{"product_id":"high-temperature-split-type-ultrasonic-flow-meter-tmi-fm-111","title":"High-Temperature Split-Type Ultrasonic Flow Meter – TMI-FM-111","description":"\u003ch1\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/h1\u003e\u003cp\u003eThe TOMLIN INSTRUMENTS TMI-FM-111 is a high-temperature split-type clamp-on ultrasonic flow meter for hot liquids from 0 to 120 °C in pipes from DN125 to DN250. Dedicated high-temperature transducers and cables connect to a DIN-rail transmitter.\u003c\/p\u003e\u003cp\u003eA colour IPS display shows flow rate, velocity and totals, and 4 – 20 mA and RS485 Modbus outputs connect to PLC and building systems. Accuracy is ±2.0% from 0.5 to 5 m\/s on clean liquids from 0 to 120 °C in metal pipes.\u003c\/p\u003e\u003chr\u003e\u003ch1\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/h1\u003e\u003cul\u003e\n\u003cli\u003eClamp-on, non-invasive: no pipe cutting or shutdown\u003c\/li\u003e\n\u003cli\u003eMagnetic latching bracket for one-person fitting\u003c\/li\u003e\n\u003cli\u003eDIN-rail transmitter, separate transducer\u003c\/li\u003e\n\u003cli\u003eGel-free coupling pads\u003c\/li\u003e\n\u003cli\u003e4 – 20 mA and RS485 Modbus outputs\u003c\/li\u003e\n\u003cli\u003eMenu-driven 4-key setup\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch1\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h1\u003e\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width: 100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTMI-FM-111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSplit type with high-temperature transducer and cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePipe sizes\u003c\/td\u003e\n\u003ctd\u003eDN125 – DN250 (pipe OD 115 – 277 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid temperature\u003c\/td\u003e\n\u003ctd\u003e0 – 120 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±2.0% (0.5 – 5.0 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow velocity range\u003c\/td\u003e\n\u003ctd\u003e0.1 – 5.0 m\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e±2.0% (0.5 – 5.0 m\/s)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e0.8%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse time\u003c\/td\u003e\n\u003ctd\u003e500 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e1.54-inch 240 × 240 IPS colour, four-way rotation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUnits\u003c\/td\u003e\n\u003ctd\u003em³\/h, L\/min, L\/s, L\/h, mL\/min, GPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotaliser\u003c\/td\u003e\n\u003ctd\u003e7-digit; net, single, day \/ month \/ year totals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData storage\u003c\/td\u003e\n\u003ctd\u003e10 years, 64 months, 64 days\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003e4 touch keys\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e24 V DC, 3 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalogue output\u003c\/td\u003e\n\u003ctd\u003e4 – 20 mA (max. load 600 Ω)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eRS485, Modbus RTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal output\u003c\/td\u003e\n\u003ctd\u003eFlow alarm, totaliser pulse (optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing\u003c\/td\u003e\n\u003ctd\u003eAluminium alloy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbient humidity\u003c\/td\u003e\n\u003ctd\u003e0 – 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch1\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/h1\u003e\u003ctable border=\"0\" cellpadding=\"1\" cellspacing=\"1\" style=\"width: 100%;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003eTMI-FM-111-01\u003c\/td\u003e\n\u003ctd\u003eDN125 (5\"), pipe OD 115 – 142 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003eTMI-FM-111-02\u003c\/td\u003e\n\u003ctd\u003eDN150 (6\"), pipe OD 142 – 169 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003eTMI-FM-111-03\u003c\/td\u003e\n\u003ctd\u003eDN175 (7\"), pipe OD 169 – 196 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003eTMI-FM-111-04\u003c\/td\u003e\n\u003ctd\u003eDN200 (8\"), pipe OD 196 – 223 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003eTMI-FM-111-05\u003c\/td\u003e\n\u003ctd\u003eDN225 (9\"), pipe OD 223 – 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 35%;\"\u003eTMI-FM-111-06\u003c\/td\u003e\n\u003ctd\u003eDN250 (10\"), pipe OD 250 – 277 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003ch1\u003e\u003cstrong\u003eIndustries Used In\u003c\/strong\u003e\u003c\/h1\u003e\u003cul\u003e\n\u003cli\u003eHot-water and heating circuits\u003c\/li\u003e\n\u003cli\u003eBoiler feed and condensate return\u003c\/li\u003e\n\u003cli\u003eProcess liquids up to 120 °C\u003c\/li\u003e\n\u003cli\u003eBuilding services\u003c\/li\u003e\n\u003cli\u003eRetrofit metering without cutting the pipe\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch6\u003eDownloads\u003c\/h6\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/TOMLIN-Datasheet-TMI-FM-111.pdf?v=1795409579\" rel=\"noopener\" target=\"_blank\"\u003eDatasheet – TMI-FM-111\u003c\/a\u003e\u003c\/p\u003e","brand":"TOMLIN Instruments","offers":[{"title":"DN125 (5\") – pipe OD 115–142 mm","offer_id":68084790329535,"sku":"TMI-FM-111-01","price":45690.0,"currency_code":"ZAR","in_stock":true},{"title":"DN150 (6\") – pipe OD 142–169 mm","offer_id":68084790362303,"sku":"TMI-FM-111-02","price":52940.0,"currency_code":"ZAR","in_stock":true},{"title":"DN175 (7\") – pipe OD 169–196 mm","offer_id":68084790395071,"sku":"TMI-FM-111-03","price":54770.0,"currency_code":"ZAR","in_stock":true},{"title":"DN200 (8\") – pipe OD 196–223 mm","offer_id":68084790427839,"sku":"TMI-FM-111-04","price":60740.0,"currency_code":"ZAR","in_stock":true},{"title":"DN225 (9\") – pipe OD 223–250 mm","offer_id":68084790460607,"sku":"TMI-FM-111-05","price":66330.0,"currency_code":"ZAR","in_stock":true},{"title":"DN250 (10\") – pipe OD 250–277 mm","offer_id":68084790493375,"sku":"TMI-FM-111-06","price":74710.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/tomlin-tmi-fm-111-high-temperature-split-type-ultrasonic-flow-meter.jpg?v=1795409827","url":"https:\/\/inspectiontools.co.za\/products\/high-temperature-split-type-ultrasonic-flow-meter-tmi-fm-111","provider":"Inspection Tool Specialists","version":"1.0","type":"link"}