{"title":"Fuel, Oil \u0026 Industrial Chemical Analysis","description":"","products":[{"product_id":"cooking-oil-tester-pce-fot-10","title":"Cooking Oil Tester PCE-FOT 10","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003cspan\u003eCooking oil tester\u003c\/span\u003e with 3-digit LCD \/ Backlit \/ IP65 protected \/ Status LEDs (blue, green, red) \/ Display of PC value between 0.5% to 40% \/ Automatic switch-off function\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe cooking oil tester is a measuring device with which you can determine the quality of various types of oil. This cooking oil tester is also successfully used by food inspectors. A measurement is carried out directly in hot fat. For this, the measuring tip is held directly in a fryer or the like. Thus, fast measurement results are guaranteed. The oil temperature in °C \/ °F and the oil quality in percent PC (polar compounds) are determined within a few seconds. The PC value is a measure of the thermal-oxidative stress level of a frying oil. On the device itself, a traffic light function is installed, so that the oil quality is displayed directly in color.\u003c\/p\u003e\n\u003cp\u003eThis coooking oil tester is not only used by food inspectors, but also in gastronomy, According to the recommendations of the DGF (German Society for Fat Science) 24 percent polar components (Polar compounds) are to be regarded as a limit to the healthiness of a deep-frying fat. When old fat is used, it generally has many disadvantages. This includes influencing the taste and the associated reduced quality. In addition, it can cause strong odor and smoke, if the fat is not examined with a cooking oil tester. National regulations regarding maximum PC limits are to be observed if necessary. Since not all oils behave exactly the same, different calibrations can be stored and called up in the coooking oil tester. There are four fixed storage locations (semi-liquid, liquid, solid) as well as 6 variable storage spaces.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Measurement directly in the liquid fat\u003cbr\u003e- Prevention of health risks\u003cbr\u003e- Fast, reliable on-site measurement\u003cbr\u003e- Different calibrations can be saved\u003cbr\u003e- Adjustment of the correct frying point\u003cbr\u003e- Exact quality determination of the frying oil\u003cbr\u003e- Temperature measurement up to 200°C \/ 392°F\u003cbr\u003e- Traffic light display\u003cbr\u003e- Waterproof\u003cbr\u003e- Robust and shockproof\u003cbr\u003e- Several oil types adjustable\u003cbr\u003e- 0.5 to 40% polar parts\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eArea of application: deep-frying oils\u003c\/strong\u003e\u003cbr\u003e-\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFor determining the deep-frying oil TPM \u003c\/strong\u003e\u003cspan\u003e(Total Polar Materials) \u003c\/span\u003e\u003cstrong\u003evalue\u003c\/strong\u003e\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv class=\"tab-pane fade active in\" id=\"tab-customdata3\"\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellspacing=\"0\" border=\"0\" bgcolor=\"#FFFFFF\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"278\" valign=\"top\"\u003e\u003cspan\u003eMeasuring range temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd width=\"306\" valign=\"top\"\u003e\n\u003cspan\u003e30 ... 200°C\u003c\/span\u003e \/ 86 ... 392°F\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring accuracy temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 1.5°C \/ ± 2.7°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.5°C \/ 0.9°F\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring range oil (PC value)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.5 ... 40% polar parts  \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eMeasuring accuracy oil (PC value)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e± 3% (at 30 ... 90°C \/ 86 ... 194°F)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eResolution of oil (PC value)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e0.1%\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePower supply\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e2 x 1.5V AAA battery\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eBattery life\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eApprox. 500 measurements \/ 25 h in continuous operation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eTemperature sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003ePTC sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOil sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eCapacitive sensor\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOperating temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e0 ... 50°C \/ 32 ... 122\u003c\/span\u003e°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eStorage temperature\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003e-20 ... 70°C \/ -4 ... 158\u003c\/span\u003e°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDisplay\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eLCD, 3 digits\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eDimensions (W x D x H)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e55 x 350 x 25 mm \/ 2.2 x 13.8 x 1 in without probe\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003e185 g \/ \u0026lt; 1 lb \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003eHousing material\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eABS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003eProtection\u003c\/span\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eIP65\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003eEvaluation of the results on the \u003c\/span\u003ecooking oil tester\u003cspan\u003e PCE-FOT 10\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eOil is new and fresh (LED flashes green)       \u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cstrong\u003e\u003cspan\u003e0 ... 18.5%\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\n\u003cspan\u003eOil is in critical range (LED flashes yellow). It is recommended to replace or partially renew the oil.\u003c\/span\u003e\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003e19 ... 24%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e\u003cspan\u003eThe oil in the fryer has been used up. The set limit (factory setting 24%) is exceeded and the LED flashes red. Therefore, an exchange of the oil must be made.\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e\u003cstrong\u003e\u003cspan\u003e\u0026gt; 24%\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003ctd valign=\"top\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Cooking Oil Tester PCE-FOT 10\u003cbr\u003e1 x Transport case\u003cbr\u003e1 x User manual\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1864826\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_manual mimetitlel_EN\"\u003eManual\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1864828\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_datasheet mimetitlel_EN\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/english\/api\/getartfile?_fnr=1864831\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_certificate_ce mimetitlel_EN\"\u003eCE Certificate\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":43648161317055,"sku":"PCE-FOT 10","price":7950.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/pce-instruments-cooking-oil-tester-pce-fot-10-5989110_1864827.webp?v=1736936752"},{"product_id":"din-flow-cup-viscometer-pce-127-4","title":"DIN Flow Cup Viscometer PCE-127\/4","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eDIN flow cup \u003c\/strong\u003e\u003cstrong\u003eviscometer for measuring viscosity \/ German standard DIN 53211 \/\u003cbr\u003eCup made of anodized aluminum \/ Also available as immersion cup\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003eDIN flow cup viscometers are viscosity meters to determine the viscosity of liquids. The flow cups are often used in industry and research laboratories. Due to the form of the measuring method, however, the determination is only carried out on low-viscosity liquids, since the liquid cannot run off through the nozzles if the viscosities are too high. Liquids with Newtonian behavior therefore give the most accurate results in the flow cup. The viscosity can be determined on the basis of the flow volume and the measured time that the liquid needs to run through the nozzle from the flow cup. The start time begins when the liquid emerges at the lower edge of the nozzle. It is stopped as soon as the liquid no longer flows evenly or the liquid breaks off. In addition, there are immersion cups that are suitable for quick measurements on site; these are only immersed in the material to be measured. As soon as you lift out the cup and the liquid comes out of the nozzle, you can start timing. After completion of the measurement, it is imperative that the flow cup is cleaned, as dried-on residues can falsify the next measurement result. It should also be ensured that no pointed or sharp tools are used for cleaning. Scratches and scrapes in the flow cup viscometer also affect the result.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e- Material anodized aluminum\u003cbr\u003e- Factory calibration certificate included\u003cbr\u003e- With overflow channel\u003cbr\u003e- Meets international standards\u003cbr\u003e- Stand available as optional accessory \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003e Technical specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacity\u003c\/td\u003e\n\u003ctd\u003e100 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiameter nozzle\u003c\/td\u003e\n\u003ctd\u003e4 mm ( ± 0.02 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eDIN 53211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow time\u003c\/td\u003e\n\u003ctd\u003e25 ... 150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic viscosity (mPA * s)\u003c\/td\u003e\n\u003ctd\u003e96.2 ... 680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ecup: anodised aluminium\u003cbr\u003enozzle: stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions 127\/4\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd\u003eØ interior 50 mm\u003cbr\u003eØ exterior 85 mm\u003cbr\u003eheight 70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\"\u003eDimensions 127\/4P (immersion cup)  \u003c\/td\u003e\n\u003ctd\u003eØ interior 50 mm\u003cbr\u003eØ exterior 65 mm\u003cbr\u003eheight 78 mm\u003cbr\u003ehandle height 170 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 215 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e1 x PCE-127\/4 DIN Flow Cup Viscometer\u003cbr\u003e1 x Glass plate\u003cbr\u003e1 x Factory certificate\u003cbr\u003e1 x Instruction manual \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eN.B. Test stand not included. It can be ordered as an optional accessory (Order ID: BDG 130)\u003c\/strong\u003e \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv style=\"display:flex; gap:20px;\"\u003e\n  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-flow-cup-meter-pce-127-en.pdf?v=1734280716\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e\n    \u003cspan\u003eManual\u003c\/span\u003e\n    \u003c\/a\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-flow-cup-meter-pce-127.pdf?v=1734280715\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\" \"\u003e\n      \u003cspan\u003eDatasheet\u003c\/span\u003e\n      \u003c\/a\u003e\n\n  \u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/3hMBZlFf_PQ?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video.webp?v=1733723112\" alt=\"\"\u003e  \u003cspan\u003eVideo\u003c\/span\u003e\u003c\/a\u003e\n\n\u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/QC7mJcbHkUc?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video_quick_start.webp?v=1734280945\" alt=\"\"\u003e  \u003cspan\u003eVideo Quick Start\u003c\/span\u003e\u003c\/a\u003e\n\n\u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/lk2vPGKlrhY?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/www.pce-instruments.com\/india\/g\/mime\/custom_video_manual.gif\" alt=\"\"\u003e  \u003cspan\u003eVideo Mannual\u003c\/span\u003e\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-files\" class=\"tab-pane clear fade in\"\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":43907973710015,"sku":"PCE-127-4","price":7640.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/pce-instruments-din-flow-cup-viscometer-pce-127-4-6176633_3198971.webp?v=1736936319"},{"product_id":"analogue-dial-reading-viscometer-viscosity-meter-pce-rvi-1","title":"Analog Viscometer PCE-RVI 1","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"center\"\u003e\u003cstrong\u003ePCE-RVI 1 \u003c\/strong\u003e\u003cstrong\u003eAnalogue Dial Reading Viscometer \/ Viscosity Meter\u003cbr\u003eRotational viscosity measuring device ideal for Newtonian fluids\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp align=\"justify\"\u003ePCE-RVI 1 is an analogue viscometer or dial reading viscometer used in industrial and research applications to measure the viscosity of fluids such as paints, lacquers, inks, pastes, adhesives, plastics, greases and liquid food products. Under identical conditions, test results from an analogue viscometer are as accurate and reproducible as results from a digital viscometer. Thus, the PCE-RVI 1 analogue viscometer offers an affordable solution for viscosity measurement during product and material testing, development, production and quality control.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eBasic operation\u003c\/strong\u003e\u003cbr\u003ePrepare the liquid to be measured and put it into a glass beaker or a right angle container with a diameter no smaller than 70 mm and a height no smaller than 130 mm. Adjust the lifting screw and put the spindle into the liquid until the level mark on the spindle reaches the liquid's surface. Connect the power supply, turn on the equipment, screw the speed knob, select the velocity and relax the pointer joystick. When selecting a rotational speed of 6 or 12 rpm, the final measurement value may be read when the pointer becomes stable. When selecting 30 or 60 rpm, press the pointer joystick after pointer becoming stable, cut power supply, then read the final measurement value.\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003eOffering an adjustable rotational speed, this portable analogue viscometer:\u003cbr\u003e\u003cbr\u003e- Provides a coefficient table on top of the motor housing for on-the-spot calculations of absolute viscosity\u003cbr\u003e- Uses electric power to maintain a constant speed of either 6, 12, 30 or 60 revolutions per minute (rpm)\u003cbr\u003e- Features a built-in level and adjustable feet to ensure measurement precision\u003cbr\u003e- Includes four different rotors or spindles (spec. 1, 2, 3 and 4)\u003cbr\u003e- Comes with a protective wooden carrying case \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" width=\"600\" valign=\"bottom\" height=\"28\"\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003e\u003cbr\u003eTechnical specifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"4\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan lang=\"EN-US\" xml:lang=\"EN-US\"\u003e\u003c\/span\u003eRotational speed\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"4\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan\u003e6, 12, 30, 60\u003c\/span\u003e rpm\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"12\"\u003e\n\u003cp\u003eTorque range\u003c\/p\u003e\n\u003cp align=\"left\"\u003e\u003cspan lang=\"EN-US\" xml:lang=\"EN-US\"\u003e\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"12\"\u003e\n\u003cp align=\"left\"\u003eRotational viscometer (RV)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"12\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan lang=\"EN-US\" xml:lang=\"EN-US\"\u003e\u003cstrong\u003eViscosity range\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"12\"\u003e\n\u003cp align=\"left\"\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"4\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan lang=\"EN-US\" xml:lang=\"EN-US\"\u003e\u003c\/span\u003eMillipascal-second (mPa.s)\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"4\"\u003e\n\u003cp align=\"left\"\u003e10 ... 100,000 mPa.s (= cP) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"12\"\u003e\n\u003cp align=\"left\"\u003e\u003cspan lang=\"EN-US\" xml:lang=\"EN-US\"\u003e\u003cstrong\u003eGeneral specifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd width=\"600\" valign=\"top\" height=\"12\"\u003e\n\u003cp align=\"left\"\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003eAccuracy\u003c\/td\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003e± 5% full scale (FS) in Newtonian fluids\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003ePower supply\u003c\/td\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003e110 V or 220 V  \/ 50 or 60 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003eApprox. dimensions\u003c\/td\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003e300 x 300 x 450 mm \/ 11.8 x 11.8 x 17.7 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003eApprox. weight\u003c\/td\u003e\n\u003ctd valign=\"top\" height=\"1\"\u003e\n\u003cp\u003e1.5 kg \/ 3.4 lbs\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" valign=\"top\" height=\"1\"\u003e\n\u003cdiv align=\"justify\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cp align=\"justify\"\u003e1 x PCE-RVI 1 analogue dial reading viscometer \/ viscosity meter\u003cbr\u003e4 x Spindles\u003cbr\u003e1 x Protection bracket\u003cbr\u003e1 x Bracket\u003cbr\u003e3 x Adjusting screws\u003cbr\u003e1 x Carrying case\u003cbr\u003e1 x User manual\u003c\/p\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch3 class=\"headline\"\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv style=\"display:flex; gap:20px;\"\u003e\n  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/manual-viscometer-pce-rvi1.pdf?v=1734281179\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e\n    \u003cspan\u003eManual\u003c\/span\u003e\n    \u003c\/a\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-pce-rvi-1.pdf?v=1734281178\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\" \"\u003e\n      \u003cspan\u003eDatasheet\u003c\/span\u003e\n      \u003c\/a\u003e  \n\n  \u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/WMOipesWtp4?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video_quick_start.webp?v=1734280945\" alt=\"\"\u003e  \u003cspan\u003eVideo Quick Start\u003c\/span\u003e\u003c\/a\u003e\n\n\u003ca class=\"iframe-large\" href=\"https:\/\/www.youtube-nocookie.com\/embed\/qEJzspacZas?autoplay=1\u0026amp;rel=0\u0026amp;showinfo=0\u0026amp;\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_video_manual.webp?v=1734281335\" alt=\"\"\u003e  \u003cspan\u003eVideo Mannual\u003c\/span\u003e\u003c\/a\u003e\n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":43907976921279,"sku":"PCE-RVI-1","price":27120.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/pce-instruments-analogue-dial-reading-viscometer-viscosity-meter-pce-rvi-1-6162601_3086903.webp?v=1736936318"},{"product_id":"iso-flow-cup-viscometer-pce-128-3","title":"ISO Flow Cup Viscometer PCE-128\/3","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eISO flow cup \u003c\/strong\u003e\u003cstrong\u003eviscometer for measuring viscosity \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eInternational standard DIN 53224 \/ Cup made of anodized aluminum\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003eISO flow cup viscometers are suitable for determining the flow time of Newtonian \/ near-Newtonian liquids and are often used in laboratories and industrial production. For handling, the nozzle must be closed and the material to be measured must be poured into the flow cup. By placing the glass plate on the cup, you create a vacuum, which enables the cup to be placed in the tripod for time measurement. When the glass plate is then pulled from the flow cup, the measurement can be started. As soon as the flow comes to a standstill, the time must be stopped. For a relative value, this method is perfectly adequate in many areas. To ensure the accuracy of the cup, it is important to clean it after each use. It is important to ensure that the surface inside the cup is not damaged. Any scratches or dried material residues will affect the further measurements.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e- Highly polished and finely machined for a\u003cbr\u003e   high discharge accuracy\u003cbr\u003e- Factory calibration certificate included\u003cbr\u003e- With overflow channel\u003cbr\u003e- Complies with international standards\u003cbr\u003e- Stand available as optional accessory \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMeasuring range (cSt)  \u003c\/td\u003e\n\u003ctd\u003eFlow time (sec.)\u003c\/td\u003e\n\u003ctd\u003eOutlet nozzle Ø (mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCE-128\/3  \u003c\/td\u003e\n\u003ctd\u003e7 ... 42 cSt\u003c\/td\u003e\n\u003ctd\u003e25 ... 150 s\u003c\/td\u003e\n\u003ctd\u003e3.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMaterial\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ecup: anodized aluminum\u003cbr\u003enozzle: stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eStandards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eISO 2431, DIN 53224, EN 535, ASTM D5125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eØ inside 50 mm\u003cbr\u003eØ outside 85 mm\u003cbr\u003eheight 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eca. 310 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e1 x ISO Flow Cup Viscometer PCE-128\/3\u003cbr\u003e1 x Glass plate\u003cbr\u003e1 x Factory calibration certificate\u003cbr\u003e1 x Instruction manual \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv style=\"display:flex; gap:20px;\"\u003e\n  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-viscometer-pce-128-en.pdf?v=1734281654\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e\n    \u003cspan\u003eManual\u003c\/span\u003e\n    \u003c\/a\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-viscometer-pce-128.pdf?v=1734281653\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\" \"\u003e\n      \u003cspan\u003eDatasheet\u003c\/span\u003e\n      \u003c\/a\u003e  \n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-files\" class=\"tab-pane clear fade in\"\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":43907980394687,"sku":"PCE-128-3","price":7520.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/pce-instruments-din-flow-cup-viscometer-pce-127-4-6176633_3198971.webp?v=1736936319"},{"product_id":"ford-flow-cup-viscometer-pce-125-2","title":"Ford Flow Cup Viscometer PCE-125\/2","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eISO flow cup \u003c\/strong\u003e\u003cstrong\u003eviscometer for measuring viscosity \/\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eInternational standard DIN 53224 \/ Cup made of anodized aluminum\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv align=\"justify\"\u003eISO flow cup viscometers are suitable for determining the flow time of Newtonian \/ near-Newtonian liquids and are often used in laboratories and industrial production. For handling, the nozzle must be closed and the material to be measured must be poured into the flow cup. By placing the glass plate on the cup, you create a vacuum, which enables the cup to be placed in the tripod for time measurement. When the glass plate is then pulled from the flow cup, the measurement can be started. As soon as the flow comes to a standstill, the time must be stopped. For a relative value, this method is perfectly adequate in many areas. To ensure the accuracy of the cup, it is important to clean it after each use. It is important to ensure that the surface inside the cup is not damaged. Any scratches or dried material residues will affect the further measurements.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata2\" class=\"tab-pane clear fade in\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e- Highly polished and finely machined for a\u003cbr\u003e   high discharge accuracy\u003cbr\u003e- Factory calibration certificate included\u003cbr\u003e- With overflow channel\u003cbr\u003e- Complies with international standards\u003cbr\u003e- Stand available as optional accessory \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata3\" class=\"tab-pane clear fade in\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003e\u003cstrong\u003eTechnical specifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMeasuring range (cSt)  \u003c\/td\u003e\n\u003ctd\u003eFlow time (sec.)\u003c\/td\u003e\n\u003ctd\u003eOutlet nozzle Ø (mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePCE-128\/3  \u003c\/td\u003e\n\u003ctd\u003e7 ... 42 cSt\u003c\/td\u003e\n\u003ctd\u003e25 ... 150 s\u003c\/td\u003e\n\u003ctd\u003e3.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eMaterial\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003ecup: anodized aluminum\u003cbr\u003enozzle: stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eStandards\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eISO 2431, DIN 53224, EN 535, ASTM D5125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eDimensions\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eØ inside 50 mm\u003cbr\u003eØ outside 85 mm\u003cbr\u003eheight 85 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eWeight\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eca. 310 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-customdata4\" class=\"tab-pane clear fade in\"\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e1 x ISO Flow Cup Viscometer PCE-128\/3\u003cbr\u003e1 x Glass plate\u003cbr\u003e1 x Factory calibration certificate\u003cbr\u003e1 x Instruction manual \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"tab-files\" class=\"tab-pane clear fade in\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv style=\"display:flex; gap:20px;\"\u003e\n  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-viscometer-pce-125-en.pdf?v=1734281906\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e\n    \u003cspan\u003eManual\u003c\/span\u003e\n    \u003c\/a\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-viscometer-pce-125-2-5.pdf?v=1734281906\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\" \"\u003e\n      \u003cspan\u003eDatasheet\u003c\/span\u003e\n      \u003c\/a\u003e  \n  \u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":43907987341503,"sku":"PCE-125-2","price":7640.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/pce-instruments-ford-flow-cup-viscometer-pce-125-2-6176643_3199043.webp?v=1736936316"},{"product_id":"ford-flow-cup-viscometer-pce-125-3","title":"Ford Flow Cup Viscometer PCE-125\/3","description":"\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv id=\"tab-customdata1\" class=\"tab-pane clear fade in active\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003cdiv class=\"tab-content-off\"\u003e\n\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch2 class=\"headline\"\u003eDescription\u003c\/h2\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eFord Flow Cup \u003c\/strong\u003e\u003cstrong\u003eViscometer \/ International Standard ASTM D1200, D333 and D365\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMachine-made, anodized aluminum with exchangeable stainless steel nozzle\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eFord flow cup viscometers are used to measure liquids quickly and easily in order to determine their viscosity. However, it must be taken into account that this is only possible with less viscous liquids. Viscous pastes and other substances with a high viscosity are not suitable for measurement with a flow cup. The structure of a flow cup is standardized according to a DIN and is therefore always the same. It consists of a cylindrical hollow body which in most cases ends in an exchangeable nozzle. The openings of the nozzles, like the cup, are subject to a respective DIN standard.\u003cbr\u003e\u003cbr\u003eMeasurement is carried out as follows. First you hold the nozzle underneath closed and fill in the substance to be measured. Make sure that the cup is filled to the top. An overflow channel prevents the measurement from being falsified by liquid running off the sides. Then the glass plate is pushed over the edge of the cup to remove any excess material. You can now open the nozzle again. The resulting negative pressure keeps the material in the cup. If you now pull the glass plate horizontally from the beaker, you have to activate the stopwatch. As soon as the outflowing stream breaks for the first time, you have to stop the time and note it down.\u003cbr\u003e\u003cbr\u003eWhen using a flow cup, it is particularly important to ensure that it is cleaned thoroughly after each measurement, as residues in the nozzle and cup can falsify the further results. Even deep or many scratches in the cup can lead to measurement uncertainties in the result, since the removed material changes the volume of the cup and thus no longer complies with the specified DIN standard.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch3 class=\"headline\"\u003eHighlights\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e- Anodized aluminum - satin finish\u003cbr\u003e- Including factory calibration certificate\u003cbr\u003e- Overflow channel for clean work\u003cbr\u003e- Complies with international standards\u003cbr\u003e- Stand available as optional accessory \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eSpecification\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical specifications\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePCE-125\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner vertical height\u003c\/td\u003e\n\u003ctd\u003e43 ±0.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNozzle inside Ø\u003c\/td\u003e\n\u003ctd\u003e3.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNozzle outside Ø\u003c\/td\u003e\n\u003ctd\u003e5.5 ±0.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range (mm²\/s)  \u003c\/td\u003e\n\u003ctd\u003e49 ... 220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow time (sec.) ±0.2\u003c\/td\u003e\n\u003ctd\u003e25 ... 105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ecup: anodized aluminum\u003cbr\u003enozzle: stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eInternational Standard ASTM D1200, D333 und D365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension\u003c\/td\u003e\n\u003ctd\u003eØ inside 50 mm\u003cbr\u003eØ outside 85 mm\u003cbr\u003eheight 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eca. 320 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch3 class=\"headline\"\u003eDelivery Scope\u003c\/h3\u003e\n\u003cdiv class=\"usertext\"\u003e1 x PCE-125\/3 Ford Flow Cup Viscometer\u003cbr\u003e1 x Factory calibration certificate\u003cbr\u003e1 x Glass plate\u003cbr\u003e1 x User manual \u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch3 class=\"headline\"\u003e\n\u003cbr\u003eDownloads\u003c\/h3\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv style=\"display:flex; gap:20px;\"\u003e\n  \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/man-viscometer-pce-125-en_12a069f8-1909-4673-a614-33cfa9b92253.pdf?v=1734282407\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_manual.webp?v=1733642254\" alt=\"\"\u003e\n    \u003cspan\u003eManual\u003c\/span\u003e\n    \u003c\/a\u003e\n    \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/datasheet-viscometer-pce-125-2-5_23c51756-a2dd-4a37-a9ae-0fdbd4a0181a.pdf?v=1734282408\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/custom_datasheet.webp?v=1733642254\" alt=\" \"\u003e\n      \u003cspan\u003eDatasheet\u003c\/span\u003e\n      \u003c\/a\u003e  \n  \u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":43907995107519,"sku":"PCE-125-3","price":7640.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/pce-instruments-ford-flow-cup-viscometer-pce-125-3-6176649_3199073.webp?v=1736936315"},{"product_id":"ford-flow-cup-meter-pce-125-4","title":"Ford Flow Cup Viscometer PCE-125\/4","description":"\u003cdiv class=\"tab-pane clear fade in active\" id=\"tab-customdata1\"\u003e\n\u003ch1 class=\"headline\"\u003eDescription\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003cdiv align=\"center\"\u003e\n\u003cstrong\u003eFord Flow Cup Meter \/ International Standard ASTM D1200, D333 and D365\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eMachine-made, anodized aluminum with exchangeable stainless steel nozzle\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cbr\u003e\n\u003cdiv align=\"justify\"\u003eFord flow cup meters are used to measure liquids quickly and easily in order to determine their viscosity. However, it must be taken into account that this is only possible with less viscous liquids. Viscous pastes and other substances with a high viscosity are not suitable for measurement with a flow cup meter. The structure of a flow cup meter is standardized according to a DIN and is therefore always the same. It consists of a cylindrical hollow body which in most cases ends in an exchangeable nozzle. The openings of the nozzles, like the cup, are subject to a respective DIN standard.\u003cbr\u003e\u003cbr\u003eMeasurement is carried out as follows. First you hold the nozzle underneath closed and fill in the substance to be measured. Make sure that the cup is filled to the top. An overflow channel prevents the measurement from being falsified by liquid running off the sides. Then the glass plate is pushed over the edge of the cup to remove any excess material. You can now open the nozzle again. The resulting negative pressure keeps the material in the cup. If you now pull the glass plate horizontally from the beaker, you have to activate the stopwatch. As soon as the outflowing stream breaks for the first time, you have to stop the time and note it down.\u003cbr\u003e\u003cbr\u003eWhen using a flow cup meter, it is particularly important to ensure that it is cleaned thoroughly after each measurement, as residues in the nozzle and cup can falsify the further results. Even deep or many scratches in the cup can lead to measurement uncertainties in the result, since the removed material changes the volume of the cup and thus no longer complies with the specified DIN standard.\u003c\/div\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata2\"\u003e\n\u003ch1 class=\"headline\"\u003eHighlights\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e- Anodized aluminum - satin finish\u003cbr\u003e- Including factory calibration certificate\u003cbr\u003e- Overflow channel for clean work\u003cbr\u003e- Complies with international standards\u003cbr\u003e- Stand available as optional accessory\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata3\"\u003e\n\u003ch1 class=\"headline\"\u003eSpecification\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\u003cstrong\u003eTechnical specifications\u003cbr\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePCE-125\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInner vertical height\u003c\/td\u003e\n\u003ctd\u003e43 ±0.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNozzle inside Ø\u003c\/td\u003e\n\u003ctd\u003e4.1 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNozzle outside Ø\u003c\/td\u003e\n\u003ctd\u003e6.0 ±0.5mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring range (mm²\/s)  \u003c\/td\u003e\n\u003ctd\u003e70 ... 370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow time (sec.) ±0.2\u003c\/td\u003e\n\u003ctd\u003e20 ... 105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003ecup: anodized aluminum\u003cbr\u003enozzle: stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eInternational Standard ASTM D1200, D333 und D365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension\u003c\/td\u003e\n\u003ctd\u003eØ inside 50 mm\u003cbr\u003eØ outside 85 mm\u003cbr\u003eheight 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eca. 320 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-customdata4\"\u003e\n\u003ch1 class=\"headline\"\u003eDelivery Scope\u003c\/h1\u003e\n\u003cdiv class=\"usertext\"\u003e1 x Ford Flow Cup Meter PCE-125\/4\u003cbr\u003e1 x Factory calibration certificate\u003cbr\u003e1 x Glass plate\u003cbr\u003e1 x User manual\u003cbr class=\"clear\"\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab-pane clear fade in\" id=\"tab-files\"\u003e\n\u003ch1 class=\"headline\"\u003eDownloads\u003c\/h1\u003e\n\u003cdiv class=\"pkdownloads\"\u003e\n\u003cdiv\u003e\n\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/us\/api\/getartfile?_fnr=1628221\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cimg class=\"lazy\" width=\"82\" height=\"67\" src=\"https:\/\/www.pce-instruments.com\/us\/g\/mime\/custom_manual.US.gif\" data-original=\"\/us\/g\/mime\/custom_manual.US.gif\" alt=\"man-viscometer-pce-125-en.pdf\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_manual mimetitlel_US\"\u003eManual\u003c\/span\u003e\u003c\/a\u003e\u003ca class=\"\" href=\"https:\/\/www.pce-instruments.com\/us\/api\/getartfile?_fnr=1628223\u0026amp;_dsp=inline\" target=\"_blank\"\u003e\u003cimg class=\"lazy\" width=\"82\" height=\"67\" src=\"https:\/\/www.pce-instruments.com\/us\/g\/mime\/custom_datasheet.US.gif\" data-original=\"\/us\/g\/mime\/custom_datasheet.US.gif\" alt=\"datasheet-viscometer-pce-125-2-5.pdf\"\u003e\u003cbr\u003e\u003cspan class=\"mimetitle mimetitlet_custom_datasheet mimetitlel_US\"\u003eDatasheet\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"PCE","offers":[{"title":"Default Title","offer_id":44460099928255,"sku":"PCE-125-4","price":5880.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/pce-instruments-ford-flow-cup-meter-pce-125-4-5957324_1628220.webp?v=1755073391"},{"product_id":"portable-octane-meter-cetane-number-tester-for-gasoline-diesel-fuels-shatox-sx-150-sx-250-sx-300","title":"Octane \u0026 Cetane Fuel Quality Tester SX-150","description":"\u003ch2 data-start=\"549\" data-end=\"573\"\u003eProduct Description\u003c\/h2\u003e\n\u003cp data-start=\"574\" data-end=\"832\"\u003eThe \u003cstrong data-start=\"578\" data-end=\"632\"\u003e SX Series Portable Octane and Cetane Meters\u003c\/strong\u003e are advanced handheld analyzers designed for \u003cstrong data-start=\"678\" data-end=\"710\"\u003efuel and oil quality testing\u003c\/strong\u003e. These instruments provide fast, accurate, and non-destructive analysis of gasoline, diesel, biodiesel, and lubricants.\u003c\/p\u003e\n\u003cp data-start=\"834\" data-end=\"1123\"\u003eBuilt on high-precision microprocessor technology, the SX series allows real-time quality evaluation in the field or laboratory. Each model supports \u003cstrong data-start=\"983\" data-end=\"1067\"\u003eoctane (ASTM D 2699\/2700) and cetane (ASTM D 4737\/D 613\/EN ISO 5165) measurement\u003c\/strong\u003e, with additional capabilities depending on the model.\u003c\/p\u003e\n\u003cp data-start=\"1125\" data-end=\"1278\"\u003eCompact, durable, and PC-connectable via USB, the SX series is trusted worldwide by oil companies, refineries, laboratories, and quality control teams.\u003c\/p\u003e\n\u003chr data-start=\"1280\" data-end=\"1283\"\u003e\n\u003ch2 data-start=\"1285\" data-end=\"1315\"\u003eKey Features (All Models)\u003c\/h2\u003e\n\u003cul data-start=\"1316\" data-end=\"1676\"\u003e\n\u003cli data-start=\"1316\" data-end=\"1406\"\u003e\n\u003cp data-start=\"1318\" data-end=\"1406\"\u003eMeasures \u003cstrong data-start=\"1327\" data-end=\"1349\"\u003eoctane number (ON)\u003c\/strong\u003e of gasoline and \u003cstrong data-start=\"1366\" data-end=\"1388\"\u003ecetane number (CN)\u003c\/strong\u003e of diesel fuels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1407\" data-end=\"1465\"\u003e\n\u003cp data-start=\"1409\" data-end=\"1465\"\u003eCompliance with international standards (ASTM, EN ISO)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1466\" data-end=\"1505\"\u003e\n\u003cp data-start=\"1468\" data-end=\"1505\"\u003eQuick measurement time: 1–5 seconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1506\" data-end=\"1555\"\u003e\n\u003cp data-start=\"1508\" data-end=\"1555\"\u003eBuilt-in memory and USB export (.xlsx \/ .txt)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1556\" data-end=\"1620\"\u003e\n\u003cp data-start=\"1558\" data-end=\"1620\"\u003e8-key anti-glare keyboard, wear-resistant and chemical-proof\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1621\" data-end=\"1676\"\u003e\n\u003cp data-start=\"1623\" data-end=\"1676\"\u003ePortable and field-ready, with ≥6 years useful life\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1678\" data-end=\"1681\"\u003e\n\u003ch2 data-start=\"1683\" data-end=\"1713\"\u003eModel-Specific Highlights\u003c\/h2\u003e\n\u003cp data-start=\"1715\" data-end=\"1776\"\u003e\u003cstrong data-start=\"1715\" data-end=\"1737\"\u003eSX-150 (Essential)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"1777\" data-end=\"1955\"\u003e\n\u003cli data-start=\"1777\" data-end=\"1892\"\u003e\n\u003cp data-start=\"1779\" data-end=\"1892\"\u003eTests: Octane (ON), Cetane (CN), Cold Filter Plugging Point (CFPP), Gasoline breakdown time, Kerosene in diesel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1893\" data-end=\"1955\"\u003e\n\u003cp data-start=\"1895\" data-end=\"1955\"\u003eCompact entry-level model for standard fuel quality checks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"1957\" data-end=\"2021\"\u003e\u003cstrong data-start=\"1957\" data-end=\"1982\"\u003eSX-250 (Professional)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2022\" data-end=\"2182\"\u003e\n\u003cli data-start=\"2022\" data-end=\"2055\"\u003e\n\u003cp data-start=\"2024\" data-end=\"2055\"\u003eIncludes all SX-150 functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2056\" data-end=\"2130\"\u003e\n\u003cp data-start=\"2058\" data-end=\"2130\"\u003eAdds: Motor oil purity, dielectric permeability (Eps), water in diesel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2131\" data-end=\"2182\"\u003e\n\u003cp data-start=\"2133\" data-end=\"2182\"\u003eIdeal for broader oil \u0026amp; diesel quality analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp data-start=\"2184\" data-end=\"2244\"\u003e\u003cstrong data-start=\"2184\" data-end=\"2205\"\u003eSX-300 (Advanced)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-start=\"2245\" data-end=\"2530\"\u003e\n\u003cli data-start=\"2245\" data-end=\"2278\"\u003e\n\u003cp data-start=\"2247\" data-end=\"2278\"\u003eIncludes all SX-250 functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2279\" data-end=\"2463\"\u003e\n\u003cp data-start=\"2281\" data-end=\"2463\"\u003eAdds: Antiknock additive detection, engine oil base number, mechanical impurities, transformer oil breakdown voltage, dielectric dissipation, fuel oil conductivity, oil resistivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2464\" data-end=\"2530\"\u003e\n\u003cp data-start=\"2466\" data-end=\"2530\"\u003eBest choice for laboratories and advanced testing requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 data-start=\"257\" data-end=\"300\"\u003eSX Series Capability Comparison\u003c\/h2\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"302\" data-end=\"1403\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"302\" data-end=\"359\"\u003e\n\u003ctr data-start=\"302\" data-end=\"359\"\u003e\n\u003cth data-start=\"302\" data-end=\"319\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"304\" data-end=\"318\"\u003eCapability\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"319\" data-end=\"332\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"321\" data-end=\"331\"\u003eSX-150\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"332\" data-end=\"345\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"334\" data-end=\"344\"\u003eSX-250\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"345\" data-end=\"359\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"347\" data-end=\"357\"\u003eSX-300\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"418\" data-end=\"1403\"\u003e\n\u003ctr data-start=\"418\" data-end=\"492\"\u003e\n\u003ctd data-start=\"418\" data-end=\"479\" data-col-size=\"md\"\u003eDetermining octane numbers for gasoline (ASTM D 2699\/2700)\u003c\/td\u003e\n\u003ctd data-start=\"479\" data-end=\"483\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"483\" data-end=\"487\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"487\" data-end=\"492\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"493\" data-end=\"583\"\u003e\n\u003ctd data-start=\"493\" data-end=\"570\" data-col-size=\"md\"\u003eDetermining cetane numbers for diesel fuel (ASTM D 4737\/D 613\/EN ISO 5165)\u003c\/td\u003e\n\u003ctd data-start=\"570\" data-end=\"574\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"574\" data-end=\"578\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"578\" data-end=\"583\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"584\" data-end=\"642\"\u003e\n\u003ctd data-start=\"584\" data-end=\"629\" data-col-size=\"md\"\u003eCold filter plugging point and diesel type\u003c\/td\u003e\n\u003ctd data-start=\"629\" data-end=\"633\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"633\" data-end=\"637\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"637\" data-end=\"642\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"643\" data-end=\"693\"\u003e\n\u003ctd data-start=\"643\" data-end=\"680\" data-col-size=\"md\"\u003eContent of kerosene in diesel fuel\u003c\/td\u003e\n\u003ctd data-start=\"680\" data-end=\"684\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"684\" data-end=\"688\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"688\" data-end=\"693\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"694\" data-end=\"765\"\u003e\n\u003ctd data-start=\"694\" data-end=\"752\" data-col-size=\"md\"\u003ePetrol breakdown time (oxidative stability, ASTM D 525)\u003c\/td\u003e\n\u003ctd data-start=\"752\" data-end=\"756\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"756\" data-end=\"760\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"760\" data-end=\"765\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"766\" data-end=\"813\"\u003e\n\u003ctd data-start=\"766\" data-end=\"800\" data-col-size=\"md\"\u003eContent of water in diesel fuel\u003c\/td\u003e\n\u003ctd data-start=\"800\" data-end=\"804\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"804\" data-end=\"808\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"808\" data-end=\"813\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"814\" data-end=\"867\"\u003e\n\u003ctd data-start=\"814\" data-end=\"854\" data-col-size=\"md\"\u003eLevel of engine \u0026amp; machine oil clarity\u003c\/td\u003e\n\u003ctd data-start=\"854\" data-end=\"858\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"858\" data-end=\"862\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"862\" data-end=\"867\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"868\" data-end=\"929\"\u003e\n\u003ctd data-start=\"868\" data-end=\"916\" data-col-size=\"md\"\u003eDielectric permeability of oil products (Eps)\u003c\/td\u003e\n\u003ctd data-start=\"916\" data-end=\"920\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"920\" data-end=\"924\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003ctd data-start=\"924\" data-end=\"929\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"930\" data-end=\"986\"\u003e\n\u003ctd data-start=\"930\" data-end=\"973\" data-col-size=\"md\"\u003eDetermining cetane numbers for biodiesel\u003c\/td\u003e\n\u003ctd data-start=\"973\" data-end=\"977\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"977\" data-end=\"981\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"981\" data-end=\"986\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"987\" data-end=\"1029\"\u003e\n\u003ctd data-start=\"987\" data-end=\"1016\" data-col-size=\"md\"\u003eContent of oil in gasoline\u003c\/td\u003e\n\u003ctd data-start=\"1016\" data-end=\"1020\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1020\" data-end=\"1024\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1024\" data-end=\"1029\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1030\" data-end=\"1086\"\u003e\n\u003ctd data-start=\"1030\" data-end=\"1073\" data-col-size=\"md\"\u003eContent of antiknock compounds in petrol\u003c\/td\u003e\n\u003ctd data-start=\"1073\" data-end=\"1077\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1077\" data-end=\"1081\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1081\" data-end=\"1086\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1087\" data-end=\"1141\"\u003e\n\u003ctd data-start=\"1087\" data-end=\"1128\" data-col-size=\"md\"\u003eTransformer oil dielectric dissipation\u003c\/td\u003e\n\u003ctd data-start=\"1128\" data-end=\"1132\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1132\" data-end=\"1136\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1136\" data-end=\"1141\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1142\" data-end=\"1191\"\u003e\n\u003ctd data-start=\"1142\" data-end=\"1178\" data-col-size=\"md\"\u003eTransformer oil breakdown voltage\u003c\/td\u003e\n\u003ctd data-start=\"1178\" data-end=\"1182\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1182\" data-end=\"1186\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1186\" data-end=\"1191\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1192\" data-end=\"1229\"\u003e\n\u003ctd data-start=\"1192\" data-end=\"1216\" data-col-size=\"md\"\u003eFuel oil conductivity\u003c\/td\u003e\n\u003ctd data-start=\"1216\" data-end=\"1220\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1220\" data-end=\"1224\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1224\" data-end=\"1229\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1230\" data-end=\"1262\"\u003e\n\u003ctd data-start=\"1230\" data-end=\"1249\" data-col-size=\"md\"\u003eEngine oil grade\u003c\/td\u003e\n\u003ctd data-start=\"1249\" data-end=\"1253\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1253\" data-end=\"1257\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1257\" data-end=\"1262\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1263\" data-end=\"1301\"\u003e\n\u003ctd data-start=\"1263\" data-end=\"1288\" data-col-size=\"md\"\u003eEngine oil base number\u003c\/td\u003e\n\u003ctd data-start=\"1288\" data-end=\"1292\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1292\" data-end=\"1296\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1296\" data-end=\"1301\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1302\" data-end=\"1349\"\u003e\n\u003ctd data-start=\"1302\" data-end=\"1336\" data-col-size=\"md\"\u003eOil products volume resistivity\u003c\/td\u003e\n\u003ctd data-start=\"1336\" data-end=\"1340\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1340\" data-end=\"1344\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1344\" data-end=\"1349\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1350\" data-end=\"1403\"\u003e\n\u003ctd data-start=\"1350\" data-end=\"1390\" data-col-size=\"md\"\u003eMechanical impurities in oil products\u003c\/td\u003e\n\u003ctd data-start=\"1390\" data-end=\"1394\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1394\" data-end=\"1398\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"1398\" data-end=\"1403\" data-col-size=\"sm\"\u003e✔\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"1405\" data-end=\"1408\"\u003e\n\u003ch2 data-start=\"1410\" data-end=\"1437\"\u003eMeasurement \u0026amp; Accuracy\u003c\/h2\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1439\" data-end=\"2182\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1439\" data-end=\"1495\"\u003e\n\u003ctr data-start=\"1439\" data-end=\"1495\"\u003e\n\u003cth data-start=\"1439\" data-end=\"1455\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1441\" data-end=\"1454\"\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1455\" data-end=\"1468\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1457\" data-end=\"1467\"\u003eSX-150\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1468\" data-end=\"1481\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1470\" data-end=\"1480\"\u003eSX-250\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"1481\" data-end=\"1495\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"1483\" data-end=\"1493\"\u003eSX-300\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1553\" data-end=\"2182\"\u003e\n\u003ctr data-start=\"1553\" data-end=\"1612\"\u003e\n\u003ctd data-start=\"1553\" data-end=\"1575\" data-col-size=\"sm\"\u003eOctane number range\u003c\/td\u003e\n\u003ctd data-start=\"1575\" data-end=\"1587\" data-col-size=\"sm\"\u003e40–135 ON\u003c\/td\u003e\n\u003ctd data-start=\"1587\" data-end=\"1599\" data-col-size=\"sm\"\u003e40–135 ON\u003c\/td\u003e\n\u003ctd data-start=\"1599\" data-end=\"1612\" data-col-size=\"sm\"\u003e40–135 ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1613\" data-end=\"1662\"\u003e\n\u003ctd data-start=\"1613\" data-end=\"1631\" data-col-size=\"sm\"\u003eOctane accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1631\" data-end=\"1641\" data-col-size=\"sm\"\u003e±0.5 ON\u003c\/td\u003e\n\u003ctd data-start=\"1641\" data-end=\"1651\" data-col-size=\"sm\"\u003e±0.5 ON\u003c\/td\u003e\n\u003ctd data-start=\"1651\" data-end=\"1662\" data-col-size=\"sm\"\u003e±0.5 ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1663\" data-end=\"1722\"\u003e\n\u003ctd data-start=\"1663\" data-end=\"1685\" data-col-size=\"sm\"\u003eCetane number range\u003c\/td\u003e\n\u003ctd data-start=\"1685\" data-end=\"1697\" data-col-size=\"sm\"\u003e20–100 CN\u003c\/td\u003e\n\u003ctd data-start=\"1697\" data-end=\"1709\" data-col-size=\"sm\"\u003e20–100 CN\u003c\/td\u003e\n\u003ctd data-start=\"1709\" data-end=\"1722\" data-col-size=\"sm\"\u003e20–100 CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1723\" data-end=\"1772\"\u003e\n\u003ctd data-start=\"1723\" data-end=\"1741\" data-col-size=\"sm\"\u003eCetane accuracy\u003c\/td\u003e\n\u003ctd data-start=\"1741\" data-end=\"1751\" data-col-size=\"sm\"\u003e±1.0 CN\u003c\/td\u003e\n\u003ctd data-start=\"1751\" data-end=\"1761\" data-col-size=\"sm\"\u003e±1.0 CN\u003c\/td\u003e\n\u003ctd data-start=\"1761\" data-end=\"1772\" data-col-size=\"sm\"\u003e±1.0 CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1773\" data-end=\"1839\"\u003e\n\u003ctd data-start=\"1773\" data-end=\"1808\" data-col-size=\"sm\"\u003eCetane parallel difference limit\u003c\/td\u003e\n\u003ctd data-start=\"1808\" data-end=\"1818\" data-col-size=\"sm\"\u003e±0.5 CN\u003c\/td\u003e\n\u003ctd data-start=\"1818\" data-end=\"1828\" data-col-size=\"sm\"\u003e±0.5 CN\u003c\/td\u003e\n\u003ctd data-start=\"1828\" data-end=\"1839\" data-col-size=\"sm\"\u003e±0.5 CN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1840\" data-end=\"1917\"\u003e\n\u003ctd data-start=\"1840\" data-end=\"1874\" data-col-size=\"sm\"\u003ePetrol oxidation breakdown time\u003c\/td\u003e\n\u003ctd data-start=\"1874\" data-end=\"1888\" data-col-size=\"sm\"\u003e50–2400 min\u003c\/td\u003e\n\u003ctd data-start=\"1888\" data-end=\"1902\" data-col-size=\"sm\"\u003e50–2400 min\u003c\/td\u003e\n\u003ctd data-start=\"1902\" data-end=\"1917\" data-col-size=\"sm\"\u003e50–2400 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1918\" data-end=\"1975\"\u003e\n\u003ctd data-start=\"1918\" data-end=\"1947\" data-col-size=\"sm\"\u003eBreakdown time error limit\u003c\/td\u003e\n\u003ctd data-start=\"1947\" data-end=\"1956\" data-col-size=\"sm\"\u003e10 min\u003c\/td\u003e\n\u003ctd data-start=\"1956\" data-end=\"1965\" data-col-size=\"sm\"\u003e10 min\u003c\/td\u003e\n\u003ctd data-start=\"1965\" data-end=\"1975\" data-col-size=\"sm\"\u003e10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1976\" data-end=\"2024\"\u003e\n\u003ctd data-start=\"1976\" data-end=\"2002\" data-col-size=\"sm\"\u003eDiesel pour point error\u003c\/td\u003e\n\u003ctd data-start=\"2002\" data-end=\"2009\" data-col-size=\"sm\"\u003e±5°C\u003c\/td\u003e\n\u003ctd data-start=\"2009\" data-end=\"2016\" data-col-size=\"sm\"\u003e±5°C\u003c\/td\u003e\n\u003ctd data-start=\"2016\" data-end=\"2024\" data-col-size=\"sm\"\u003e±5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2025\" data-end=\"2087\"\u003e\n\u003ctd data-start=\"2025\" data-end=\"2062\" data-col-size=\"sm\"\u003eKerosene detection range in diesel\u003c\/td\u003e\n\u003ctd data-start=\"2062\" data-end=\"2070\" data-col-size=\"sm\"\u003e0–95%\u003c\/td\u003e\n\u003ctd data-start=\"2070\" data-end=\"2078\" data-col-size=\"sm\"\u003e0–95%\u003c\/td\u003e\n\u003ctd data-start=\"2078\" data-end=\"2087\" data-col-size=\"sm\"\u003e0–95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2088\" data-end=\"2131\"\u003e\n\u003ctd data-start=\"2088\" data-end=\"2115\" data-col-size=\"sm\"\u003eKerosene detection error\u003c\/td\u003e\n\u003ctd data-start=\"2115\" data-end=\"2120\" data-col-size=\"sm\"\u003e3%\u003c\/td\u003e\n\u003ctd data-start=\"2120\" data-end=\"2125\" data-col-size=\"sm\"\u003e3%\u003c\/td\u003e\n\u003ctd data-start=\"2125\" data-end=\"2131\" data-col-size=\"sm\"\u003e3%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2132\" data-end=\"2182\"\u003e\n\u003ctd data-start=\"2132\" data-end=\"2151\" data-col-size=\"sm\"\u003eMeasurement time\u003c\/td\u003e\n\u003ctd data-start=\"2151\" data-end=\"2161\" data-col-size=\"sm\"\u003e1–5 sec\u003c\/td\u003e\n\u003ctd data-start=\"2161\" data-end=\"2171\" data-col-size=\"sm\"\u003e1–5 sec\u003c\/td\u003e\n\u003ctd data-start=\"2171\" data-end=\"2182\" data-col-size=\"sm\"\u003e1–5 sec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003chr data-start=\"2184\" data-end=\"2187\"\u003e\n\u003ch2 data-start=\"2189\" data-end=\"2210\"\u003eAdditional Specs\u003c\/h2\u003e\n\u003cdiv class=\"_tableContainer_1rjym_1\"\u003e\n\u003cdiv class=\"group _tableWrapper_1rjym_13 flex w-fit flex-col-reverse\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"2212\" data-end=\"2950\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"2212\" data-end=\"2268\"\u003e\n\u003ctr data-start=\"2212\" data-end=\"2268\"\u003e\n\u003cth data-start=\"2212\" data-end=\"2228\" data-col-size=\"md\"\u003e\u003cstrong data-start=\"2214\" data-end=\"2227\"\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2228\" data-end=\"2241\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2230\" data-end=\"2240\"\u003eSX-150\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2241\" data-end=\"2254\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2243\" data-end=\"2253\"\u003eSX-250\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth data-start=\"2254\" data-end=\"2268\" data-col-size=\"sm\"\u003e\u003cstrong data-start=\"2256\" data-end=\"2266\"\u003eSX-300\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"2326\" data-end=\"2950\"\u003e\n\u003ctr data-start=\"2326\" data-end=\"2385\"\u003e\n\u003ctd data-start=\"2326\" data-end=\"2351\" data-col-size=\"md\"\u003eInstrument useful life\u003c\/td\u003e\n\u003ctd data-start=\"2351\" data-end=\"2362\" data-col-size=\"sm\"\u003e≥6 years\u003c\/td\u003e\n\u003ctd data-start=\"2362\" data-end=\"2373\" data-col-size=\"sm\"\u003e≥6 years\u003c\/td\u003e\n\u003ctd data-start=\"2373\" data-end=\"2385\" data-col-size=\"sm\"\u003e≥6 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2386\" data-end=\"2433\"\u003e\n\u003ctd data-start=\"2386\" data-end=\"2411\" data-col-size=\"md\"\u003ePower supply threshold\u003c\/td\u003e\n\u003ctd data-start=\"2411\" data-end=\"2418\" data-col-size=\"sm\"\u003e5.4V\u003c\/td\u003e\n\u003ctd data-start=\"2418\" data-end=\"2425\" data-col-size=\"sm\"\u003e5.4V\u003c\/td\u003e\n\u003ctd data-start=\"2425\" data-end=\"2433\" data-col-size=\"sm\"\u003e5.4V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2434\" data-end=\"2498\"\u003e\n\u003ctd data-start=\"2434\" data-end=\"2467\" data-col-size=\"md\"\u003eMotor oils clarity measurement\u003c\/td\u003e\n\u003ctd data-start=\"2467\" data-end=\"2477\" data-col-size=\"sm\"\u003e95–100%\u003c\/td\u003e\n\u003ctd data-start=\"2477\" data-end=\"2487\" data-col-size=\"sm\"\u003e95–100%\u003c\/td\u003e\n\u003ctd data-start=\"2487\" data-end=\"2498\" data-col-size=\"sm\"\u003e95–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2499\" data-end=\"2565\"\u003e\n\u003ctd data-start=\"2499\" data-end=\"2545\" data-col-size=\"md\"\u003eCircuit-breaker oil breakdown voltage range\u003c\/td\u003e\n\u003ctd data-start=\"2545\" data-end=\"2549\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2549\" data-end=\"2553\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2553\" data-end=\"2565\" data-col-size=\"sm\"\u003e5–100 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2566\" data-end=\"2614\"\u003e\n\u003ctd data-start=\"2566\" data-end=\"2598\" data-col-size=\"md\"\u003eBreakdown voltage error limit\u003c\/td\u003e\n\u003ctd data-start=\"2598\" data-end=\"2602\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2602\" data-end=\"2606\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2606\" data-end=\"2614\" data-col-size=\"sm\"\u003e1 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2615\" data-end=\"2667\"\u003e\n\u003ctd data-start=\"2615\" data-end=\"2649\" data-col-size=\"md\"\u003eBreakdown time difference limit\u003c\/td\u003e\n\u003ctd data-start=\"2649\" data-end=\"2653\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2653\" data-end=\"2657\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2657\" data-end=\"2667\" data-col-size=\"sm\"\u003e0.2 kV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2668\" data-end=\"2734\"\u003e\n\u003ctd data-start=\"2668\" data-end=\"2715\" data-col-size=\"md\"\u003eCircuit-breaker oil loss angle tangent range\u003c\/td\u003e\n\u003ctd data-start=\"2715\" data-end=\"2719\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2719\" data-end=\"2723\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2723\" data-end=\"2734\" data-col-size=\"sm\"\u003e0.01–5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2735\" data-end=\"2777\"\u003e\n\u003ctd data-start=\"2735\" data-end=\"2760\" data-col-size=\"md\"\u003eLoss angle error limit\u003c\/td\u003e\n\u003ctd data-start=\"2760\" data-end=\"2764\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2764\" data-end=\"2768\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2768\" data-end=\"2777\" data-col-size=\"sm\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2778\" data-end=\"2834\"\u003e\n\u003ctd data-start=\"2778\" data-end=\"2811\" data-col-size=\"md\"\u003eLoss angle parallel difference\u003c\/td\u003e\n\u003ctd data-start=\"2811\" data-end=\"2815\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2815\" data-end=\"2819\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2819\" data-end=\"2834\" data-col-size=\"sm\"\u003e0.001 Units\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2835\" data-end=\"2896\"\u003e\n\u003ctd data-start=\"2835\" data-end=\"2877\" data-col-size=\"md\"\u003eMechanical impurities measurement range\u003c\/td\u003e\n\u003ctd data-start=\"2877\" data-end=\"2881\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2881\" data-end=\"2885\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2885\" data-end=\"2896\" data-col-size=\"sm\"\u003e97–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2897\" data-end=\"2950\"\u003e\n\u003ctd data-start=\"2897\" data-end=\"2933\" data-col-size=\"md\"\u003eMechanical impurities error limit\u003c\/td\u003e\n\u003ctd data-start=\"2933\" data-end=\"2937\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2937\" data-end=\"2941\" data-col-size=\"sm\"\u003e–\u003c\/td\u003e\n\u003ctd data-start=\"2941\" data-end=\"2950\" data-col-size=\"sm\"\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eDownloads\u003c\/p\u003e\n\u003cp\u003eData Sheet \u003cstrong data-start=\"2230\" data-end=\"2240\"\u003eSX-150 \u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/SHATOX_SX-150_Portable_Octane_and_Cetane_Meter.pdf?v=1759131774\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eData Sheet \u003cstrong data-start=\"2230\" data-end=\"2240\"\u003eSX-250 \u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/SHATOX_SX-250_Portable_Octane_and_Cetane_Meter.pdf?v=1759131774\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eData Sheet \u003cstrong data-start=\"2230\" data-end=\"2240\"\u003eSX-300 \u003c\/strong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/SHATOX_SX-300_Portable_Octane_and_Cetane_Meter.pdf?v=1759131774\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e","brand":"SHATOX","offers":[{"title":"SX-150","offer_id":44584479523007,"sku":"SX-150","price":74610.0,"currency_code":"ZAR","in_stock":true},{"title":"SX-250","offer_id":44584479555775,"sku":null,"price":84440.0,"currency_code":"ZAR","in_stock":true},{"title":"SX-300","offer_id":44584479588543,"sku":null,"price":104100.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/H7afe9c91a71e44f1b6b4a64aed08d8d0z.jpg?v=1759132629"},{"product_id":"digital-pull-off-adhesion-tester-coating-bond-strength-meter-bgd-500-copy","title":"Digital Rotational Viscometer NDJ-1","description":"\u003ch3 data-start=\"649\" data-end=\"679\"\u003e\u003cstrong data-start=\"653\" data-end=\"677\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"680\" data-end=\"1044\"\u003eThe \u003cstrong data-start=\"684\" data-end=\"723\"\u003eNDJ-1 Digital Rotational Viscometer\u003c\/strong\u003e is a precision instrument designed for measuring fluid viscosity across a wide range—\u003cstrong data-start=\"809\" data-end=\"836\"\u003efrom 1 to 100,000 mPa·s\u003c\/strong\u003e. This lab-grade device is suitable for testing the flow characteristics of \u003cstrong data-start=\"912\" data-end=\"974\"\u003ecoatings, inks, resins, oils, food products, and adhesives\u003c\/strong\u003e, offering dependable performance in quality control and R\u0026amp;D settings.\u003c\/p\u003e\n\u003cp data-start=\"1046\" data-end=\"1399\"\u003eWith four standard rotors (\u003cstrong data-start=\"1073\" data-end=\"1085\"\u003e#1 to #4\u003c\/strong\u003e) and an optional \u003cstrong data-start=\"1103\" data-end=\"1115\"\u003e#0 rotor\u003c\/strong\u003e for ultra-low viscosity samples (0.1–100 mPa·s), the NDJ-1 provides \u003cstrong data-start=\"1184\" data-end=\"1211\"\u003emultiple speed settings\u003c\/strong\u003e (6, 12, 30, 60 rpm) for dynamic viscosity profiling. Once the measurement stabilizes, the unit \u003cstrong data-start=\"1307\" data-end=\"1340\"\u003eautomatically stops the rotor\u003c\/strong\u003e, ensuring accurate results with minimal user intervention.\u003c\/p\u003e\n\u003cp data-start=\"1401\" data-end=\"1687\"\u003eEquipped with \u003cstrong data-start=\"1415\" data-end=\"1432\"\u003eRS232 outputs\u003c\/strong\u003e for PC and printer connectivity, the NDJ-1 supports digital data collection and logging. Its compact, durable design and user-friendly interface make it an essential tool for labs, manufacturers, and production lines requiring reliable viscosity control.\u003c\/p\u003e\n\u003chr data-start=\"1689\" data-end=\"1692\"\u003e\n\u003ch3 data-start=\"1694\" data-end=\"1715\"\u003e\u003cstrong data-start=\"1698\" data-end=\"1715\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1717\" data-end=\"2155\"\u003e\n\u003cli data-start=\"1717\" data-end=\"1762\"\u003e\n\u003cp data-start=\"1719\" data-end=\"1762\"\u003eWide viscosity range: \u003cstrong data-start=\"1741\" data-end=\"1760\"\u003e1–100,000 mPa·s\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1763\" data-end=\"1850\"\u003e\n\u003cp data-start=\"1765\" data-end=\"1850\"\u003eComes with \u003cstrong data-start=\"1776\" data-end=\"1805\"\u003e4 standard rotors (#1–#4)\u003c\/strong\u003e; optional #0 rotor for ultra-low viscosity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1851\" data-end=\"1904\"\u003e\n\u003cp data-start=\"1853\" data-end=\"1904\"\u003e\u003cstrong data-start=\"1853\" data-end=\"1877\"\u003eAutomatic rotor stop\u003c\/strong\u003e after stable measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1905\" data-end=\"1947\"\u003e\n\u003cp data-start=\"1907\" data-end=\"1947\"\u003e\u003cstrong data-start=\"1907\" data-end=\"1926\"\u003e4-speed control\u003c\/strong\u003e: 6, 12, 30, 60 rpm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1948\" data-end=\"2011\"\u003e\n\u003cp data-start=\"1950\" data-end=\"2011\"\u003e\u003cstrong data-start=\"1950\" data-end=\"1968\"\u003eBuilt-in RS232\u003c\/strong\u003e interface for PC and printer connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2012\" data-end=\"2053\"\u003e\n\u003cp data-start=\"2014\" data-end=\"2053\"\u003eLCD digital display for live readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2054\" data-end=\"2098\"\u003e\n\u003cp data-start=\"2056\" data-end=\"2098\"\u003eCompact and lightweight for benchtop use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2099\" data-end=\"2155\"\u003e\n\u003cp data-start=\"2101\" data-end=\"2155\"\u003eSuitable for \u003cstrong data-start=\"2114\" data-end=\"2155\"\u003elabs, production, and QC environments\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2157\" data-end=\"2160\"\u003e\n\u003ch3 data-start=\"2162\" data-end=\"2195\"\u003e\u003cstrong data-start=\"2166\" data-end=\"2195\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2197\" data-end=\"2648\"\u003e\n\u003cli data-start=\"2197\" data-end=\"2217\"\u003e\n\u003cp data-start=\"2199\" data-end=\"2217\"\u003e\u003cstrong data-start=\"2199\" data-end=\"2208\"\u003eModel\u003c\/strong\u003e: NDJ-1\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2218\" data-end=\"2253\"\u003e\n\u003cp data-start=\"2220\" data-end=\"2253\"\u003e\u003cstrong data-start=\"2220\" data-end=\"2229\"\u003ePower\u003c\/strong\u003e: AC 110–240V \/ DC 12V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2254\" data-end=\"2292\"\u003e\n\u003cp data-start=\"2256\" data-end=\"2292\"\u003e\u003cstrong data-start=\"2256\" data-end=\"2275\"\u003eMeasuring Range\u003c\/strong\u003e: 1–1×10⁵ mPa·s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2293\" data-end=\"2365\"\u003e\n\u003cp data-start=\"2295\" data-end=\"2365\"\u003e\u003cstrong data-start=\"2295\" data-end=\"2305\"\u003eRotors\u003c\/strong\u003e: #1, #2, #3, #4 (Standard); Optional #0 for 0.1–100 mPa·s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2366\" data-end=\"2405\"\u003e\n\u003cp data-start=\"2368\" data-end=\"2405\"\u003e\u003cstrong data-start=\"2368\" data-end=\"2384\"\u003eRotor Speeds\u003c\/strong\u003e: 6, 12, 30, 60 rpm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2406\" data-end=\"2448\"\u003e\n\u003cp data-start=\"2408\" data-end=\"2448\"\u003e\u003cstrong data-start=\"2408\" data-end=\"2434\"\u003eSample Volume Required\u003c\/strong\u003e: 250–400 ml\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2449\" data-end=\"2470\"\u003e\n\u003cp data-start=\"2451\" data-end=\"2470\"\u003e\u003cstrong data-start=\"2451\" data-end=\"2463\"\u003eAccuracy\u003c\/strong\u003e: ±2%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2471\" data-end=\"2501\"\u003e\n\u003cp data-start=\"2473\" data-end=\"2501\"\u003e\u003cstrong data-start=\"2473\" data-end=\"2489\"\u003eRS232 for PC\u003c\/strong\u003e: Included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2502\" data-end=\"2537\"\u003e\n\u003cp data-start=\"2504\" data-end=\"2537\"\u003e\u003cstrong data-start=\"2504\" data-end=\"2525\"\u003eRS232 for Printer\u003c\/strong\u003e: Included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2538\" data-end=\"2582\"\u003e\n\u003cp data-start=\"2540\" data-end=\"2582\"\u003e\u003cstrong data-start=\"2540\" data-end=\"2563\"\u003eWorking Environment\u003c\/strong\u003e: 5–35°C, ≤80% RH\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2583\" data-end=\"2621\"\u003e\n\u003cp data-start=\"2585\" data-end=\"2621\"\u003e\u003cstrong data-start=\"2585\" data-end=\"2599\"\u003eDimensions\u003c\/strong\u003e: 415 × 335 × 370 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2622\" data-end=\"2648\"\u003e\n\u003cp data-start=\"2624\" data-end=\"2648\"\u003e\u003cstrong data-start=\"2624\" data-end=\"2638\"\u003eNet Weight\u003c\/strong\u003e: 4.6 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2650\" data-end=\"2653\"\u003e\n\u003ch3 data-start=\"2655\" data-end=\"2682\"\u003e\u003cstrong data-start=\"2659\" data-end=\"2682\"\u003eIndustries Used In:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2684\" data-end=\"2893\"\u003e\n\u003cli data-start=\"2684\" data-end=\"2706\"\u003e\n\u003cp data-start=\"2686\" data-end=\"2706\"\u003ePaint and coatings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2707\" data-end=\"2724\"\u003e\n\u003cp data-start=\"2709\" data-end=\"2724\"\u003ePrinting inks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2725\" data-end=\"2751\"\u003e\n\u003cp data-start=\"2727\" data-end=\"2751\"\u003eAdhesives and sealants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2752\" data-end=\"2792\"\u003e\n\u003cp data-start=\"2754\" data-end=\"2792\"\u003eCosmetics and personal care products\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2793\" data-end=\"2814\"\u003e\n\u003cp data-start=\"2795\" data-end=\"2814\"\u003eFood and beverage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2815\" data-end=\"2843\"\u003e\n\u003cp data-start=\"2817\" data-end=\"2843\"\u003ePetroleum and lubricants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2844\" data-end=\"2893\"\u003e\n\u003cp data-start=\"2846\" data-end=\"2893\"\u003eChemical R\u0026amp;D and quality control laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2895\" data-end=\"2898\"\u003e\n\u003ch3 data-start=\"2900\" data-end=\"2926\"\u003e\u003cstrong data-start=\"2904\" data-end=\"2926\"\u003eAlternative Names:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"2928\" data-end=\"3046\"\u003eRotational Viscometer\u003cbr data-start=\"2949\" data-end=\"2952\"\u003eDigital Viscosity Tester\u003cbr data-start=\"2976\" data-end=\"2979\"\u003eLab Viscosity Meter\u003cbr data-start=\"2998\" data-end=\"3001\"\u003ePaint Viscometer\u003cbr data-start=\"3017\" data-end=\"3020\"\u003eFluid Consistency Tester\u003c\/p\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\n\u003cp\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/2025Oriental_-28.pdf?v=1762382730\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e","brand":"Oriental Scientific","offers":[{"title":"Default Title","offer_id":44685536526527,"sku":"NDJ-1","price":10100.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/H7bac12cd798245c484ef0784add54d14H.jpg?v=1762382824"},{"product_id":"viscosity-meter-digital-rotational-viscometer-ndj-5s-ndj-8s","title":"Digital Rotational Viscometer NDJ-8S","description":"\u003ch3 data-start=\"647\" data-end=\"677\"\u003e\u003cstrong data-start=\"651\" data-end=\"675\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"678\" data-end=\"993\"\u003eThe \u003cstrong data-start=\"682\" data-end=\"722\"\u003eNDJ-8S Digital Rotational Viscometer\u003c\/strong\u003e is a precision instrument designed for accurate measurement of high-viscosity fluids in industrial and laboratory settings. With a broad measuring range of \u003cstrong data-start=\"879\" data-end=\"896\"\u003e1–2×10⁶ mPa·s\u003c\/strong\u003e and \u003cstrong data-start=\"901\" data-end=\"917\"\u003e±1% accuracy\u003c\/strong\u003e, it is ideal for testing adhesives, polymers, lubricants, paints, and more.\u003c\/p\u003e\n\u003cp data-start=\"995\" data-end=\"1240\"\u003eThis model features \u003cstrong data-start=\"1015\" data-end=\"1044\"\u003e8 selectable rotor speeds\u003c\/strong\u003e, digital display, and \u003cstrong data-start=\"1067\" data-end=\"1086\"\u003eRS232 interface\u003c\/strong\u003e for easy data logging to a PC or printer. It comes equipped with 4 standard rotors and supports an optional \u003cstrong data-start=\"1195\" data-end=\"1207\"\u003e#0 rotor\u003c\/strong\u003e for ultra-low viscosity fluids.\u003c\/p\u003e\n\u003cp data-start=\"1242\" data-end=\"1428\"\u003eThe \u003cstrong data-start=\"1246\" data-end=\"1289\"\u003eNDJ-8S also includes automatic scanning\u003c\/strong\u003e, an aluminum carrying case, and an \u003cstrong data-start=\"1325\" data-end=\"1356\"\u003eoptional temperature sensor \u003c\/strong\u003efor real-time temperature monitoring during viscosity testing.\u003c\/p\u003e\n\u003cp data-start=\"1430\" data-end=\"1571\"\u003eWhether for quality control, research, or production monitoring, the NDJ-8S offers reliable, repeatable results with user-friendly operation.\u003c\/p\u003e\n\u003chr data-start=\"1573\" data-end=\"1576\"\u003e\n\u003ch3 data-start=\"1578\" data-end=\"1599\"\u003e\u003cstrong data-start=\"1582\" data-end=\"1599\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1601\" data-end=\"2141\"\u003e\n\u003cli data-start=\"1601\" data-end=\"1642\"\u003e\n\u003cp data-start=\"1603\" data-end=\"1642\"\u003eWide viscosity range: \u003cstrong data-start=\"1625\" data-end=\"1642\"\u003e1–2×10⁶ mPa·s\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1643\" data-end=\"1679\"\u003e\n\u003cp data-start=\"1645\" data-end=\"1679\"\u003eHigh measurement accuracy: \u003cstrong data-start=\"1672\" data-end=\"1679\"\u003e±1%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1680\" data-end=\"1740\"\u003e\n\u003cp data-start=\"1682\" data-end=\"1740\"\u003e\u003cstrong data-start=\"1682\" data-end=\"1701\"\u003e8-speed control\u003c\/strong\u003e: 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1741\" data-end=\"1796\"\u003e\n\u003cp data-start=\"1743\" data-end=\"1796\"\u003eDigital LCD display with stable, real-time readings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1797\" data-end=\"1849\"\u003e\n\u003cp data-start=\"1799\" data-end=\"1849\"\u003eComes with 4 standard rotors: \u003cstrong data-start=\"1829\" data-end=\"1847\"\u003e#1, #2, #3, #4\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1850\" data-end=\"1925\"\u003e\n\u003cp data-start=\"1852\" data-end=\"1925\"\u003eOptional \u003cstrong data-start=\"1861\" data-end=\"1873\"\u003e#0 rotor\u003c\/strong\u003e available for 0.1–100 mPa·s (ultra-low viscosity)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1926\" data-end=\"1972\"\u003e\n\u003cp data-start=\"1928\" data-end=\"1972\"\u003e\u003cstrong data-start=\"1928\" data-end=\"1942\"\u003eRS232 port\u003c\/strong\u003e for PC\/printer connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1973\" data-end=\"2017\"\u003e\n\u003cp data-start=\"1975\" data-end=\"2017\"\u003e\u003cstrong data-start=\"1975\" data-end=\"2006\"\u003eAutomatic scanning function\u003c\/strong\u003e built-in\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2018\" data-end=\"2087\"\u003e\n\u003cp data-start=\"2020\" data-end=\"2087\"\u003eOptional \u003cstrong data-start=\"2029\" data-end=\"2051\"\u003etemperature sensor\u003c\/strong\u003e for real-time monitoring \u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2088\" data-end=\"2141\"\u003e\n\u003cp data-start=\"2090\" data-end=\"2141\"\u003ePacked in a durable aluminum box with foam interior\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2143\" data-end=\"2146\"\u003e\n\u003ch3 data-start=\"2148\" data-end=\"2181\"\u003e\u003cstrong data-start=\"2152\" data-end=\"2181\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2183\" data-end=\"2744\"\u003e\n\u003cli data-start=\"2183\" data-end=\"2204\"\u003e\n\u003cp data-start=\"2185\" data-end=\"2204\"\u003e\u003cstrong data-start=\"2185\" data-end=\"2194\"\u003eModel\u003c\/strong\u003e: NDJ-8S\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2205\" data-end=\"2243\"\u003e\n\u003cp data-start=\"2207\" data-end=\"2243\"\u003e\u003cstrong data-start=\"2207\" data-end=\"2226\"\u003eViscosity Range\u003c\/strong\u003e: 1–2×10⁶ mPa·s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2244\" data-end=\"2265\"\u003e\n\u003cp data-start=\"2246\" data-end=\"2265\"\u003e\u003cstrong data-start=\"2246\" data-end=\"2258\"\u003eAccuracy\u003c\/strong\u003e: ±1%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2266\" data-end=\"2323\"\u003e\n\u003cp data-start=\"2268\" data-end=\"2323\"\u003e\u003cstrong data-start=\"2268\" data-end=\"2284\"\u003eRotor Speeds\u003c\/strong\u003e: 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2324\" data-end=\"2363\"\u003e\n\u003cp data-start=\"2326\" data-end=\"2363\"\u003e\u003cstrong data-start=\"2326\" data-end=\"2345\"\u003eRotors Included\u003c\/strong\u003e: #1, #2, #3, #4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2364\" data-end=\"2418\"\u003e\n\u003cp data-start=\"2366\" data-end=\"2418\"\u003e\u003cstrong data-start=\"2366\" data-end=\"2384\"\u003eOptional Rotor\u003c\/strong\u003e: #0 (for 0.1–100 mPa·s samples)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2419\" data-end=\"2464\"\u003e\n\u003cp data-start=\"2421\" data-end=\"2464\"\u003e\u003cstrong data-start=\"2421\" data-end=\"2443\"\u003eTemperature Sensor\u003c\/strong\u003e: Optional (25 USD)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2465\" data-end=\"2509\"\u003e\n\u003cp data-start=\"2467\" data-end=\"2509\"\u003e\u003cstrong data-start=\"2467\" data-end=\"2483\"\u003ePower Supply\u003c\/strong\u003e: AC110–240V, DC12V \/ 5W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2510\" data-end=\"2560\"\u003e\n\u003cp data-start=\"2512\" data-end=\"2560\"\u003e\u003cstrong data-start=\"2512\" data-end=\"2535\"\u003eWorking Environment\u003c\/strong\u003e: 5–35°C, ≤80% humidity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2561\" data-end=\"2607\"\u003e\n\u003cp data-start=\"2563\" data-end=\"2607\"\u003e\u003cstrong data-start=\"2563\" data-end=\"2573\"\u003eOutput\u003c\/strong\u003e: RS232 (PC and printer support)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2608\" data-end=\"2639\"\u003e\n\u003cp data-start=\"2610\" data-end=\"2639\"\u003e\u003cstrong data-start=\"2610\" data-end=\"2627\"\u003eAuto Scanning\u003c\/strong\u003e: Included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2640\" data-end=\"2678\"\u003e\n\u003cp data-start=\"2642\" data-end=\"2678\"\u003e\u003cstrong data-start=\"2642\" data-end=\"2656\"\u003eDimensions\u003c\/strong\u003e: 370 × 325 × 280 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2679\" data-end=\"2705\"\u003e\n\u003cp data-start=\"2681\" data-end=\"2705\"\u003e\u003cstrong data-start=\"2681\" data-end=\"2695\"\u003eNet Weight\u003c\/strong\u003e: 5.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2706\" data-end=\"2744\"\u003e\n\u003cp data-start=\"2708\" data-end=\"2744\"\u003e\u003cstrong data-start=\"2708\" data-end=\"2721\"\u003ePackaging\u003c\/strong\u003e: Aluminum box + carton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2746\" data-end=\"2749\"\u003e\n\u003ch3 data-start=\"2751\" data-end=\"2778\"\u003e\u003cstrong data-start=\"2755\" data-end=\"2778\"\u003eIndustries Used In:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2780\" data-end=\"2972\"\u003e\n\u003cli data-start=\"2780\" data-end=\"2809\"\u003e\n\u003cp data-start=\"2782\" data-end=\"2809\"\u003ePaint, coatings, and inks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2810\" data-end=\"2836\"\u003e\n\u003cp data-start=\"2812\" data-end=\"2836\"\u003eAdhesives and sealants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2837\" data-end=\"2870\"\u003e\n\u003cp data-start=\"2839\" data-end=\"2870\"\u003eLubricants and grease testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2871\" data-end=\"2904\"\u003e\n\u003cp data-start=\"2873\" data-end=\"2904\"\u003ePharmaceuticals and cosmetics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2905\" data-end=\"2944\"\u003e\n\u003cp data-start=\"2907\" data-end=\"2944\"\u003eFood production and quality control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2945\" data-end=\"2972\"\u003e\n\u003cp data-start=\"2947\" data-end=\"2972\"\u003eChemical R\u0026amp;D laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2974\" data-end=\"2977\"\u003e\n\u003ch3 data-start=\"2979\" data-end=\"3005\"\u003e\u003cstrong data-start=\"2983\" data-end=\"3005\"\u003eAlternative Names:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3007\" data-end=\"3174\"\u003eDigital Rotational Viscometer\u003cbr data-start=\"3036\" data-end=\"3039\"\u003eHigh-Viscosity Fluid Tester\u003cbr data-start=\"3066\" data-end=\"3069\"\u003eViscosity Meter for Industrial Fluids\u003cbr data-start=\"3106\" data-end=\"3109\"\u003eRS232 Lab Viscometer\u003cbr data-start=\"3129\" data-end=\"3132\"\u003ePrecision Viscosity Measurement Instrument\u003c\/p\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\n\u003cp\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/2025Oriental_-28.pdf?v=1762382730\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e","brand":"Oriental Scientific","offers":[{"title":"Standard model","offer_id":44755661979839,"sku":"NDJ-8S","price":17210.0,"currency_code":"ZAR","in_stock":true},{"title":"Standard Model with 0# Rotor \u0026 Temperature Sensor","offer_id":44755662012607,"sku":"NDJ-8S-2","price":18500.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/H392889f51a8e4593867a3f56c8c6f129C.png?v=1762383178"},{"product_id":"viscosity-meter-digital-rotational-viscometer-ndj-8s-copy","title":"Digital Rotational Viscometer LV-C","description":"\u003ch3 data-start=\"676\" data-end=\"706\"\u003e\u003cstrong data-start=\"680\" data-end=\"704\"\u003eProduct Description:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"707\" data-end=\"1034\"\u003eThe \u003cstrong data-start=\"711\" data-end=\"749\"\u003eLV-C Digital Rotational Viscometer\u003c\/strong\u003e is a high-end viscosity measurement instrument designed for professional labs, research facilities, and production environments. With a wide measuring range of \u003cstrong data-start=\"910\" data-end=\"925\"\u003e6–1×10⁶ cps\u003c\/strong\u003e, this model is suitable for testing everything from low-viscosity liquids to high-viscosity gels and pastes.\u003c\/p\u003e\n\u003cp data-start=\"1036\" data-end=\"1249\"\u003eThe LV-C features a \u003cstrong data-start=\"1056\" data-end=\"1084\"\u003e3-inch TFT color display\u003c\/strong\u003e, real-time digital readings, and \u003cstrong data-start=\"1118\" data-end=\"1153\"\u003estepless rotor speed adjustment\u003c\/strong\u003e from \u003cstrong data-start=\"1159\" data-end=\"1177\"\u003e0.1 to 200 rpm\u003c\/strong\u003e, allowing for fine-tuned control across a wide variety of sample types.\u003c\/p\u003e\n\u003cp data-start=\"1251\" data-end=\"1519\"\u003eIt includes \u003cstrong data-start=\"1263\" data-end=\"1292\"\u003e4 standard rotors (#1–#4)\u003c\/strong\u003e with an optional \u003cstrong data-start=\"1310\" data-end=\"1322\"\u003e#0 rotor\u003c\/strong\u003e for ultra-low viscosity samples. A \u003cstrong data-start=\"1358\" data-end=\"1380\"\u003etemperature sensor\u003c\/strong\u003e is also included for accurate thermal readings during testing. The RS232 interface enables data output for lab records or printer logging.\u003c\/p\u003e\n\u003cp data-start=\"1521\" data-end=\"1685\"\u003eWhether you work in R\u0026amp;D, quality control, or manufacturing, the LV-C provides fast, accurate, and repeatable viscosity measurements with modern digital convenience.\u003c\/p\u003e\n\u003chr data-start=\"1687\" data-end=\"1690\"\u003e\n\u003ch3 data-start=\"1692\" data-end=\"1713\"\u003e\u003cstrong data-start=\"1696\" data-end=\"1713\"\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1715\" data-end=\"2234\"\u003e\n\u003cli data-start=\"1715\" data-end=\"1761\"\u003e\n\u003cp data-start=\"1717\" data-end=\"1761\"\u003eWide measurement range: \u003cstrong data-start=\"1741\" data-end=\"1759\"\u003e6 to 1×10⁶ cps\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1762\" data-end=\"1805\"\u003e\n\u003cp data-start=\"1764\" data-end=\"1805\"\u003e\u003cstrong data-start=\"1764\" data-end=\"1790\"\u003eStepless speed control\u003c\/strong\u003e: 0.1–200 rpm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1806\" data-end=\"1857\"\u003e\n\u003cp data-start=\"1808\" data-end=\"1857\"\u003eHigh accuracy: \u003cstrong data-start=\"1823\" data-end=\"1830\"\u003e±1%\u003c\/strong\u003e, repeatability \u003cstrong data-start=\"1846\" data-end=\"1855\"\u003e±0.5%\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1858\" data-end=\"1898\"\u003e\n\u003cp data-start=\"1860\" data-end=\"1898\"\u003e\u003cstrong data-start=\"1860\" data-end=\"1884\"\u003eViscosity resolution\u003c\/strong\u003e: 0.01 mPa·s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1899\" data-end=\"1957\"\u003e\n\u003cp data-start=\"1901\" data-end=\"1957\"\u003e\u003cstrong data-start=\"1901\" data-end=\"1934\"\u003e3-inch full-color TFT display\u003c\/strong\u003e for easy readability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"1958\" data-end=\"1999\"\u003e\n\u003cp data-start=\"1960\" data-end=\"1999\"\u003e\u003cstrong data-start=\"1960\" data-end=\"1981\"\u003e4 rotors included\u003c\/strong\u003e: #1, #2, #3, #4\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2000\" data-end=\"2065\"\u003e\n\u003cp data-start=\"2002\" data-end=\"2065\"\u003eOptional \u003cstrong data-start=\"2011\" data-end=\"2023\"\u003e#0 rotor\u003c\/strong\u003e for ultra-low viscosity (0.1–100 mPa·s)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2066\" data-end=\"2121\"\u003e\n\u003cp data-start=\"2068\" data-end=\"2121\"\u003e\u003cstrong data-start=\"2068\" data-end=\"2091\"\u003eBuilt-in RS232 port\u003c\/strong\u003e for PC\/printer connectivity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2122\" data-end=\"2175\"\u003e\n\u003cp data-start=\"2124\" data-end=\"2175\"\u003e\u003cstrong data-start=\"2124\" data-end=\"2155\"\u003eTemperature sensor included\u003c\/strong\u003e (±0.1°C accuracy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2176\" data-end=\"2234\"\u003e\n\u003cp data-start=\"2178\" data-end=\"2234\"\u003eComes in a \u003cstrong data-start=\"2189\" data-end=\"2234\"\u003edurable aluminum box with protective foam\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2236\" data-end=\"2239\"\u003e\n\u003ch3 data-start=\"2241\" data-end=\"2274\"\u003e\u003cstrong data-start=\"2245\" data-end=\"2274\"\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2276\" data-end=\"2857\"\u003e\n\u003cli data-start=\"2276\" data-end=\"2295\"\u003e\n\u003cp data-start=\"2278\" data-end=\"2295\"\u003e\u003cstrong data-start=\"2278\" data-end=\"2287\"\u003eModel\u003c\/strong\u003e: LV-C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2296\" data-end=\"2341\"\u003e\n\u003cp data-start=\"2298\" data-end=\"2341\"\u003e\u003cstrong data-start=\"2298\" data-end=\"2309\"\u003eDisplay\u003c\/strong\u003e: 3-inch TFT full-color screen\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2342\" data-end=\"2378\"\u003e\n\u003cp data-start=\"2344\" data-end=\"2378\"\u003e\u003cstrong data-start=\"2344\" data-end=\"2363\"\u003eMeasuring Range\u003c\/strong\u003e: 6–1×10⁶ cps\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2379\" data-end=\"2420\"\u003e\n\u003cp data-start=\"2381\" data-end=\"2420\"\u003e\u003cstrong data-start=\"2381\" data-end=\"2406\"\u003eViscosity Readability\u003c\/strong\u003e: 0.01 mPa·s\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2421\" data-end=\"2442\"\u003e\n\u003cp data-start=\"2423\" data-end=\"2442\"\u003e\u003cstrong data-start=\"2423\" data-end=\"2435\"\u003eAccuracy\u003c\/strong\u003e: ±1%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2443\" data-end=\"2471\"\u003e\n\u003cp data-start=\"2445\" data-end=\"2471\"\u003e\u003cstrong data-start=\"2445\" data-end=\"2462\"\u003eRepeatability\u003c\/strong\u003e: ±0.5%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2472\" data-end=\"2515\"\u003e\n\u003cp data-start=\"2474\" data-end=\"2515\"\u003e\u003cstrong data-start=\"2474\" data-end=\"2489\"\u003eRotor Speed\u003c\/strong\u003e: 0.1–200 rpm (stepless)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2516\" data-end=\"2581\"\u003e\n\u003cp data-start=\"2518\" data-end=\"2581\"\u003e\u003cstrong data-start=\"2518\" data-end=\"2533\"\u003eRotor Types\u003c\/strong\u003e: #1, #2, #3, #4 (standard); optional #0 rotor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2582\" data-end=\"2636\"\u003e\n\u003cp data-start=\"2584\" data-end=\"2636\"\u003e\u003cstrong data-start=\"2584\" data-end=\"2606\"\u003eTemperature Sensor\u003c\/strong\u003e: Included (±0.1°C accuracy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2637\" data-end=\"2679\"\u003e\n\u003cp data-start=\"2639\" data-end=\"2679\"\u003e\u003cstrong data-start=\"2639\" data-end=\"2655\"\u003ePower Supply\u003c\/strong\u003e: AC110–240V DV5V \/ 5W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2680\" data-end=\"2710\"\u003e\n\u003cp data-start=\"2682\" data-end=\"2710\"\u003e\u003cstrong data-start=\"2682\" data-end=\"2698\"\u003eRS232 Output\u003c\/strong\u003e: Included\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2711\" data-end=\"2761\"\u003e\n\u003cp data-start=\"2713\" data-end=\"2761\"\u003e\u003cstrong data-start=\"2713\" data-end=\"2736\"\u003eWorking Environment\u003c\/strong\u003e: 5–40°C, ≤80% humidity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2762\" data-end=\"2797\"\u003e\n\u003cp data-start=\"2764\" data-end=\"2797\"\u003e\u003cstrong data-start=\"2764\" data-end=\"2778\"\u003eDimensions\u003c\/strong\u003e: 38 × 32 × 29 cm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2798\" data-end=\"2820\"\u003e\n\u003cp data-start=\"2800\" data-end=\"2820\"\u003e\u003cstrong data-start=\"2800\" data-end=\"2810\"\u003eWeight\u003c\/strong\u003e: 6.0 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2821\" data-end=\"2857\"\u003e\n\u003cp data-start=\"2823\" data-end=\"2857\"\u003e\u003cstrong data-start=\"2823\" data-end=\"2834\"\u003ePacking\u003c\/strong\u003e: Aluminum box + carton\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"2859\" data-end=\"2862\"\u003e\n\u003ch3 data-start=\"2864\" data-end=\"2891\"\u003e\u003cstrong data-start=\"2868\" data-end=\"2891\"\u003eIndustries Used In:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2893\" data-end=\"3074\"\u003e\n\u003cli data-start=\"2893\" data-end=\"2915\"\u003e\n\u003cp data-start=\"2895\" data-end=\"2915\"\u003ePaint and coatings\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2916\" data-end=\"2942\"\u003e\n\u003cp data-start=\"2918\" data-end=\"2942\"\u003eLubricants and greases\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2943\" data-end=\"2974\"\u003e\n\u003cp data-start=\"2945\" data-end=\"2974\"\u003eCosmetics and personal care\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"2975\" data-end=\"3001\"\u003e\n\u003cp data-start=\"2977\" data-end=\"3001\"\u003eAdhesives and sealants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3002\" data-end=\"3021\"\u003e\n\u003cp data-start=\"3004\" data-end=\"3021\"\u003ePharmaceuticals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3022\" data-end=\"3046\"\u003e\n\u003cp data-start=\"3024\" data-end=\"3046\"\u003eFood and beverage QC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli data-start=\"3047\" data-end=\"3074\"\u003e\n\u003cp data-start=\"3049\" data-end=\"3074\"\u003eChemical R\u0026amp;D laboratories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"3076\" data-end=\"3079\"\u003e\n\u003ch3 data-start=\"3081\" data-end=\"3107\"\u003e\u003cstrong data-start=\"3085\" data-end=\"3107\"\u003eAlternative Names:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp data-start=\"3109\" data-end=\"3254\"\u003eHigh-Accuracy Viscometer\u003cbr data-start=\"3133\" data-end=\"3136\"\u003eDigital Lab Viscometer\u003cbr data-start=\"3158\" data-end=\"3161\"\u003eTFT Display Viscosity Meter\u003cbr data-start=\"3188\" data-end=\"3191\"\u003eRotational Viscosity Tester\u003cbr data-start=\"3218\" data-end=\"3221\"\u003eAdvanced Fluid Consistency Tester\u003c\/p\u003e\n\u003ch6\u003eDownloads\u003c\/h6\u003e\n\u003cp\u003eData Sheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/2025Oriental_-28.pdf?v=1762382730\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e","brand":"Oriental Scientific","offers":[{"title":"Default Title","offer_id":44685565231295,"sku":"LV-C","price":28230.0,"currency_code":"ZAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0623\/8299\/7695\/files\/H05b4c50a624b439c81e2c29d5eb74277o.jpg?v=1762383389"}],"url":"https:\/\/inspectiontools.co.za\/collections\/fuel-oil-industrial-chemical-analysis.oembed","provider":"Inspection Tool Specialists","version":"1.0","type":"link"}