{"product_id":"mpi-reference-test-block","title":"MPI Reference Test Block","description":"\u003ch3 data-start=\"355\" data-end=\"410\"\u003e\u003cstrong data-start=\"362\" data-end=\"410\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"412\" data-end=\"872\"\u003e\u003cstrong data-start=\"412\" data-end=\"497\"\u003eMR® Reference Test Block 1 – For Magnetic Particle Suspension Sensitivity Control\u003c\/strong\u003e\u003cbr data-start=\"497\" data-end=\"500\"\u003eDesigned for reliable verification of magnetic particle testing media, the MR® Reference Test Block 1 ensures the indication sensitivity of both colored and fluorescent magnetic particle suspensions. Manufactured in accordance with \u003cstrong data-start=\"732\" data-end=\"749\"\u003eEN ISO 9934-2\u003c\/strong\u003e, this metal disc features residual magnetization and a series of rough and fine artificial cracks for accurate comparison.\u003c\/p\u003e\n\u003cp data-start=\"874\" data-end=\"1072\"\u003eIt is ideal for routine quality control, field verification, and laboratory inspections, helping ensure that your magnetic particle test medium continues to meet international performance standards.\u003c\/p\u003e\n\u003chr data-start=\"1074\" data-end=\"1077\"\u003e\n\u003cp data-start=\"1079\" data-end=\"1099\"\u003e\u003cstrong data-start=\"1079\" data-end=\"1099\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1101\" data-end=\"1869\"\u003e\n\u003cli data-start=\"1101\" data-end=\"1198\"\u003e\n\u003cp data-start=\"1103\" data-end=\"1198\"\u003e\u003cstrong data-start=\"1103\" data-end=\"1127\"\u003eStandards-Compliant:\u003c\/strong\u003e Fully compliant with \u003cstrong data-start=\"1149\" data-end=\"1166\"\u003eEN ISO 9934-2\u003c\/strong\u003e for Magnetic Particle Testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1199\" data-end=\"1293\"\u003e\n\u003cp data-start=\"1201\" data-end=\"1293\"\u003e\u003cstrong data-start=\"1201\" data-end=\"1228\"\u003eResidual Magnetization:\u003c\/strong\u003e Pre-magnetized for easy use—no external magnetization required\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1294\" data-end=\"1406\"\u003e\n\u003cp data-start=\"1296\" data-end=\"1406\"\u003e\u003cstrong data-start=\"1296\" data-end=\"1325\"\u003ePrecision-Crafted Cracks:\u003c\/strong\u003e Features both rough and fine surface cracks for multi-level sensitivity checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1407\" data-end=\"1479\"\u003e\n\u003cp data-start=\"1409\" data-end=\"1479\"\u003e\u003cstrong data-start=\"1409\" data-end=\"1434\"\u003eUnique Serial Number:\u003c\/strong\u003e Laser-stamped on the side for traceability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1480\" data-end=\"1585\"\u003e\n\u003cp data-start=\"1482\" data-end=\"1585\"\u003e\u003cstrong data-start=\"1482\" data-end=\"1506\"\u003eCertified Reference:\u003c\/strong\u003e Supplied with a certificate and photographic reference for visual comparison\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1586\" data-end=\"1679\"\u003e\n\u003cp data-start=\"1588\" data-end=\"1679\"\u003e\u003cstrong data-start=\"1588\" data-end=\"1601\"\u003eDual-Use:\u003c\/strong\u003e Suitable for both \u003cstrong data-start=\"1620\" data-end=\"1631\"\u003ecolored\u003c\/strong\u003e and \u003cstrong data-start=\"1636\" data-end=\"1651\"\u003efluorescent\u003c\/strong\u003e magnetic particle testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1680\" data-end=\"1775\"\u003e\n\u003cp data-start=\"1682\" data-end=\"1775\"\u003e\u003cstrong data-start=\"1682\" data-end=\"1703\"\u003eSurface Cleaning:\u003c\/strong\u003e Easy to maintain—recommended ultrasonic cleaning or gentle cloth wipe\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1776\" data-end=\"1869\"\u003e\n\u003cp data-start=\"1778\" data-end=\"1869\"\u003e\u003cstrong data-start=\"1778\" data-end=\"1809\"\u003eDurable Metal Construction:\u003c\/strong\u003e Built to withstand repeated inspections under proper care\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1871\" data-end=\"1874\"\u003e\n\u003cp data-start=\"1876\" data-end=\"1902\"\u003e\u003cstrong data-start=\"1876\" data-end=\"1902\"\u003eUsage Instructions:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-start=\"1904\" data-end=\"2413\"\u003e\n\u003cli data-start=\"1904\" data-end=\"2193\"\u003e\n\u003cp data-start=\"1907\" data-end=\"1951\"\u003e\u003cstrong data-start=\"1907\" data-end=\"1949\"\u003eFor Colored Magnetic Particle Testing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1955\" data-end=\"2193\"\u003e\n\u003cli data-start=\"1955\" data-end=\"2014\"\u003e\n\u003cp data-start=\"1957\" data-end=\"2014\"\u003eApply white contrast paint to the block and let it dry.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2018\" data-end=\"2107\"\u003e\n\u003cp data-start=\"2020\" data-end=\"2107\"\u003eApply colored magnetic particle suspension (by spray or dip), let the excess run off.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2111\" data-end=\"2193\"\u003e\n\u003cp data-start=\"2113\" data-end=\"2193\"\u003eInspect under daylight as per \u003cstrong data-start=\"2143\" data-end=\"2158\"\u003eEN ISO 3059\u003c\/strong\u003e; compare with the reference photo.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2195\" data-end=\"2413\"\u003e\n\u003cp data-start=\"2198\" data-end=\"2246\"\u003e\u003cstrong data-start=\"2198\" data-end=\"2244\"\u003eFor Fluorescent Magnetic Particle Testing:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2250\" data-end=\"2413\"\u003e\n\u003cli data-start=\"2250\" data-end=\"2325\"\u003e\n\u003cp data-start=\"2252\" data-end=\"2325\"\u003eApply fluorescent suspension (by spray or dip), let the excess run off.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2329\" data-end=\"2413\"\u003e\n\u003cp data-start=\"2331\" data-end=\"2413\"\u003eInspect under UV light according to \u003cstrong data-start=\"2367\" data-end=\"2382\"\u003eEN ISO 3059\u003c\/strong\u003e; compare with reference image.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp data-start=\"2415\" data-end=\"2493\"\u003eIf \u003cstrong data-start=\"2420\" data-end=\"2434\"\u003eall cracks\u003c\/strong\u003e are clearly indicated, the suspension is approved for use.\u003c\/p\u003e\n\u003chr data-start=\"2495\" data-end=\"2498\"\u003e\n\u003cp data-start=\"2500\" data-end=\"2525\"\u003e\u003cstrong data-start=\"2500\" data-end=\"2525\"\u003eScope of Delivery:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2527\" data-end=\"2648\"\u003e\n\u003cli data-start=\"2527\" data-end=\"2553\"\u003e\n\u003cp data-start=\"2529\" data-end=\"2553\"\u003eReference Test Block 1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2554\" data-end=\"2601\"\u003e\n\u003cp data-start=\"2556\" data-end=\"2601\"\u003eInspection Certificate with Reference Photo\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2602\" data-end=\"2648\"\u003e\n\u003cp data-start=\"2604\" data-end=\"2648\"\u003eIndividually Serialized Block (Art. No. 959)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2650\" data-end=\"2653\"\u003e\n\u003cp data-start=\"2655\" data-end=\"2676\"\u003e\u003cstrong data-start=\"2655\" data-end=\"2676\"\u003eSpecial Notes:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2678\" data-end=\"2942\"\u003e\n\u003cli data-start=\"2678\" data-end=\"2767\"\u003e\n\u003cp data-start=\"2680\" data-end=\"2767\"\u003eAvoid contamination with oil, grease, or exposure to strong external magnetic fields.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2768\" data-end=\"2850\"\u003e\n\u003cp data-start=\"2770\" data-end=\"2850\"\u003eSeparate reference blocks are recommended for colored and fluorescent methods.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2851\" data-end=\"2942\"\u003e\n\u003cp data-start=\"2853\" data-end=\"2942\"\u003eDo not demagnetize. Clean gently using a slightly damp cloth or ultrasonic cleaning bath.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\n\u003cp\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/MTU-Reference_Test_Block-1_1.pdf?v=1755205693\"\u003eLink\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/MR_975_PDS_1.pdf?v=1755203911\"\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Mr Chemie","offers":[{"title":"Default Title","offer_id":44464340402367,"sku":"Magnetic Particle Testing – Reference Test Block 1 | Sensitivity Check (EN ISO 9934-2)","price":8900.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/mtu-blok.png?v=1755205800","url":"https:\/\/inspectiontools.co.za\/products\/mpi-reference-test-block","provider":"Inspection Tool Specialists","version":"1.0","type":"link"}