{"product_id":"dye-penetrant-fluorescent-white-developer-mr70","title":"Dye Penetrant Fluorescent White Developer MR70","description":"\u003ch3 data-start=\"313\" data-end=\"368\"\u003e\u003cstrong data-start=\"320\" data-end=\"368\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"370\" data-end=\"727\"\u003e\u003cstrong data-start=\"370\" data-end=\"430\"\u003eMR® 70 AMS Developer White – Solvent-Based NDT Developer\u003c\/strong\u003e\u003cbr data-start=\"430\" data-end=\"433\"\u003eThe MR® 70 AMS Developer White is a solvent-based developer formulated for penetrant testing in compliance with \u003cstrong data-start=\"545\" data-end=\"560\"\u003eEN ISO 3452\u003c\/strong\u003e. It creates a bright white contrast background to enhance defect visibility during inspection, dries quickly for efficient testing, and is easy to remove after use.\u003c\/p\u003e\n\u003cp data-start=\"729\" data-end=\"864\"\u003eSuitable for a wide range of penetrant methods, this developer is an essential step in achieving clear and accurate inspection results.\u003c\/p\u003e\n\u003chr data-start=\"866\" data-end=\"869\"\u003e\n\u003cp data-start=\"871\" data-end=\"891\"\u003e\u003cstrong data-start=\"871\" data-end=\"891\"\u003eKey Features:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"893\" data-end=\"1268\"\u003e\n\u003cli data-start=\"893\" data-end=\"963\"\u003e\n\u003cp data-start=\"895\" data-end=\"963\"\u003e\u003cstrong data-start=\"895\" data-end=\"929\"\u003eStandards-Compliant Developer:\u003c\/strong\u003e EN ISO 3452-2, -5, -6 certified\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"964\" data-end=\"1021\"\u003e\n\u003cp data-start=\"966\" data-end=\"1021\"\u003e\u003cstrong data-start=\"966\" data-end=\"991\"\u003eQuick-Drying Formula:\u003c\/strong\u003e Speeds up inspection cycles\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1022\" data-end=\"1073\"\u003e\n\u003cp data-start=\"1024\" data-end=\"1073\"\u003e\u003cstrong data-start=\"1024\" data-end=\"1043\"\u003eEasy to Remove:\u003c\/strong\u003e Leaves no permanent residue\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1074\" data-end=\"1142\"\u003e\n\u003cp data-start=\"1076\" data-end=\"1142\"\u003e\u003cstrong data-start=\"1076\" data-end=\"1097\"\u003eUniform Coverage:\u003c\/strong\u003e Ensures clear and sharp defect indications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1143\" data-end=\"1208\"\u003e\n\u003cp data-start=\"1145\" data-end=\"1208\"\u003e\u003cstrong data-start=\"1145\" data-end=\"1171\"\u003eOptimized Application:\u003c\/strong\u003e Spray from ~20 cm for best results\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1209\" data-end=\"1268\"\u003e\n\u003cp data-start=\"1211\" data-end=\"1268\"\u003e\u003cstrong data-start=\"1211\" data-end=\"1238\"\u003eSolvent Carrier Medium:\u003c\/strong\u003e Provides smooth, even coating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1270\" data-end=\"1273\"\u003e\n\u003cp data-start=\"1275\" data-end=\"1309\"\u003e\u003cstrong data-start=\"1275\" data-end=\"1309\"\u003eApprovals \u0026amp; Specifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1311\" data-end=\"1508\"\u003e\n\u003cli data-start=\"1311\" data-end=\"1358\"\u003e\n\u003cp data-start=\"1313\" data-end=\"1358\"\u003eEN ISO 3452-2, EN ISO 3452-5, EN ISO 3452-6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1359\" data-end=\"1384\"\u003e\n\u003cp data-start=\"1361\" data-end=\"1384\"\u003eASTM E165, ASTM E1417\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1385\" data-end=\"1414\"\u003e\n\u003cp data-start=\"1387\" data-end=\"1414\"\u003eAMS 2644 (QPL SAE listed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1415\" data-end=\"1438\"\u003e\n\u003cp data-start=\"1417\" data-end=\"1438\"\u003eASME Code V, Art. 6\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1439\" data-end=\"1454\"\u003e\n\u003cp data-start=\"1441\" data-end=\"1454\"\u003eRCC-M, PMUC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1455\" data-end=\"1478\"\u003e\n\u003cp data-start=\"1457\" data-end=\"1478\"\u003eTLV 9017 01:2011-01\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1479\" data-end=\"1493\"\u003e\n\u003cp data-start=\"1481\" data-end=\"1493\"\u003eJIS 2343-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1494\" data-end=\"1508\"\u003e\n\u003cp data-start=\"1496\" data-end=\"1508\"\u003eVDA236-150\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1510\" data-end=\"1513\"\u003e\n\u003cp data-start=\"1515\" data-end=\"1553\"\u003e\u003cstrong data-start=\"1515\" data-end=\"1553\"\u003eShelf Life \u0026amp; Temperature Range:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"_tableWrapper_1rjym_13 group flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1555\" data-end=\"1800\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1555\" data-end=\"1576\"\u003e\n\u003ctr data-start=\"1555\" data-end=\"1576\"\u003e\n\u003cth data-start=\"1555\" data-end=\"1567\" data-col-size=\"sm\"\u003eParameter\u003c\/th\u003e\n\u003cth data-start=\"1567\" data-end=\"1576\" data-col-size=\"md\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1599\" data-end=\"1800\"\u003e\n\u003ctr data-start=\"1599\" data-end=\"1644\"\u003e\n\u003ctd data-start=\"1599\" data-end=\"1616\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1601\" data-end=\"1615\"\u003eShelf Life\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1616\" data-end=\"1644\" data-col-size=\"md\"\u003e3 years (aerosol \u0026amp; bulk)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1645\" data-end=\"1690\"\u003e\n\u003ctd data-start=\"1645\" data-end=\"1671\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1647\" data-end=\"1670\"\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1671\" data-end=\"1690\" data-col-size=\"md\"\u003e+5 °C to +45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1691\" data-end=\"1800\"\u003e\n\u003ctd data-start=\"1691\" data-end=\"1721\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1693\" data-end=\"1720\"\u003eApplication Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-start=\"1721\" data-end=\"1800\" data-col-size=\"md\"\u003e-10 °C to +50 °C or -30 °C to +50 °C (with MR® 312, MR® 79, MR® 85, MR® 88)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1802\" data-end=\"1805\"\u003e\n\u003cp data-start=\"1807\" data-end=\"1834\"\u003e\u003cstrong data-start=\"1807\" data-end=\"1834\"\u003eAvailable Packaging:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1836\" data-end=\"1900\"\u003e\n\u003cli data-start=\"1836\" data-end=\"1854\"\u003e\n\u003cp data-start=\"1838\" data-end=\"1854\"\u003e500 mL aerosol\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1855\" data-end=\"1869\"\u003e\n\u003cp data-start=\"1857\" data-end=\"1869\"\u003e1 L bottle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1870\" data-end=\"1886\"\u003e\n\u003cp data-start=\"1872\" data-end=\"1886\"\u003e5 L canister\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1887\" data-end=\"1900\"\u003e\n\u003cp data-start=\"1889\" data-end=\"1900\"\u003e30 L drum\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1902\" data-end=\"1905\"\u003e\n\u003cp data-start=\"1907\" data-end=\"1935\"\u003e\u003cstrong data-start=\"1907\" data-end=\"1935\"\u003eRecommended Pairings:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1937\" data-end=\"2207\"\u003e\n\u003cli data-start=\"1937\" data-end=\"2009\"\u003e\n\u003cp data-start=\"1939\" data-end=\"2009\"\u003e\u003cstrong data-start=\"1939\" data-end=\"1956\"\u003ePre-cleaners:\u003c\/strong\u003e MR® 71, MR® 79, MR® 85, MR® 88, MR® 3001, MR® 3002\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2010\" data-end=\"2094\"\u003e\n\u003cp data-start=\"2012\" data-end=\"2094\"\u003e\u003cstrong data-start=\"2012\" data-end=\"2027\"\u003ePenetrants:\u003c\/strong\u003e Suitable for all Type I, II \u0026amp; III penetrants (except System Hot)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2095\" data-end=\"2142\"\u003e\n\u003cp data-start=\"2097\" data-end=\"2142\"\u003e\u003cstrong data-start=\"2097\" data-end=\"2110\"\u003eRemovers:\u003c\/strong\u003e MR® 79, MR® 85, MR® 88, Water\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2143\" data-end=\"2207\"\u003e\n\u003cp data-start=\"2145\" data-end=\"2207\"\u003e\u003cstrong data-start=\"2145\" data-end=\"2161\"\u003eTest Blocks:\u003c\/strong\u003e Reference Test Block 1 \u0026amp; 2, ASTM Test Block\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Mr Chemie","offers":[{"title":"Box (10x 400ml)","offer_id":44464638787775,"sku":"MR70","price":1190.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/mr-70_1.png?v=1755210056","url":"https:\/\/inspectiontools.co.za\/products\/dye-penetrant-fluorescent-white-developer-mr70","provider":"Inspection Tool Specialists","version":"1.0","type":"link"}