{"product_id":"dye-penetrant-water-washable-penetrant-mr311-r","title":"Dye Penetrant Water Washable Penetrant MR311-R","description":"\u003ch3 data-start=\"312\" data-end=\"367\"\u003e\u003cstrong data-start=\"319\" data-end=\"367\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"369\" data-end=\"729\"\u003e\u003cstrong data-start=\"369\" data-end=\"428\"\u003eMR® 311-R Penetrant Red – Visible Dye Penetrant for NDT\u003c\/strong\u003e\u003cbr data-start=\"428\" data-end=\"431\"\u003eThe MR® 311-R is a high-quality, visible red dye penetrant designed for \u003cstrong data-start=\"503\" data-end=\"514\"\u003eType II\u003c\/strong\u003e inspections with \u003cstrong data-start=\"532\" data-end=\"555\"\u003eSensitivity Level 2\u003c\/strong\u003e in accordance with \u003cstrong data-start=\"575\" data-end=\"590\"\u003eEN ISO 3452\u003c\/strong\u003e. Formulated for both water and solvent removal methods, it provides sharp, clear red indications of surface-breaking cracks and defects.\u003c\/p\u003e\n\u003cp data-start=\"731\" data-end=\"958\"\u003eSuitable for all metals with excellent wetting properties, this penetrant is widely used in maintenance, manufacturing, and field inspection work. Its carrier medium glycol base ensures consistent coverage and reliable results.\u003c\/p\u003e\n\u003chr data-start=\"960\" data-end=\"963\"\u003e\n\u003cp data-start=\"965\" data-end=\"985\"\u003e\u003cstrong data-start=\"965\" data-end=\"985\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"987\" data-end=\"1490\"\u003e\n\u003cli data-start=\"987\" data-end=\"1074\"\u003e\n\u003cp data-start=\"989\" data-end=\"1074\"\u003e\u003cstrong data-start=\"989\" data-end=\"1022\"\u003eType II Visible Dye Penetrant\u003c\/strong\u003e – Bright red crack indications for easy detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1075\" data-end=\"1157\"\u003e\n\u003cp data-start=\"1077\" data-end=\"1157\"\u003e\u003cstrong data-start=\"1077\" data-end=\"1101\"\u003eDual Removal Methods\u003c\/strong\u003e – Water-washable or solvent-removable for flexibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1158\" data-end=\"1229\"\u003e\n\u003cp data-start=\"1160\" data-end=\"1229\"\u003e\u003cstrong data-start=\"1160\" data-end=\"1183\"\u003eSensitivity Level 2\u003c\/strong\u003e – Balanced for a wide range of applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1230\" data-end=\"1312\"\u003e\n\u003cp data-start=\"1232\" data-end=\"1312\"\u003e\u003cstrong data-start=\"1232\" data-end=\"1264\"\u003eExcellent Wetting Properties\u003c\/strong\u003e – Ensures full surface coverage on all metals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1313\" data-end=\"1423\"\u003e\n\u003cp data-start=\"1315\" data-end=\"1423\"\u003e\u003cstrong data-start=\"1315\" data-end=\"1341\"\u003eMaterial Compatibility\u003c\/strong\u003e – For metals; suitability for plastics and ceramics must be verified before use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1424\" data-end=\"1490\"\u003e\n\u003cp data-start=\"1426\" data-end=\"1490\"\u003e\u003cstrong data-start=\"1426\" data-end=\"1457\"\u003eGlycol-Based Carrier Medium\u003c\/strong\u003e – Stable, consistent performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1492\" data-end=\"1495\"\u003e\n\u003cp data-start=\"1497\" data-end=\"1531\"\u003e\u003cstrong data-start=\"1497\" data-end=\"1531\"\u003eApprovals \u0026amp; Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1533\" data-end=\"1622\"\u003e\n\u003cli data-start=\"1533\" data-end=\"1550\"\u003e\n\u003cp data-start=\"1535\" data-end=\"1550\"\u003eEN ISO 3452-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1551\" data-end=\"1564\"\u003e\n\u003cp data-start=\"1553\" data-end=\"1564\"\u003eASTM E165\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1565\" data-end=\"1573\"\u003e\n\u003cp data-start=\"1567\" data-end=\"1573\"\u003ePMUC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1574\" data-end=\"1583\"\u003e\n\u003cp data-start=\"1576\" data-end=\"1583\"\u003eRCC-M\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1584\" data-end=\"1607\"\u003e\n\u003cp data-start=\"1586\" data-end=\"1607\"\u003eASME Code V, Art. 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1608\" data-end=\"1622\"\u003e\n\u003cp data-start=\"1610\" data-end=\"1622\"\u003eVDA236-150\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1624\" data-end=\"1627\"\u003e\n\u003cp data-start=\"1629\" data-end=\"1667\"\u003e\u003cstrong data-start=\"1629\" data-end=\"1667\"\u003eShelf Life \u0026amp; Temperature Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1669\" data-end=\"1854\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1669\" data-end=\"1690\"\u003e\n\u003ctr data-start=\"1669\" data-end=\"1690\"\u003e\n\u003cth data-start=\"1669\" data-end=\"1681\" data-col-size=\"sm\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1681\" data-end=\"1690\" data-col-size=\"sm\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1713\" data-end=\"1854\"\u003e\n\u003ctr data-start=\"1713\" data-end=\"1758\"\u003e\n\u003ctd data-start=\"1713\" data-end=\"1730\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1715\" data-end=\"1729\"\u003eShelf Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1730\" data-end=\"1758\" data-col-size=\"sm\"\u003e3 years (aerosol \u0026amp; bulk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1759\" data-end=\"1804\"\u003e\n\u003ctd data-start=\"1759\" data-end=\"1785\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1761\" data-end=\"1784\"\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1785\" data-end=\"1804\" data-col-size=\"sm\"\u003e+5 °C to +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1805\" data-end=\"1854\"\u003e\n\u003ctd data-start=\"1805\" data-end=\"1835\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1807\" data-end=\"1834\"\u003eApplication Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1835\" data-end=\"1854\" data-col-size=\"sm\"\u003e+5 °C to +50 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1856\" data-end=\"1859\"\u003e\n\u003cp data-start=\"1861\" data-end=\"1888\"\u003e\u003cstrong data-start=\"1861\" data-end=\"1888\"\u003eAvailable Packaging:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1890\" data-end=\"1952\"\u003e\n\u003cli data-start=\"1890\" data-end=\"1908\"\u003e\n\u003cp data-start=\"1892\" data-end=\"1908\"\u003e500 mL aerosol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1909\" data-end=\"1920\"\u003e\n\u003cp data-start=\"1911\" data-end=\"1920\"\u003e1 L can\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1921\" data-end=\"1937\"\u003e\n\u003cp data-start=\"1923\" data-end=\"1937\"\u003e5 L canister\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1938\" data-end=\"1952\"\u003e\n\u003cp data-start=\"1940\" data-end=\"1952\"\u003e200 L drum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1954\" data-end=\"1957\"\u003e\n\u003cp data-start=\"1959\" data-end=\"1987\"\u003e\u003cstrong data-start=\"1959\" data-end=\"1987\"\u003eRecommended Pairings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1989\" data-end=\"2211\"\u003e\n\u003cli data-start=\"1989\" data-end=\"2053\"\u003e\n\u003cp data-start=\"1991\" data-end=\"2053\"\u003e\u003cstrong data-start=\"1991\" data-end=\"2008\"\u003ePre-cleaners:\u003c\/strong\u003e MR® 79, MR® 85, MR® 88, MR® 3001, MR® 3002\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2054\" data-end=\"2101\"\u003e\n\u003cp data-start=\"2056\" data-end=\"2101\"\u003e\u003cstrong data-start=\"2056\" data-end=\"2069\"\u003eRemovers:\u003c\/strong\u003e MR® 79, MR® 85, MR® 88, Water\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2102\" data-end=\"2147\"\u003e\n\u003cp data-start=\"2104\" data-end=\"2147\"\u003e\u003cstrong data-start=\"2104\" data-end=\"2119\"\u003eDevelopers:\u003c\/strong\u003e MR® 70, MR® 703 W (+5 °C)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2148\" data-end=\"2211\"\u003e\n\u003cp data-start=\"2150\" data-end=\"2211\"\u003e\u003cstrong data-start=\"2150\" data-end=\"2166\"\u003eTest Blocks:\u003c\/strong\u003e Reference Testblock 1 \u0026amp; 2, ASTM Test Block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mr Chemie","offers":[{"title":"Box (10x 400ml)","offer_id":44464458825919,"sku":"MR311-R","price":2415.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/mr-311r.png?v=1755208135","url":"https:\/\/inspectiontools.co.za\/products\/dye-penetrant-water-washable-penetrant-mr311-r","provider":"Inspection Tool Specialists","version":"1.0","type":"link"}