{"product_id":"geiger-counter-pce-ram-100-ica-incl-iso-calibration-certificate","title":"Geiger Counter PCE-RAM 100-ICA (incl. ISO-Calibration Certificate)","description":"\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-center\"\u003e\u003cstrong\u003eGeiger Counter for α, β, γ radiation \/ internal memory for 10 million measuring points \/ units µSv and mrem \/ pulse counting in cps and cpm \/ MAX, MIN, AVG \/ 13 menu languages\u003c\/strong\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"row\"\u003e\n\u003cdiv class=\"col-md-12 text-justify\"\u003e\n\u003cp\u003eThe Geiger Counter offers comprehensive measurement functions for α, β and γ radiation and is the test instrument of choice for professional radiation measurements. With the ability to precisely record the accumulated radiation dose and count the radiation in both cps (counts per second) and cpm (counts per minute), the Geiger Counter provides accurate and reliable measurement data at all times. The integrated data logger with 32 GB memory saves the measured values and allows them to be analysed in detail. The measurement history is shown graphically on the TFT colour display. Individual alarm limits can also be set in the Geiger Counter: a warning message appears if a certain radiation value or a defined radiation dose is exceeded.\u003cbr\u003e\u003cbr\u003eAnother feature of the Geiger Counter is the acoustic radiation pulse output. Each detected radiation pulse is made audible by a sound, which provides immediate feedback on the radiation activity in the environment. This function can also be deactivated. The integrated data logger can record up to 10 million measuring points at the touch of a key or after entering a start time.\u003cbr\u003e\u003cbr\u003eThis Geiger Counter combines precision, ease of use and innovative technology - an indispensable tool for the safe handling of radioactive materials. Radiation protection officers and safety specialists use the Geiger Counter when they are exposed to radioactive environments but it can also be used quickly in scientific fields such as nuclear research, medical physics or for simple environmental monitoring.\u003c\/p\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e- α, β, γ radiation\u003c\/div\u003e\n\u003cdiv\u003e- accumulated radiation dose\u003c\/div\u003e\n\u003cdiv\u003e- pulse counting in cps and cpm\u003c\/div\u003e\n\u003cdiv\u003e- data logger with 32 GB memory\u003c\/div\u003e\n\u003cdiv\u003e- adjustable alarm\u003c\/div\u003e\n\u003cdiv\u003e- graphical measurement history\u003c\/div\u003e\n\u003cdiv\u003e- audible radiation pulse\u003c\/div\u003e\n\u003cdiv\u003e- incl. ISO-Calibration Certificate\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable border=\"0\" bgcolor=\"#fff\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eRadiation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range up to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 1500 µSv\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0,001 µSv\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;10 % of Rd (\u0026lt;1000 µSv\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eRadiation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range up to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 150 mrem\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0,001 mrem\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;10 % of Rd (\u0026lt;100 mrem\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eRadiation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range up to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 9,9 Sv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0,1 Sv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;10 % of Rd (\u0026lt;100 µSv)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eRadiation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range up to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 167000 cps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 cps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;10 % of Rd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eRadiation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasurement range up to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e0 ... 9999999 cpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eResolution  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 cpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAccuracy  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u0026lt;10 % of Rd\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003eGeneral technical data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMeasuring functions  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eMIN, MAX, Average value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay type  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eTFT colour display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDisplay size  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2,8 Inch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage medium  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eInternal memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage capacity  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e32 GB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMemory capacity (additional information)  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e10 million measuring points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage interval from  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage interval to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e12 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eInterface  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSensor  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eGeiger-Müller counter tube (metallic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSensor additional information  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eStainless steel housing with hallogen filling\u003cbr\u003e- Measuring length = 38.1 mm\u003cbr\u003e- Measuring diameter = 9.1 mm\u003cbr\u003e- Window = 1.5 ... 2.5 mg\/m²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating time  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e12 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating time additional information  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003edepending on display brightness and data logger settings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAutomatic power-off from...to  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 ... 15 min.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAutomatic power-off can be deactivated  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAlarm  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eoptical, Acoustic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eAlarm modes  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eRadiation, radiation dose, number of pulses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSensitivity  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eα-rays from 4 MeV\u003cbr\u003eβ-rays from 0.2 MeV\u003cbr\u003eγ-rays from 30 keV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eSelector diaphragm  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eAlpha + Beta + Gamma (without filter)\u003cbr\u003eBeta + gamma (aluminium foil (approx. 0.1 mm) shielding alpha rays)\u003cbr\u003eGamma (aluminium shield (approx. 3 mm) shields alpha rays, beta radiation from approx. 2 MeV, attenuates gamma approx. \u0026lt;7 %)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eMenu language  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eGerman, English (GB), English, French, Spanish, Italian, Danish, Portuguese, Turkish, Polish, Russian, Chinese, Dutch, Japanese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eProtection class (device)  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003eIP52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003ePower supply  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e5 V DC, 500 mA (USB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e(Rechargeable) battery  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e1 x 3,7 V internal , Lithium polymer battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eCapacity  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e2500 mAh\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eOperating conditions  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-20 ... 65 °C , 10 ... 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eStorage conditions  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e-20 ... 65 °C , 10 ... 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"attribute\"\u003e\n\u003ctd valign=\"top\"\u003eDimensions ( L x W x H )  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e208 x 85 x 37 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eWeight  \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e280 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv\u003e1 x PCE-RAM 100-ICA Geiger Counter\u003c\/div\u003e\n\u003cdiv\u003e1 x USB-C cable\u003c\/div\u003e\n\u003cdiv\u003e1 x quick start guide\u003c\/div\u003e\n\u003cdiv\u003e1 x service bag\u003c\/div\u003e\n\u003cdiv\u003e1 x ISO-Calibration Certificate\u003c\/div\u003e\n\u003cdiv\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/us\/api\/getartfile?_fnr=2976468\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cimg class=\"lazy\" width=\"82\" height=\"67\" src=\"https:\/\/www.pce-instruments.com\/us\/g\/mime\/custom_datasheet.US.gif\" data-original=\"\/us\/g\/mime\/custom_datasheet.US.gif\" alt=\"pce-instruments-d688320e9a92fab09.pdf\"\u003e\u003cspan class=\"mimetitle mimetitlet_custom_datasheet mimetitlel_US\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/us\/api\/getartfile?_fnr=2976470\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cimg class=\"lazy\" width=\"82\" height=\"67\" src=\"https:\/\/www.pce-instruments.com\/us\/g\/mime\/custom_certificate_ce.US.gif\" data-original=\"\/us\/g\/mime\/custom_certificate_ce.US.gif\" alt=\"pce-instruments-e66f117182fb1b1fb.pdf\"\u003e\u003cspan class=\"mimetitle mimetitlet_custom_certificate_ce mimetitlel_US\"\u003eCE Certificate\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Inspection Tool Specialists","offers":[{"title":"Default Title","offer_id":45498597769407,"sku":null,"price":16750.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/123.png?v=1776237464","url":"https:\/\/inspectiontools.co.za\/products\/geiger-counter-pce-ram-100-ica-incl-iso-calibration-certificate","provider":"Inspection Tool Specialists","version":"1.0","type":"link"}