{"product_id":"class-2-sound-calibrator-awa6022a","title":"Class 2 Sound Level Calibrator AWA6022A","description":"\u003cp class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong\u003eAWA6022A\u003c\/strong\u003e is a compact \u003cstrong\u003eClass 2 sound calibrator\u003c\/strong\u003e designed for field calibration and verification of sound level meters, noise dosimeters, measurement microphones and other acoustic measuring instruments.\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eIt generates selectable \u003cstrong\u003e94 dB and 114 dB sound pressure levels at 1 kHz\u003c\/strong\u003e, providing a quick and reliable method of checking instrument sensitivity before and after noise measurements.\u003c\/p\u003e\n\u003cp\u003eWith automatic atmospheric-pressure compensation, simple push-button operation and support for common measurement microphone sizes, the AWA6022A is an economical calibration solution for workplace noise, occupational hygiene, environmental surveys and general acoustic measurement.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIEC 60942:2017 Class 2\u003c\/strong\u003e sound calibrator\u003c\/li\u003e\n\u003cli\u003eGB\/T 15173-2026 compliant\u003c\/li\u003e\n\u003cli\u003eSelectable \u003cstrong\u003e94 dB and 114 dB\u003c\/strong\u003e output\u003c\/li\u003e\n\u003cli\u003e1,000 Hz calibration frequency\u003c\/li\u003e\n\u003cli\u003eSound pressure level accuracy: \u003cstrong\u003e±0.4 dB\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eFrequency accuracy: ±0.7%\u003c\/li\u003e\n\u003cli\u003eAutomatic atmospheric-pressure compensation\u003c\/li\u003e\n\u003cli\u003eStabilisation time of less than 15 seconds\u003c\/li\u003e\n\u003cli\u003eAutomatic shutdown after microphone removal\u003c\/li\u003e\n\u003cli\u003eStandard support for 1\/2\" microphones\u003c\/li\u003e\n\u003cli\u003eSupports 1\" microphones by removing the adaptor\u003c\/li\u003e\n\u003cli\u003eOptional adaptor available for 1\/4\" microphones\u003c\/li\u003e\n\u003cli\u003eCompact handheld design\u003c\/li\u003e\n\u003cli\u003ePowered by standard AA batteries\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e94 dB \u0026amp; 114 dB Calibration\u003c\/h2\u003e\n\u003cp\u003eThe AWA6022A provides two selectable calibration levels:\u003c\/p\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eCalibration Level\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eTypical Use\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e94 dB @ 1 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRoutine field calibration and verification of sound level meters and noise dosimeters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e114 dB @ 1 kHz\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHigher-level calibration where required by the instrument or measurement procedure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe calibrator starts at \u003cstrong\u003e94 dB\u003c\/strong\u003e and can be switched to \u003cstrong\u003e114 dB\u003c\/strong\u003e using the 94\/114 function control.\u003c\/p\u003e\n\u003ch2\u003eClass 2 Calibration\u003c\/h2\u003e\n\u003cp\u003eThe AWA6022A complies with \u003cstrong\u003eIEC 60942:2017 Class 2\u003c\/strong\u003e and is an ideal companion for Class 2 sound measurement instruments.\u003c\/p\u003e\n\u003cp\u003eTypical applications include:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eClass 2 sound level meters\u003c\/li\u003e\n\u003cli\u003ePersonal noise dosimeters\u003c\/li\u003e\n\u003cli\u003eWorkplace noise surveys\u003c\/li\u003e\n\u003cli\u003eOccupational hygiene\u003c\/li\u003e\n\u003cli\u003eMachinery noise measurement\u003c\/li\u003e\n\u003cli\u003eEnvironmental noise surveys\u003c\/li\u003e\n\u003cli\u003eHealth and safety inspections\u003c\/li\u003e\n\u003cli\u003eGeneral acoustic measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWhere a Class 1 calibration system is required, choose the \u003cstrong\u003eAWA6021A Class 1 Sound Calibrator\u003c\/strong\u003e instead.\u003c\/p\u003e\n\u003ch2\u003eMicrophone Compatibility\u003c\/h2\u003e\n\u003cp\u003eThe standard adaptor is designed for commonly used \u003cstrong\u003e1\/2\" measurement microphones\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eThe AWA6022A can also be used with:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\" microphones\u003c\/strong\u003e – by removing the standard adaptor\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1\/4\" microphones\u003c\/strong\u003e – using the optional AWA8532 adaptor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFree-Field Microphone Correction\u003c\/h3\u003e\n\u003cp\u003eWhen calibrating a free-field microphone, a small correction may be required depending on the microphone design.\u003c\/p\u003e\n\u003cp\u003eFor a typical \u003cstrong\u003e1\/2\" free-field microphone\u003c\/strong\u003e, the specified correction at 1 kHz is -0.2 dB. Therefore, with the calibrator generating 94.0 dB, the connected measuring instrument would typically display approximately \u003cstrong\u003e93.8 dB\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp\u003eAlways use the correction specified for the particular microphone being calibrated.\u003c\/p\u003e\n\u003ch2\u003eSimple Field Operation\u003c\/h2\u003e\n\u003col\u003e\n\u003cli\u003eSwitch the AWA6022A on.\u003c\/li\u003e\n\u003cli\u003eAllow the calibration signal to stabilise.\u003c\/li\u003e\n\u003cli\u003eCarefully place the calibrator over the measurement microphone.\u003c\/li\u003e\n\u003cli\u003eWait until the indicator confirms a stable output.\u003c\/li\u003e\n\u003cli\u003ePerform or verify calibration on the connected instrument.\u003c\/li\u003e\n\u003cli\u003eSelect 114 dB if the higher calibration level is required.\u003c\/li\u003e\n\u003cli\u003eRemove the calibrator when calibration is complete.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003eWhen the microphone is removed and the calibrator cavity remains open, the AWA6022A automatically switches off after approximately five seconds.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAWA6022A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInstrument Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eClass 2 Sound Calibrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIEC 60942:2017 Class 2 \/ GB\/T 15173-2026\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound Pressure Levels\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94.0 dB \/ 114.0 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSound Pressure Level Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Frequency\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1,000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFrequency Error\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.7%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHarmonic Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤1.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOverall Distortion\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e≤3.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStabilisation Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Microphone Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1\/2\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\" Microphones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSupported with standard adaptor removed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e1\/4\" Microphones\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptional AWA8532 adaptor required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBattery\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 × AA alkaline batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMaximum Continuous Operation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApprox. 7 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.2–3.4 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e70 × 70 × 35.2 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-10°C to +50°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Humidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25–90% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAtmospheric Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e65–108 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eTypical Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eSound level meter field calibration\u003c\/li\u003e\n\u003cli\u003eNoise dosimeter calibration\u003c\/li\u003e\n\u003cli\u003eOccupational noise measurement\u003c\/li\u003e\n\u003cli\u003eWorkplace noise surveys\u003c\/li\u003e\n\u003cli\u003eEnvironmental noise surveys\u003c\/li\u003e\n\u003cli\u003eIndustrial hygiene\u003c\/li\u003e\n\u003cli\u003eMachinery and equipment noise\u003c\/li\u003e\n\u003cli\u003eHealth and safety inspections\u003c\/li\u003e\n\u003cli\u003eMeasurement microphone verification\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCalibration \u0026amp; Verification\u003c\/h2\u003e\n\u003cp\u003eFor measurements requiring traceability, the acoustic calibrator itself should also be periodically calibrated.\u003c\/p\u003e\n\u003cp\u003ePeriodic metrological calibration—typically \u003cstrong\u003eonce per year\u003c\/strong\u003e—is recommended to maintain the specified sound pressure level accuracy.\u003c\/p\u003e\n\u003ch1\u003eHelp Me Choose\u003c\/h1\u003e\n\u003ch2\u003eAWA6021A vs AWA6022A Sound Calibrators\u003c\/h2\u003e\n\u003cdiv class=\"group TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth class=\"last:pe-10\"\u003eModel\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eAccuracy\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eOutput\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eBest For \/ Why Choose It\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA6021A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94 \/ 114 dB @ 1 kHz\u003c\/td\u003e\n\u003ctd\u003eClass 1 and Class 2 sound measurement systems. \u003cstrong\u003eHighest calibration accuracy.\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA6022A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e94 \/ 114 dB @ 1 kHz\u003c\/td\u003e\n\u003ctd\u003eClass 2 meters and noise dosimeters. \u003cstrong\u003eBest-value calibration option.\u003c\/strong\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eWhich One Should I Choose?\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the AWA6022A\u003c\/strong\u003e when you primarily use Class 2 sound level meters or noise dosimeters and want a cost-effective field calibrator.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChoose the AWA6021A\u003c\/strong\u003e when you use Class 1 instruments, your procedure specifically requires Class 1 calibration, or you want one calibrator capable of supporting both Class 1 and Class 2 systems.\u003c\/p\u003e\n\u003ch6\u003e\u003cspan\u003eHelp Me Choose\u003c\/span\u003e\u003c\/h6\u003e\n\u003ch2\u003e\u003cspan\u003eSound Level Meters\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003cth\u003eVariants \/ Analysis Available\u003c\/th\u003e\n\u003cth\u003eBest For \/ Why Choose It\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA5636\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 2\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic • Integrating \/ Leq • Online Monitoring • Statistical + TWA\/Dose\u003c\/td\u003e\n\u003ctd\u003eGeneral workplace, machinery and environmental noise. Lowest-cost professional option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA5662\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrating • Statistical • TWA\/Dose • 1\/1 + 1\/3 Octave • Low\/High SPL versions\u003c\/td\u003e\n\u003ctd\u003eProfessional Class 1 noise measurement. Best-value Class 1 option.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA6228+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrating • Statistical • 1\/1 Octave • 1\/3 Octave • FFT • Reverberation • Logger • Recording • Dosimeter • GPS\u003c\/td\u003e\n\u003ctd\u003eProfessional and advanced noise measurement. Configure only the functions you need.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA6292\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eClass 1\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrating • Statistical • TWA\/Dose • 1\/1 Octave • 1\/3 Octave • Reverberation • STI\u003c\/td\u003e\n\u003ctd\u003eAdvanced environmental and architectural acoustics. Highest acoustic capability.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ch2\u003e\n\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAWA5636\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the best starting point where Class 2 accuracy is suitable.\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eStep up to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAWA5662\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e when Class 1 accuracy is required while keeping the instrument straightforward and cost-effective.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eChoose the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAWA6228+\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e where greater configuration flexibility or advanced functions such as FFT, reverberation, detailed frequency analysis or GPS are required.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"isSelectedEnd\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAWA6292\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is intended for more specialised acoustic applications including advanced frequency analysis, reverberation and STI measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSpecialist Instruments\u003c\/span\u003e\u003c\/h2\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eType\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eVersions \/ Configurations\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBest For\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eWhy Choose It\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAWA5920\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNoise Dosimeter\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingle • Multi-unit kits\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePersonal and occupational noise exposure\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eWearable shift monitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYT2001\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAcoustic Imager\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eStandard\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLeak detection, partial discharge and sound-source location\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eVisually locate sound sources\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNot sure which model you need?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Send us your application, required measurement parameters or applicable standard and our applications team can recommend the most suitable instrument and configuration.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\n\u003ch2\u003eDownloads\u003c\/h2\u003e\n\u003cp\u003eDownload product manuals and operating instructions below.\u003c\/p\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eDocument\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA5636\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/awa5636-1-instruction-manual.pdf?v=1787737081\"\u003eDownload AWA5636 Instruction Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA5662\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/awa5662-sound-level-meter-manual.pdf?v=1787799355\"\u003eDownload AWA5662 Instruction Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA6228+\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/AWA6228_sound_level_meter.pdf?v=1787792318\"\u003eDownload AWA6228+ Instruction Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA6292\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/instruction-manual-of-mode-awa6292-sound-level-meter.pdf?v=1787793608\"\u003eDownload AWA6292 Instruction Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA5920\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/awa5920-instruction-manual-v1-0-0.pdf?v=1787794919\"\u003eDownload AWA5920 Instruction Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eYT2001\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA6021A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/awa6021a-sound-calibrator-user-manual.pdf?v=1787797014\"\u003eDownload AWA6021A Class 1 Sound Calibrator User Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAWA6022A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/awa6022a-sound-calibrator-user-manual.pdf?v=1787797014\"\u003eDownload AWA6022A Class 2 Sound Calibrator User Manual\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"AIHUA","offers":[{"title":"Default Title","offer_id":46097230495935,"sku":"AWA6022A","price":6380.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/awa6022a-sound-calibrator04.jpg?v=1787797623","url":"https:\/\/inspectiontools.co.za\/products\/class-2-sound-calibrator-awa6022a","provider":"Inspection Tool Specialists","version":"1.0","type":"link"}