e0.1 mg ~ 240 mg N\u003c\/td\u003e\n\u003ctd data-start=\"2712\" data-end=\"2733\" data-col-size=\"md\"\u003e0.1 mg ~ 240 mg N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2734\" data-end=\"2769\"\u003e\n\u003ctd data-start=\"2734\" data-end=\"2750\" data-col-size=\"sm\"\u003eRecovery Rate\u003c\/td\u003e\n\u003ctd data-start=\"2750\" data-end=\"2759\" data-col-size=\"md\"\u003e≥99.5%\u003c\/td\u003e\n\u003ctd data-start=\"2759\" data-end=\"2769\" data-col-size=\"md\"\u003e≥99.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2770\" data-end=\"2843\"\u003e\n\u003ctd data-start=\"2770\" data-end=\"2786\" data-col-size=\"sm\"\u003eSample Amount\u003c\/td\u003e\n\u003ctd data-start=\"2786\" data-end=\"2814\" data-col-size=\"md\"\u003eSolid ≤6 g; Liquid ≤20 mL\u003c\/td\u003e\n\u003ctd data-start=\"2814\" data-end=\"2843\" data-col-size=\"md\"\u003eSolid ≤6 g; Liquid ≤20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2844\" data-end=\"2900\"\u003e\n\u003ctd data-start=\"2844\" data-end=\"2865\" data-col-size=\"sm\"\u003eDistillation Speed\u003c\/td\u003e\n\u003ctd data-start=\"2865\" data-end=\"2882\" data-col-size=\"md\"\u003e3–6 min\/sample\u003c\/td\u003e\n\u003ctd data-start=\"2882\" data-end=\"2900\" data-col-size=\"md\"\u003e3–6 min\/sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2901\" data-end=\"2944\"\u003e\n\u003ctd data-start=\"2901\" data-end=\"2921\" data-col-size=\"sm\"\u003eDistillation Time\u003c\/td\u003e\n\u003ctd data-start=\"2921\" data-end=\"2932\" data-col-size=\"md\"\u003e0–60 min\u003c\/td\u003e\n\u003ctd data-start=\"2932\" data-end=\"2944\" data-col-size=\"md\"\u003e0–60 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2945\" data-end=\"2978\"\u003e\n\u003ctd data-start=\"2945\" data-end=\"2961\" data-col-size=\"sm\"\u003eRepeatability\u003c\/td\u003e\n\u003ctd data-start=\"2961\" data-end=\"2969\" data-col-size=\"md\"\u003e≤0.5%\u003c\/td\u003e\n\u003ctd data-start=\"2969\" data-end=\"2978\" data-col-size=\"md\"\u003e≤0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2979\" data-end=\"3032\"\u003e\n\u003ctd data-start=\"2979\" data-end=\"3007\" data-col-size=\"sm\"\u003eCooling Water Consumption\u003c\/td\u003e\n\u003ctd data-start=\"3007\" data-end=\"3019\" data-col-size=\"md\"\u003e1.5 L\/min\u003c\/td\u003e\n\u003ctd data-start=\"3019\" data-end=\"3032\" data-col-size=\"md\"\u003e1.5 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3033\" data-end=\"3093\"\u003e\n\u003ctd data-start=\"3033\" data-end=\"3050\" data-col-size=\"sm\"\u003eOperating Mode\u003c\/td\u003e\n\u003ctd data-start=\"3050\" data-end=\"3071\" data-col-size=\"md\"\u003eAutomatic \/ Manual\u003c\/td\u003e\n\u003ctd data-start=\"3071\" data-end=\"3093\" data-col-size=\"md\"\u003eAutomatic \/ Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3094\" data-end=\"3183\"\u003e\n\u003ctd data-start=\"3094\" data-end=\"3115\" data-col-size=\"sm\"\u003eAutomatic Drainage\u003c\/td\u003e\n\u003ctd data-start=\"3115\" data-end=\"3119\" data-col-size=\"md\"\u003e—\u003c\/td\u003e\n\u003ctd data-start=\"3119\" data-end=\"3183\" data-col-size=\"md\"\u003eAutomatic emptying \u0026amp; cleaning of digestive tube waste liquid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3184\" data-end=\"3228\"\u003e\n\u003ctd data-start=\"3184\" data-end=\"3217\" data-col-size=\"sm\"\u003eReagent Bottle Level Detection\u003c\/td\u003e\n\u003ctd data-start=\"3217\" data-end=\"3221\" data-col-size=\"md\"\u003e—\u003c\/td\u003e\n\u003ctd data-start=\"3221\" data-end=\"3228\" data-col-size=\"md\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3229\" data-end=\"3264\"\u003e\n\u003ctd data-start=\"3229\" data-end=\"3247\" data-col-size=\"sm\"\u003eReagent Bottles\u003c\/td\u003e\n\u003ctd data-start=\"3247\" data-end=\"3255\" data-col-size=\"md\"\u003e4 pcs\u003c\/td\u003e\n\u003ctd data-start=\"3255\" data-end=\"3264\" data-col-size=\"md\"\u003e4 pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3265\" data-end=\"3369\"\u003e\n\u003ctd data-start=\"3265\" data-end=\"3286\" data-col-size=\"sm\"\u003eProtection Devices\u003c\/td\u003e\n\u003ctd data-start=\"3286\" data-end=\"3369\" data-col-size=\"md\"\u003eFlow detection, liquid level alarm, over-temperature \u0026amp; over-pressure protection\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3370\" data-end=\"3394\"\u003e\n\u003ctd data-start=\"3370\" data-end=\"3380\" data-col-size=\"sm\"\u003eDisplay\u003c\/td\u003e\n\u003ctd data-start=\"3380\" data-end=\"3394\" data-col-size=\"md\"\u003e7-inch LCD\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3395\" data-end=\"3419\"\u003e\n\u003ctd data-start=\"3395\" data-end=\"3409\" data-col-size=\"sm\"\u003eRated Power\u003c\/td\u003e\n\u003ctd data-start=\"3409\" data-end=\"3419\" data-col-size=\"md\"\u003e1.4 kW\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3420\" data-end=\"3490\"\u003e\n\u003ctd data-start=\"3420\" data-end=\"3435\" data-col-size=\"sm\"\u003ePower Supply\u003c\/td\u003e\n\u003ctd data-start=\"3435\" data-end=\"3490\" data-col-size=\"md\"\u003e220V, 50\/60Hz (Standard) \/ 110V, 50\/60Hz (Optional)\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3491\" data-end=\"3537\"\u003e\n\u003ctd data-start=\"3491\" data-end=\"3515\" data-col-size=\"sm\"\u003eExternal Size (W×D×H)\u003c\/td\u003e\n\u003ctd data-start=\"3515\" data-end=\"3537\" data-col-size=\"md\"\u003e490 × 380 × 725 mm\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3538\" data-end=\"3584\"\u003e\n\u003ctd data-start=\"3538\" data-end=\"3561\" data-col-size=\"sm\"\u003ePacking Size (W×D×H)\u003c\/td\u003e\n\u003ctd data-start=\"3561\" data-end=\"3584\" data-col-size=\"md\"\u003e630 × 560 × 1350 mm\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3585\" data-end=\"3607\"\u003e\n\u003ctd data-start=\"3585\" data-end=\"3598\" data-col-size=\"sm\"\u003eNet Weight\u003c\/td\u003e\n\u003ctd data-start=\"3598\" data-end=\"3607\" data-col-size=\"md\"\u003e35 kg\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"3608\" data-end=\"3632\"\u003e\n\u003ctd data-start=\"3608\" data-end=\"3623\" data-col-size=\"sm\"\u003eGross Weight\u003c\/td\u003e\n\u003ctd data-start=\"3623\" data-end=\"3632\" data-col-size=\"md\"\u003e52 kg\u003c\/td\u003e\n\u003ctd data-col-size=\"md\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003eDownloads\u003c\/h4\u003e\n\u003cp\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/85-86_Semi_Automatic_Kjeldahl_Nitrogen_Analyzer_Fully-automatic_Kjeldahl_Nitrogen_Analyzer_3.pdf?v=1771320690\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Biobase","offers":[{"title":"Default Title","offer_id":45172610826431,"sku":"AKN-01","price":72200.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/2587-202305031503549108.jpg?v=1771320699","url":"https:\/\/inspectiontools.co.za\/products\/semi-automatic-kjeldahl-nitrogen-analyzer-protein-nitrogen-testing-system-akn-01","provider":"Inspection Tool Specialists","version":"1.0","type":"link"}